General Data |
|
---|---|
Thread Size (G) | PG 16 |
Inner thread size | M25 |
IP class | IP 66 / IP 68 |
Dimensions |
|
Inner thread pitch | 1,5 mm |
Thread length | 6 mm |
Height (H) | 11,5 mm |
Spanner width (AF) | 30 mm |
Materials |
|
Material | Nickel-plated brass |
Materials O-ring | FPM |
Temperature range | -60°C ... +100°C |
Approvals |
|
Approvals | CE, DNV, EX, IECEx |
*Invisible Heading* |
|
---|---|
Test standard | IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31 |
Ex zones | Gas 1 and 2 / dust 21 and 22 |
Ex-Zone gas | II 2G Ex eb IIC Gb |
EX-zone dust | II 2D Ex tb IIIC Db |
IECEx certificate | IECEx SEV 15.0018 |
Certificate | SEV 15 ATEX 0151 |
Additional Data |
|
Pack size | 25 |
Country of origin | CH |
Tariff code | 74199949 |
Weight | 41,56 g |
The smallest logic controller by Crouzet is now 20% off for a limited time only! A powerhouse packed into just 17.5mm! Efficiency, adaptability, and seamless integration with free software.
Do you require signalling devices and beacons in your production process? Download our latest whitepaper!
Here, our customer requires control boxes for electricity metering systems. We leveraged our expertise to deliver easy-to-install, ready-to-use assemblies. We look forward to creating more of these bespoke control boxes for our customer.
This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Thread Size (G) | Inner thread size | IP class | Thread pitch | Inner thread pitch | Thread length | Height (H) | Spanner width (AF) | Diameter | Allen key size | Material | Materials O-ring | Material membrane | Temperature range | Approvals | Test standard | Ex-Zone gas | EX-zone dust | IECEx certificate | Certificate | Pack size | Country of origin | Tariff code | Weight | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]()
Locking screw NPB, Ex d IIC, M12
Art:
8710.12
Copied
|
M12
|
|
IP 68 (30 bar)
|
1,5
|
|
15 mm
|
5 mm
|
15 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-40°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-1 / IEC EN 60079-31
|
II 2G Ex db eb IIC
|
II 2D Ex ta IIC
|
IECEx PTB 12.0056
|
PTB 00 ATEX 1059
|
10
|
CH
|
74199949
|
18,6 g
|
| ||
![]()
Locking screw NPB, Ex d IIC, M16
Art:
8710.17
Copied
|
M16
|
|
IP 68 (30 bar)
|
1,5
|
|
15 mm
|
6 mm
|
18 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-40°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-1 / IEC EN 60079-31
|
II 2G Ex db eb IIC
|
II 2D Ex ta IIC
|
IECEx PTB 12.0056
|
PTB 00 ATEX 1059
|
10
|
CH
|
74199949
|
26,1 g
|
| ||
![]()
Locking screw NPB, Ex d IIC, M20
Art:
8710.20
Copied
|
M20
|
|
IP 68 (30 bar)
|
1,5
|
|
15 mm
|
8 mm
|
24 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-40°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-1 / IEC EN 60079-31
|
II 2G Ex db eb IIC
|
II 2D Ex ta IIC
|
IECEx PTB 12.0056
|
PTB 00 ATEX 1059
|
10
|
CH
|
74199949
|
49,8 g
|
| ||
![]()
Locking screw NPB, Ex d IIC, M25
Art:
8710.25
Copied
|
M25
|
|
IP 68 (30 bar)
|
1,5
|
|
15 mm
|
10 mm
|
30 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-40°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-1 / IEC EN 60079-31
|
II 2G Ex db eb IIC
|
II 2D Ex ta IIC
|
IECEx PTB 12.0056
|
PTB 00 ATEX 1059
|
10
|
CH
|
74199949
|
77,1 g
|
| ||
![]()
Locking screw NPB, Ex d IIC, M32
Art:
8710.32
Copied
|
M32
|
|
IP 68 (30 bar)
|
1,5
|
|
15 mm
|
12 mm
|
36 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-40°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-1 / IEC EN 60079-31
|
II 2G Ex db eb IIC
|
II 2D Ex ta IIC
|
IECEx PTB 12.0056
|
PTB 00 ATEX 1059
|
10
|
CH
|
74199949
|
132,2 g
|
| ||
![]()
Locking screw NPB, Ex d IIC, M40
Art:
8710.40
Copied
|
M40
|
|
IP 68 (30 bar)
|
1,5
|
|
15 mm
|
12 mm
|
46 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-40°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-1 / IEC EN 60079-31
|
II 2G Ex db eb IIC
|
II 2D Ex ta IIC
|
IECEx PTB 12.0056
|
PTB 00 ATEX 1059
|
10
|
CH
|
74199949
|
207 g
|
| ||
![]()
Locking screw NPB, Ex d IIC, M50
Art:
8710.50
Copied
|
M50
|
|
IP 68 (30 bar)
|
1,5
|
|
15 mm
|
12 mm
|
55 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-40°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-1 / IEC EN 60079-31
|
II 2G Ex db eb IIC
|
II 2D Ex ta IIC
|
IECEx PTB 12.0056
|
PTB 00 ATEX 1059
|
10
|
CH
|
74199949
|
270,3 g
|
| ||
![]()
Locking screw NPB, Ex d IIC, M63
Art:
8710.63
Copied
|
M63
|
|
IP 68 (30 bar)
|
1,5
|
|
15 mm
|
12 mm
|
70 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-40°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-1 / IEC EN 60079-31
|
II 2G Ex db eb IIC
|
II 2D Ex ta IIC
|
IECEx PTB 12.0056
|
PTB 00 ATEX 1059
|
10
|
CH
|
74199949
|
401,6 g
|
| ||
![]()
Locking screw NPB, Ex d IIC, Pg 7
Art:
8710.07
Copied
|
PG 7
|
|
IP 68 (30 bar)
|
|
|
10,5 mm
|
6,4 mm
|
16 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-40°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-1 / IEC EN 60079-31
|
II 2G Ex db eb IIC
|
II 2D Ex ta IIC
|
IECEx PTB 12.0056
|
PTB 00 ATEX 1059
|
10
|
CH
|
74199949
|
19 g
|
| ||
![]()
Locking screw NPB, Ex d IIC, Pg 9
Art:
8710.09
Copied
|
PG 9
|
|
IP 68 (30 bar)
|
|
|
12 mm
|
7,5 mm
|
18 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-40°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-1 / IEC EN 60079-31
|
II 2G Ex db eb IIC
|
II 2D Ex ta IIC
|
IECEx PTB 12.0056
|
PTB 00 ATEX 1059
|
10
|
CH
|
74199949
|
24,3 g
|
| ||
![]()
Locking screw NPB, Ex d IIC, Pg 11
Art:
8710.11
Copied
|
PG 11
|
|
IP 68 (30 bar)
|
|
|
12 mm
|
8,8 mm
|
21 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-40°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-1 / IEC EN 60079-31
|
II 2G Ex db eb IIC
|
II 2D Ex ta IIC
|
IECEx PTB 12.0056
|
PTB 00 ATEX 1059
|
10
|
CH
|
74199949
|
39,85 g
|
| ||
![]()
Locking screw NPB, Ex d IIC, Pg 13
Art:
8710.13
Copied
|
PG 13
|
|
IP 68 (30 bar)
|
|
|
14 mm
|
10 mm
|
24 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-40°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-1 / IEC EN 60079-31
|
II 2G Ex db eb IIC
|
II 2D Ex ta IIC
|
IECEx PTB 12.0056
|
PTB 00 ATEX 1059
|
10
|
CH
|
74199949
|
55 g
|
| ||
![]()
Locking screw NPB, Ex d IIC, Pg 16
Art:
8710.16
Copied
|
PG 16
|
|
IP 68 (30 bar)
|
|
|
14 mm
|
11,5 mm
|
27 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-40°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-1 / IEC EN 60079-31
|
II 2G Ex db eb IIC
|
II 2D Ex ta IIC
|
IECEx PTB 12.0056
|
PTB 00 ATEX 1059
|
10
|
CH
|
74199949
|
78,84 g
|
| ||
![]()
Locking screw NPB, Ex d IIC, Pg 21
Art:
8710.21
Copied
|
PG 21
|
|
IP 68 (30 bar)
|
|
|
16 mm
|
14 mm
|
32 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-40°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-1 / IEC EN 60079-31
|
II 2G Ex db eb IIC
|
II 2D Ex ta IIC
|
IECEx PTB 12.0056
|
PTB 00 ATEX 1059
|
10
|
CH
|
74199949
|
140,3 g
|
| ||
![]()
Locking screw NPB, Ex d IIC, Pg 29
Art:
8710.29
Copied
|
PG 29
|
|
IP 68 (30 bar)
|
|
|
17 mm
|
17 mm
|
41 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-40°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-1 / IEC EN 60079-31
|
II 2G Ex db eb IIC
|
II 2D Ex ta IIC
|
IECEx PTB 12.0056
|
PTB 00 ATEX 1059
|
10
|
CH
|
74199949
|
242,9 g
|
| ||
![]()
Locking screw NPB, Ex d IIC, Pg 36
Art:
8710.36
Copied
|
PG 36
|
|
IP 68 (30 bar)
|
|
|
17 mm
|
22,5 mm
|
55 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-40°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-1 / IEC EN 60079-31
|
II 2G Ex db eb IIC
|
II 2D Ex ta IIC
|
IECEx PTB 12.0056
|
PTB 00 ATEX 1059
|
10
|
CH
|
74199949
|
501,7 g
|
| ||
![]()
Locking screw NPB, Ex e II, M8
Art:
EX8708.08
Copied
|
M8
|
|
IP 66 / IP 68
|
1,25
|
|
5 mm
|
3 mm
|
|
10 mm
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
1,84 g
|
| ||
![]()
Locking screw NPB, Ex e II, M10
Art:
EX8710.08
Copied
|
M10
|
|
IP 66 / IP 68
|
1,5
|
|
5 mm
|
3 mm
|
|
12 mm
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
2,74 g
|
| ||
![]()
Locking screw NPB, Ex e II, M12
Art:
EX8712.08
Copied
|
M12
|
|
IP 66 / IP 68
|
1,5
|
|
5 mm
|
3 mm
|
|
14 mm
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
3,94 g
|
| ||
![]()
Locking screw NPB, Ex e II, M16
Art:
EX8717.08
Copied
|
M16
|
|
IP 66 / IP 68
|
1,5
|
|
5 mm
|
3 mm
|
|
19 mm
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
7,06 g
|
| ||
![]()
Locking screw NPB, Ex e II, M20
Art:
EX8720.08
Copied
|
M20
|
|
IP 66 / IP 68
|
1,5
|
|
6 mm
|
3 mm
|
|
24 mm
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
25
|
CH
|
74199949
|
11,72 g
|
| ||
![]()
Locking screw NPB, Ex e II, M25
Art:
EX8725.08
Copied
|
M25
|
|
IP 66 / IP 68
|
1,5
|
|
7 mm
|
4 mm
|
|
28 mm
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
25
|
CH
|
74199949
|
18,2 g
|
| ||
![]()
Locking screw NPB, Ex e II, M32
Art:
EX8732.08
Copied
|
M32
|
|
IP 66 / IP 68
|
1,5
|
|
8 mm
|
4 mm
|
|
35 mm
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
10
|
CH
|
74199949
|
29 g
|
| ||
![]()
Locking screw NPB, Ex e II, M40
Art:
EX8740.08
Copied
|
M40
|
|
IP 66 / IP 68
|
1,5
|
|
8 mm
|
6 mm
|
|
45 mm
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
10
|
CH
|
74199949
|
50 g
|
| ||
![]()
Locking screw NPB, Ex e II, M50
Art:
EX8750.08
Copied
|
M50
|
|
IP 66 / IP 68
|
1,5
|
|
9 mm
|
6 mm
|
|
55 mm
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
10
|
CH
|
74199949
|
79 g
|
| ||
![]()
Locking screw NPB, Ex e II, M63
Art:
EX8763.08
Copied
|
M63
|
|
IP 66 / IP 68
|
1,5
|
|
10 mm
|
6 mm
|
|
70 mm
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
10
|
CH
|
74199949
|
135,1 g
|
| ||
![]()
Locking screw NPB, Ex e II, Pg 7
Art:
EX8707.08
Copied
|
PG 7
|
|
IP 66 / IP 68
|
|
|
5 mm
|
3 mm
|
|
14 mm
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
4,36 g
|
| ||
![]()
Locking screw NPB, Ex e II, Pg 9
Art:
EX8709.08
Copied
|
PG 9
|
|
IP 66 / IP 68
|
|
|
6 mm
|
3 mm
|
|
17 mm
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
6,56 g
|
| ||
![]()
Locking screw NPB, Ex e II, Pg 11
Art:
EX8711.08
Copied
|
PG 11
|
|
IP 66 / IP 68
|
|
|
6 mm
|
3 mm
|
|
20 mm
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
9,56 g
|
| ||
![]()
Locking screw NPB, Ex e II, Pg 13
Art:
EX8713.08
Copied
|
PG 13
|
|
IP 66 / IP 68
|
|
|
6,5 mm
|
3 mm
|
|
22 mm
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
11,66 g
|
| ||
![]()
Locking screw NPB, Ex e II, Pg 16
Art:
EX8716.08
Copied
|
PG 16
|
|
IP 66 / IP 68
|
|
|
6,5 mm
|
3 mm
|
|
24 mm
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
13,86 g
|
| ||
![]()
Locking screw NPB, Ex e II, Pg 21
Art:
EX8721.08
Copied
|
PG 21
|
|
IP 66 / IP 68
|
|
|
7 mm
|
4 mm
|
|
30 mm
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
10
|
CH
|
74199949
|
26,8 g
|
| ||
![]()
Locking screw NPB, Ex e II, Pg 29
Art:
EX8729.08
Copied
|
PG 29
|
|
IP 66 / IP 68
|
|
|
8 mm
|
4 mm
|
|
39 mm
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
10
|
CH
|
74199949
|
41,6 g
|
| ||
![]()
Locking screw NPB, Ex e II, Pg 36
Art:
EX8736.08
Copied
|
PG 36
|
|
IP 66 / IP 68
|
|
|
9 mm
|
6 mm
|
|
50 mm
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
10
|
CH
|
74199949
|
88,37 g
|
| ||
![]()
Locking screw NPB, Ex e II, Pg 48
Art:
EX8748.08
Copied
|
PG 48
|
|
IP 66 / IP 68
|
|
|
10 mm
|
6 mm
|
|
65 mm
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
10
|
CH
|
74199949
|
152,7 g
|
| ||
![]()
Locking screw synthetic, Ex e II, M12
Art:
8841.12
Copied
|
M12
|
|
IP 68
|
1,5
|
|
8,5 mm
|
13 mm
|
15 mm
|
|
6 mm
|
Polyamide
|
NBR
|
|
-20°C ... +90°C
|
CE, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx BVS 07.0021
|
DMT 03 ATEX E 049
|
100
|
|
|
|
| ||
![]()
Locking screw synthetic, Ex e II, M16
Art:
8841.17
Copied
|
M16
|
|
IP 68
|
1,5
|
|
8,5 mm
|
13 mm
|
19 mm
|
|
8 mm
|
Polyamide
|
NBR
|
|
-20°C ... +90°C
|
CE, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx BVS 07.0021
|
DMT 03 ATEX E 049
|
100
|
|
|
|
| ||
![]()
Locking screw synthetic, Ex e II, M20
Art:
8841.20
Copied
|
M20
|
|
IP 68
|
1,5
|
|
9 mm
|
14,5 mm
|
24 mm
|
|
8 mm
|
Polyamide
|
NBR
|
|
-20°C ... +90°C
|
CE, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx BVS 07.0021
|
DMT 03 ATEX E 049
|
100
|
|
|
|
| ||
![]()
Locking screw synthetic, Ex e II, M25
Art:
8841.25
Copied
|
M25
|
|
IP 68
|
1,5
|
|
10,5 mm
|
16 mm
|
28 mm
|
|
8 mm
|
Polyamide
|
NBR
|
|
-20°C ... +90°C
|
CE, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx BVS 07.0021
|
DMT 03 ATEX E 049
|
100
|
|
|
|
| ||
![]()
Locking screw synthetic, Ex e II, M32
Art:
8841.32
Copied
|
M32
|
|
IP 68
|
1,5
|
|
11,5 mm
|
17,5 mm
|
36 mm
|
|
8 mm
|
Polyamide
|
NBR
|
|
-20°C ... +90°C
|
CE, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx BVS 07.0021
|
DMT 03 ATEX E 049
|
100
|
|
|
|
| ||
![]()
Locking screw synthetic, Ex e II, M40
Art:
8841.40
Copied
|
M40
|
|
IP 68
|
1,5
|
|
11,5 mm
|
18 mm
|
46 mm
|
|
8 mm
|
Polyamide
|
NBR
|
|
-20°C ... +90°C
|
CE, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx BVS 07.0021
|
DMT 03 ATEX E 049
|
50
|
|
|
|
| ||
![]()
Locking screw synthetic, Ex e II, M50
Art:
8841.50
Copied
|
M50
|
|
IP 68
|
1,5
|
|
13,5 mm
|
20 mm
|
55 mm
|
|
8 mm
|
Polyamide
|
NBR
|
|
-20°C ... +90°C
|
CE, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx BVS 07.0021
|
DMT 03 ATEX E 049
|
25
|
|
|
|
| ||
![]()
Locking screw synthetic, Ex e II, M63
Art:
8841.63
Copied
|
M63
|
|
IP 68
|
1,5
|
|
14,5 mm
|
21 mm
|
70 mm
|
|
8 mm
|
Polyamide
|
NBR
|
|
-20°C ... +90°C
|
CE, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx BVS 07.0021
|
DMT 03 ATEX E 049
|
10
|
|
|
|
| ||
![]()
Locking screw synthetic, Ex e II, Pg 7
Art:
8841.07
Copied
|
PG 7
|
|
IP 68
|
|
|
8,5 mm
|
13 mm
|
15 mm
|
|
6 mm
|
Polyamide
|
NBR
|
|
-20°C ... +90°C
|
CE, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx BVS 07.0021
|
DMT 03 ATEX E 049
|
100
|
|
|
|
| ||
![]()
Locking screw synthetic, Ex e II, Pg 9
Art:
8841.09
Copied
|
PG 9
|
|
IP 68
|
|
|
8,5 mm
|
13 mm
|
19 mm
|
|
8 mm
|
Polyamide
|
NBR
|
|
-20°C ... +90°C
|
CE, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx BVS 07.0021
|
DMT 03 ATEX E 049
|
100
|
|
|
|
| ||
![]()
Locking screw synthetic, Ex e II, Pg 11
Art:
8841.11
Copied
|
PG 11
|
|
IP 68
|
|
|
9 mm
|
14,5 mm
|
24 mm
|
|
8 mm
|
Polyamide
|
NBR
|
|
-20°C ... +90°C
|
CE, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx BVS 07.0021
|
DMT 03 ATEX E 049
|
100
|
|
|
|
| ||
![]()
Locking screw synthetic, Ex e II, Pg 13
Art:
8841.13
Copied
|
PG 13
|
|
IP 68
|
|
|
9 mm
|
14,5 mm
|
24 mm
|
|
8 mm
|
Polyamide
|
NBR
|
|
-20°C ... +90°C
|
CE, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx BVS 07.0021
|
DMT 03 ATEX E 049
|
100
|
|
|
|
| ||
![]()
Locking screw synthetic, Ex e II, Pg 16
Art:
8841.16
Copied
|
PG 16
|
|
IP 68
|
|
|
10,5 mm
|
16 mm
|
28 mm
|
|
8 mm
|
Polyamide
|
NBR
|
|
-20°C ... +90°C
|
CE, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx BVS 07.0021
|
DMT 03 ATEX E 049
|
100
|
|
|
|
| ||
![]()
Locking screw synthetic, Ex e II, Pg 21
Art:
8841.21
Copied
|
PG 21
|
|
IP 68
|
|
|
11,5 mm
|
17,5 mm
|
36 mm
|
|
8 mm
|
Polyamide
|
NBR
|
|
-20°C ... +90°C
|
CE, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx BVS 07.0021
|
DMT 03 ATEX E 049
|
100
|
|
|
|
| ||
![]()
Locking screw synthetic, Ex e II, Pg 29
Art:
8841.29
Copied
|
PG 29
|
|
IP 68
|
|
|
11,5 mm
|
18 mm
|
46 mm
|
|
8 mm
|
Polyamide
|
NBR
|
|
-20°C ... +90°C
|
CE, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx BVS 07.0021
|
DMT 03 ATEX E 049
|
50
|
|
|
|
| ||
![]()
Locking screw synthetic, Ex e II, Pg 36
Art:
8841.36
Copied
|
PG 36
|
|
IP 68
|
|
|
13,5 mm
|
20 mm
|
55 mm
|
|
8 mm
|
Polyamide
|
NBR
|
|
-20°C ... +90°C
|
CE, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx BVS 07.0021
|
DMT 03 ATEX E 049
|
25
|
|
|
|
| ||
![]()
Locking screw synthetic, Ex e II, Pg 42
Art:
8841.42
Copied
|
PG 42
|
|
IP 68
|
|
|
13,5 mm
|
20 mm
|
60 mm
|
|
8 mm
|
Polyamide
|
NBR
|
|
-20°C ... +90°C
|
CE, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx BVS 07.0021
|
DMT 03 ATEX E 049
|
10
|
|
|
|
| ||
![]()
Locking screw synthetic, Ex e II, Pg 48
Art:
8841.48
Copied
|
PG 48
|
|
IP 68
|
|
|
14,5 mm
|
21 mm
|
70 mm
|
|
8 mm
|
Polyamide
|
NBR
|
|
-20°C ... +90°C
|
CE, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx BVS 07.0021
|
DMT 03 ATEX E 049
|
10
|
|
|
|
| ||
![]()
Pressure balance element, membrane, Ex e II, M20
Art:
EX2450.20.34
Copied
|
M20
|
|
IP 66 / IP 68 / IP 69
|
1,5
|
|
8 mm
|
10 mm
|
22 mm
|
|
|
Nickel-plated brass
|
FPM
|
Polyethersulfone (PES)
|
-60°C ... +100°C
|
CE, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 16.0010
|
SEV 16 ATEX 0143
|
20
|
CH
|
74199949
|
29,2 g
|
| ||
![]()
Pressure balance element, membrane, Ex e II, M12
Art:
EX2450.12.34
Copied
|
M12
|
|
IP 66 / IP 68 / IP 69
|
1,5
|
|
8 mm
|
9,5 mm
|
18 mm
|
|
|
Nickel-plated brass
|
FPM
|
Polyethersulfone (PES)
|
-60°C ... +100°C
|
CE, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 16.0010
|
SEV 16 ATEX 0143
|
25
|
CH
|
74199949
|
16,32 g
|
| ||
![]()
Pressure balance element, membrane, Ex e II, M16
Art:
EX2450.17.34
Copied
|
M16
|
|
IP 66 / IP 68 / IP 69
|
1,5
|
|
8 mm
|
9,5 mm
|
18 mm
|
|
|
Nickel-plated brass
|
FPM
|
Polyethersulfone (PES)
|
-60°C ... +100°C
|
CE, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 16.0010
|
SEV 16 ATEX 0143
|
20
|
CH
|
74199949
|
21 g
|
| ||
![]()
Reduction flange NPB, Ex e II, M10 - M8
Art:
EX3500.10.08
Copied
|
M10
|
M8
|
IP 66 / IP 68
|
1,5
|
1,25 mm
|
5 mm
|
8 mm
|
13 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
7,64 g
|
| ||
![]()
Reduction flange NPB, Ex e II, M12 - M8
Art:
EX3500.12.08
Copied
|
M12
|
M8
|
IP 66 / IP 68
|
1,5
|
1,25 mm
|
5 mm
|
3 mm
|
15 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
5,34 g
|
| ||
![]()
Reduction flange NPB, Ex e II, M12 - M10
Art:
EX3500.12.10
Copied
|
M12
|
M10
|
IP 66 / IP 68
|
1,5
|
1,5 mm
|
5 mm
|
8 mm
|
15 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
10,16 g
|
| ||
![]()
Reduction flange NPB, Ex e II, M16 - M10
Art:
EX3500.17.10
Copied
|
M16
|
M10
|
IP 66 / IP 68
|
1,5
|
1,5 mm
|
5 mm
|
3 mm
|
18 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
9,26 g
|
| ||
![]()
Reduction flange NPB, Ex e II, M16 - M12
Art:
EX3500.17.12
Copied
|
M16
|
M12
|
IP 66 / IP 68
|
1,5
|
1,5 mm
|
5 mm
|
3 mm
|
18 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
7,26 g
|
| ||
![]()
Reduction flange NPB, Ex e II, M20 - M12
Art:
EX3500.20.12
Copied
|
M20
|
M12
|
IP 66 / IP 68
|
1,5
|
1,5 mm
|
6 mm
|
3 mm
|
24 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
18,56 g
|
| ||
![]()
Reduction flange NPB, Ex e II, M20 - M16
Art:
EX3500.20.17
Copied
|
M20
|
M16
|
IP 66 / IP 68
|
1,5
|
1,5 mm
|
6 mm
|
3 mm
|
24 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
11,96 g
|
| ||
![]()
Reduction flange NPB, Ex e II, M25 - M16
Art:
EX3500.25.17
Copied
|
M25
|
M16
|
IP 66 / IP 68
|
1,5
|
1,5 mm
|
7 mm
|
3,5 mm
|
30 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
25
|
CH
|
74199949
|
31,8 g
|
| ||
![]()
Reduction flange NPB, Ex e II, M25 - M20
Art:
EX3500.25.20
Copied
|
M25
|
M20
|
IP 66 / IP 68
|
1,5
|
1,5 mm
|
7 mm
|
3,5 mm
|
30 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
25
|
CH
|
74199949
|
22,82 g
|
| ||
![]()
Reduction flange NPB, Ex e II, M32 - M20
Art:
EX3500.32.20
Copied
|
M32
|
M20
|
IP 66 / IP 68
|
1,5
|
1,5 mm
|
8 mm
|
4 mm
|
36 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
20
|
CH
|
74199949
|
58,85 g
|
| ||
![]()
Reduction flange NPB, Ex e II, M32 - M25
Art:
EX3500.32.25
Copied
|
M32
|
M25
|
IP 66 / IP 68
|
1,5
|
1,5 mm
|
8 mm
|
4 mm
|
36 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
20
|
CH
|
74199949
|
39,95 g
|
| ||
![]()
Reduction flange NPB, Ex e II, M40 - M25
Art:
EX3500.40.25
Copied
|
M40
|
M25
|
IP 66 / IP 68
|
1,5
|
1,5 mm
|
8 mm
|
4,5 mm
|
46 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
10
|
CH
|
74199949
|
99 g
|
| ||
![]()
Reduction flange NPB, Ex e II, M40 - M32
Art:
EX3500.40.32
Copied
|
M40
|
M32
|
IP 66 / IP 68
|
1,5
|
1,5 mm
|
8 mm
|
4,5 mm
|
46 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
10
|
CH
|
74199949
|
67,7 g
|
| ||
![]()
Reduction flange NPB, Ex e II, M50 - M32
Art:
EX3500.50.32
Copied
|
M50
|
M32
|
IP 66 / IP 68
|
1,5
|
1,5 mm
|
9 mm
|
5 mm
|
55 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
10
|
CH
|
74199949
|
159,4 g
|
| ||
![]()
Reduction flange NPB, Ex e II, M50 - M40
Art:
EX3500.50.40
Copied
|
M50
|
M40
|
IP 66 / IP 68
|
1,5
|
1,5 mm
|
9 mm
|
5 mm
|
55 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
10
|
CH
|
74199949
|
105,5 g
|
| ||
![]()
Reduction flange NPB, Ex e II, M63 - M40
Art:
EX3500.63.40
Copied
|
M63
|
M40
|
IP 66 / IP 68
|
1,5
|
1,5 mm
|
10 mm
|
5,5 mm
|
70 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
5
|
CH
|
74199949
|
289,8 g
|
| ||
![]()
Reduction flange NPB, Ex e II, M63 - M50
Art:
EX3500.63.50
Copied
|
M63
|
M50
|
IP 66 / IP 68
|
1,5
|
1,5 mm
|
10 mm
|
5,5 mm
|
70 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
5
|
CH
|
74199949
|
197,6 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 7 - M8
Art:
EX3500.07.08
Copied
|
PG 7
|
M8
|
IP 66 / IP 68
|
|
1,25 mm
|
6 mm
|
3 mm
|
15 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
7,06 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 7 - M10
Art:
EX3500.07.10
Copied
|
PG 7
|
M10
|
IP 66 / IP 68
|
|
1,5 mm
|
6 mm
|
7 mm
|
15 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
10,16 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 9 - M8
Art:
EX3500.09.08
Copied
|
PG 9
|
M8
|
IP 66 / IP 68
|
|
1,25 mm
|
6 mm
|
3 mm
|
18 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
11,46 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 9 - M10
Art:
EX3500.09.10
Copied
|
PG 9
|
M10
|
IP 66 / IP 68
|
|
1,5 mm
|
6 mm
|
3 mm
|
18 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
9,66 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 9 - M12
Art:
EX3500.09.12
Copied
|
PG 9
|
M12
|
IP 66 / IP 68
|
|
1,5 mm
|
6 mm
|
8 mm
|
18 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
15,78 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 11 - M8
Art:
EX3500.11.08
Copied
|
PG 11
|
M8
|
IP 66 / IP 68
|
|
1,25 mm
|
6 mm
|
3 mm
|
21 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
17,5 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 11 - M10
Art:
EX3500.11.10
Copied
|
PG 11
|
M10
|
IP 66 / IP 68
|
|
1,5 mm
|
6 mm
|
3 mm
|
21 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
16,1 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 11 - M12
Art:
EX3500.11.12
Copied
|
PG 11
|
M12
|
IP 66 / IP 68
|
|
1,5 mm
|
6 mm
|
3 mm
|
21 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
13,37 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 11 - M16
Art:
EX3500.11.17
Copied
|
PG 11
|
M16
|
IP 66 / IP 68
|
|
1,5 mm
|
6 mm
|
8 mm
|
21 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
16,56 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 13 - M12
Art:
EX3500.13.12
Copied
|
PG 13
|
M12
|
IP 66 / IP 68
|
|
1,5 mm
|
6 mm
|
3 mm
|
24 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
19,66 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 13 - M16
Art:
EX3500.13.17
Copied
|
PG 13
|
M16
|
IP 66 / IP 68
|
|
1,5 mm
|
6 mm
|
3 mm
|
24 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
13,26 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 16 - M12
Art:
EX3500.16.12
Copied
|
PG 16
|
M12
|
IP 66 / IP 68
|
|
1,5 mm
|
6 mm
|
3 mm
|
24 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
25
|
CH
|
74199949
|
22,62 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 16 - M16
Art:
EX3500.16.17
Copied
|
PG 16
|
M16
|
IP 66 / IP 68
|
|
1,5 mm
|
6 mm
|
3 mm
|
24 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
25
|
CH
|
74199949
|
16,52 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 16 - M20
Art:
EX3500.16.20
Copied
|
PG 16
|
M20
|
IP 66 / IP 68
|
|
1,5 mm
|
6 mm
|
10,5 mm
|
24 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
25
|
CH
|
74199949
|
25,42 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 21 - M16
Art:
EX3500.21.17
Copied
|
PG 21
|
M16
|
IP 66 / IP 68
|
|
1,5 mm
|
7,5 mm
|
3,5 mm
|
30 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
25
|
CH
|
74199949
|
41,52 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 21 - M20
Art:
EX3500.21.20
Copied
|
PG 21
|
M20
|
IP 66 / IP 68
|
|
1,5 mm
|
7,5 mm
|
3,5 mm
|
30 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
25
|
CH
|
74199949
|
31,12 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 21 - M25
Art:
EX3500.21.25
Copied
|
PG 21
|
M25
|
IP 66 / IP 68
|
|
1,5 mm
|
7,5 mm
|
10,5 mm
|
30 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
25
|
CH
|
74199949
|
39,28 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 29 - M25
Art:
EX3500.29.25
Copied
|
PG 29
|
M25
|
IP 66 / IP 68
|
|
1,5 mm
|
8 mm
|
4 mm
|
38 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
20
|
CH
|
74199949
|
60,65 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 29 - M32
Art:
EX3500.29.32
Copied
|
PG 29
|
M32
|
IP 66 / IP 68
|
|
1,5 mm
|
8 mm
|
13 mm
|
38 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
20
|
CH
|
74199949
|
67,6 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 36 - M32
Art:
EX3500.36.32
Copied
|
PG 36
|
M32
|
IP 66 / IP 68
|
|
1,5 mm
|
8 mm
|
4,5 mm
|
50 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
10
|
CH
|
74199949
|
112,1 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 36 - M40
Art:
EX3500.36.40
Copied
|
PG 36
|
M40
|
IP 66 / IP 68
|
|
1,5 mm
|
8 mm
|
4,5 mm
|
50 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
10
|
CH
|
74199949
|
62,4 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 42 - M32
Art:
EX3500.42.32
Copied
|
PG 42
|
M32
|
IP 66 / IP 68
|
|
1,5 mm
|
10 mm
|
5 mm
|
55 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
10
|
CH
|
74199949
|
194,9 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 42 - M40
Art:
EX3500.42.40
Copied
|
PG 42
|
M40
|
IP 66 / IP 68
|
|
1,5 mm
|
10 mm
|
5 mm
|
55 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
10
|
CH
|
74199949
|
138,1 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 42 - M50
Art:
EX3500.42.50
Copied
|
PG 42
|
M50
|
IP 66 / IP 68
|
|
1,5 mm
|
10 mm
|
15 mm
|
55 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
10
|
CH
|
74199949
|
134,9 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 48 - M40
Art:
EX3500.48.40
Copied
|
PG 48
|
M40
|
IP 66 / IP 68
|
|
1,5 mm
|
11 mm
|
5,5 mm
|
65 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
5
|
CH
|
74199949
|
247,4 g
|
| ||
![]()
Reduction flange NPB, Ex e II, Pg 48 - M50
Art:
EX3500.48.50
Copied
|
M8
|
M10
|
IP 66 / IP 68
|
1,25
|
1,5 mm
|
5 mm
|
9 mm
|
13 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
7,96 g
|
| ||
![]()
Extension NPB, Ex e II, M8 - M10
Art:
EX3600.08.10
Copied
|
M8
|
M10
|
IP 66 / IP 68
|
1,25
|
1,5 mm
|
5 mm
|
9 mm
|
13 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
7,96 g
|
| ||
![]()
Extension NPB, Ex e II, M10 - M12
Art:
EX3600.10.12
Copied
|
M10
|
M12
|
IP 66 / IP 68
|
1,5
|
1,5 mm
|
5 mm
|
9 mm
|
15 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
9,56 g
|
| ||
![]()
Extension NPB, Ex e II, M12 - M16
Art:
EX3600.12.17
Copied
|
M12
|
M16
|
IP 66 / IP 68
|
1,5
|
1,5 mm
|
5 mm
|
9 mm
|
18 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
10,96 g
|
| ||
![]()
Extension NPB, Ex e II, M16 - M20
Art:
EX3600.17.20
Copied
|
M16
|
M20
|
IP 66 / IP 68
|
1,5
|
1,5 mm
|
5 mm
|
10 mm
|
24 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
22,38 g
|
| ||
![]()
Extension NPB, Ex e II, M20 - M25
Art:
EX3600.20.25
Copied
|
M20
|
M25
|
IP 66 / IP 68
|
1,5
|
1,5 mm
|
6 mm
|
11,5 mm
|
30 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
25
|
CH
|
74199949
|
45,36 g
|
| ||
![]()
Extension NPB, Ex e II, M25 - M32
Art:
EX3600.25.32
Copied
|
M25
|
M32
|
IP 66 / IP 68
|
1,5
|
1,5 mm
|
7 mm
|
14 mm
|
36 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
25
|
CH
|
74199949
|
58,8 g
|
| ||
![]()
Extension NPB, Ex e II, M32 - M40
Art:
EX3600.32.40
Copied
|
M32
|
M40
|
IP 66 / IP 68
|
1,5
|
1,5 mm
|
8 mm
|
14 mm
|
46 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
25
|
CH
|
74199949
|
98,96 g
|
| ||
![]()
Extension NPB, Ex e II, M40 - M50
Art:
EX3600.40.50
Copied
|
M40
|
M50
|
IP 66 / IP 68
|
1,5
|
1,5 mm
|
8 mm
|
16 mm
|
55 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
10
|
CH
|
74199949
|
146,3 g
|
| ||
![]()
Extension NPB, Ex e II, M50 - M63
Art:
EX3600.50.63
Copied
|
M50
|
M63
|
IP 66 / IP 68
|
1,5
|
1,5 mm
|
9 mm
|
17 mm
|
70 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
10
|
CH
|
74199949
|
237,1 g
|
| ||
![]()
Extension NPB, Ex e II, Pg 7 - M12
Art:
EX3600.07.12
Copied
|
PG 7
|
M12
|
IP 66 / IP 68
|
|
1,5 mm
|
6 mm
|
9 mm
|
15 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
9,96 g
|
| ||
![]()
Extension NPB, Ex e II, Pg 7 - M16
Art:
EX3600.07.17
Copied
|
PG 7
|
M16
|
IP 66 / IP 68
|
|
1,5 mm
|
6 mm
|
9 mm
|
18 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
11,96 g
|
| ||
![]()
Extension NPB, Ex e II, Pg 9 - M16
Art:
EX3600.09.17
Copied
|
PG 9
|
M16
|
IP 66 / IP 68
|
|
1,5 mm
|
6 mm
|
9,5 mm
|
18 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
11,56 g
|
| ||
![]()
Extension NPB, Ex e II, Pg 9 - M20
Art:
EX3600.09.20
Copied
|
PG 9
|
M20
|
IP 66 / IP 68
|
|
1,5 mm
|
6 mm
|
10,5 mm
|
24 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
25,18 g
|
| ||
![]()
Extension NPB, Ex e II, Pg 11- M20
Art:
EX3600.11.20
Copied
|
PG 11
|
M20
|
IP 66 / IP 68
|
|
1,5 mm
|
6 mm
|
10,5 mm
|
24 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
25,68 g
|
| ||
![]()
Extension NPB, Ex e II, Pg 11 - M25
Art:
EX3600.11.25
Copied
|
PG 11
|
M25
|
IP 66 / IP 68
|
|
1,5 mm
|
6 mm
|
11,5 mm
|
30 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
25
|
CH
|
74199949
|
42,04 g
|
| ||
![]()
Extension NPB, Ex e II, Pg 13 - M20
Art:
EX3600.13.20
Copied
|
PG 13
|
M20
|
IP 66 / IP 68
|
|
1,5 mm
|
6 mm
|
10,5 mm
|
24 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
50
|
CH
|
74199949
|
24,58 g
|
| ||
![]()
Extension NPB, Ex e II, Pg 13 - M25
Art:
EX3600.13.25
Copied
|
PG 13
|
M25
|
IP 66 / IP 68
|
|
1,5 mm
|
6 mm
|
11,5 mm
|
30 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
25
|
CH
|
74199949
|
40,12 g
|
| ||
![]()
Extension NPB, Ex e II, Pg 16 - M25
Art:
EX3600.16.25
Copied
|
PG 16
|
M25
|
IP 66 / IP 68
|
|
1,5 mm
|
6 mm
|
11,5 mm
|
30 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
25
|
CH
|
74199949
|
41,56 g
|
| ||
![]()
Extension NPB, Ex e II, Pg 16 - M32
Art:
EX3600.16.32
Copied
|
PG 16
|
M32
|
IP 66 / IP 68
|
|
1,5 mm
|
6 mm
|
13,5 mm
|
36 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
25
|
CH
|
74199949
|
57,96 g
|
| ||
![]()
Extension NPB, Ex e II, Pg 21 - M32
Art:
EX3600.21.32
Copied
|
PG 21
|
M32
|
IP 66 / IP 68
|
|
1,5 mm
|
7,5 mm
|
14 mm
|
36 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
25
|
CH
|
74199949
|
60,94 g
|
| ||
![]()
Extension NPB, Ex e II, Pg 21 - M40
Art:
EX3600.21.40
Copied
|
PG 21
|
M40
|
IP 66 / IP 68
|
|
1,5 mm
|
7,5 mm
|
14 mm
|
46 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
20
|
CH
|
74199949
|
100,32 g
|
| ||
![]()
Extension NPB, Ex e II, Pg 29 - M40
Art:
EX3600.29.40
Copied
|
PG 29
|
M40
|
IP 66 / IP 68
|
|
1,5 mm
|
8 mm
|
14 mm
|
46 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
20
|
CH
|
74199949
|
100,9 g
|
| ||
![]()
Extension NPB, Ex e II, Pg 29 - M50
Art:
EX3600.29.50
Copied
|
PG 29
|
M50
|
IP 66 / IP 68
|
|
1,5 mm
|
8 mm
|
16 mm
|
55 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
10
|
CH
|
74199949
|
152,6 g
|
| ||
![]()
Extension NPB, Ex e II, Pg 36 - M50
Art:
EX3600.36.50
Copied
|
PG 36
|
M50
|
IP 66 / IP 68
|
|
1,5 mm
|
8 mm
|
15 mm
|
55 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
10
|
CH
|
74199949
|
133 g
|
| ||
![]()
Extension NPB, Ex e II, Pg 36 - M63
Art:
EX3600.36.63
Copied
|
PG 36
|
M63
|
IP 66 / IP 68
|
|
1,5 mm
|
8 mm
|
17 mm
|
70 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
10
|
CH
|
74199949
|
243,7 g
|
| ||
![]()
Extension NPB, Ex e II, Pg 42- M63
Art:
EX3600.42.63
Copied
|
PG 42
|
M63
|
IP 66 / IP 68
|
|
1,5 mm
|
10 mm
|
17 mm
|
70 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
10
|
CH
|
74199949
|
244,1 g
|
| ||
![]()
Extension NPB, Ex e II, Pg 48- M63
Art:
EX3600.48.63
Copied
|
PG 48
|
M63
|
IP 66 / IP 68
|
|
1,5 mm
|
11 mm
|
17 mm
|
70 mm
|
|
|
Nickel-plated brass
|
FPM
|
|
-60°C ... +100°C
|
CE, DNV, EX, IECEx
|
IEC EN 60079-0 / IEC EN 60079-7 / IEC EN 60079-31
|
II 2G Ex eb IIC Gb
|
II 2D Ex tb IIIC Db
|
IECEx SEV 15.0018
|
SEV 15 ATEX 0151
|
10
|
CH
|
74199949
|
251,8 g
|
|
Select a variant in the list