LUMEL
The area of RPL1 application includes:
• electric furnaces and drying structures, especially industrial furnaces and tunnel cap, furnaces for annealing and brazing, and founder crucible furnaces, drying ovens, furnaces with quenching in salt baths
• mechanical engineering equipment, aggregates and extruders for plastics processing, winding machines and tempering springs, spot welding and linear
• production of glass and glazing, plant and equipment for drying in the infrared and ultraviolet, vats for melting glass and heating trays for forming glass furnaces
• chemical and petroleum industry; radiators lining piping, wiring warming
Features:
• For power control of resistive and resistive load (transformer connected to resistive load or to rectifier circuit)
• Control mode: on/off (similar to solid state relay), pulse, phase
• Amplification of input control signal (SPAN)
• Limitation of load current
• Overload protection
• Signalization of exceeding the maximum temperature of radiator
• Control of 3-phase load (requires two RPL1 controller units)
External dimensions:
135 x 201 x 199 mm
135 x 231 x 199 mm (execution with fan)
compatible with the category of operational use AC-51 acc. to EN 60947-4-3
Dimensions | 135 x 201 x 199 mm |
---|---|
Output | Maximal output current 25 A |
Supply voltage | 340...400...440 V a.c |
Temperature operational max | 40 °C |
Temperature operational min | 0 °C |
Weight | 4,5 kg |
The area of RPL1 application includes:
• electric furnaces and drying structures, especially industrial furnaces and tunnel cap, furnaces for annealing and brazing, and founder crucible furnaces, drying ovens, furnaces with quenching in salt baths
• mechanical engineering equipment, aggregates and extruders for plastics processing, winding machines and tempering springs, spot welding and linear
• production of glass and glazing, plant and equipment for drying in the infrared and ultraviolet, vats for melting glass and heating trays for forming glass furnaces
• chemical and petroleum industry; radiators lining piping, wiring warming
Features:
• For power control of resistive and resistive load (transformer connected to resistive load or to rectifier circuit)
• Control mode: on/off (similar to solid state relay), pulse, phase
• Amplification of input control signal (SPAN)
• Limitation of load current
• Overload protection
• Signalization of exceeding the maximum temperature of radiator
• Control of 3-phase load (requires two RPL1 controller units)
External dimensions:
135 x 201 x 199 mm
135 x 231 x 199 mm (execution with fan)
compatible with the category of operational use AC-51 acc. to EN 60947-4-3
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Output | Supply voltage | Price | ||
---|---|---|---|---|---|
LUMEL RPL1 PWR CONT (PH) 25A 400VAC
Art:
RPL111200E0
Copied
|
Maximal output current 25 A
|
340...400...440 V a.c
|
| ||
LUMEL RPL1 PWR CONT (PH) 70A 230VAC
Art:
RPL113100E0
Copied
|
Maximal output current 70A
|
195...230...253 V a.c.
|
|
Select a variant in the list
If you need any help, you can contact us in one of the following ways: