STEGO
ZR011 is two thermostats in the same casing. One with a breaking contact for regulation of the heater and one with a closing contact for, for example, regulation of the filter fan or activation of overheating protection.
General data |
|
---|---|
Control range temperature from | 0 °C |
Control range temperature to | 60 °C |
Tolerance switch off | ±4K |
Tolerance for switch on | ±4K |
Hysteresis temperature | 7K |
Mounting | DIN-rail 35mm, quick mount |
Rated operating conditions |
|
Voltage max | 250 V ac |
Inrush max | 16 A |
Breaking capacity | 250 VAC: 10 (2) A. 120 VAC: 15 (2) A. DC: 30W @ 24-72 VDC |
Contact resistance | <10 mΩ |
Electrical lifetime | > 100 000 operations |
Connection type | 4-pole terminal, rigid: 2,5 mm² (AWG 14). |
Humidity | <90 % RH (non-condensing) |
Operational temperature | -45°C ... +80°C |
Storage temperature | -45°C ... +80°C |
Life span | > 100 000 operations |
*Invisible Heading* |
|
---|---|
Operating humidity | < 90% RH |
Humidity storage | <90% RH |
Dimensions |
|
Height | 67 mm |
Width | 50 mm |
Depth | 46 mm |
Weight | 0,09 kg |
Material plastic housing | Plastic |
Material of body | Plastic |
Tightening torque max | 0,5 Nm |
Safety & approvals |
|
Plastic cover | Light grey, UL94 V-0 |
IP class | IP20 |
Approvals | CE, CSA, cULus, EAC, EMC, RoHS, UL E164102, VDE |
Country of origin | Germany |
Flammability class | UL94-V0 |
ZR011 is two thermostats in the same casing. One with a breaking contact for regulation of the heater and one with a closing contact for, for example, regulation of the filter fan or activation of overheating protection.
The smallest logic controller by Crouzet is now 20% off for a limited time only! A powerhouse packed into just 17.5mm! Efficiency, adaptability, and seamless integration with free software.
Do you require signalling devices and beacons in your production process? Download our latest whitepaper!
Here, our customer requires control boxes for electricity metering systems. We leveraged our expertise to deliver easy-to-install, ready-to-use assemblies. We look forward to creating more of these bespoke control boxes for our customer.
This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Control range temperature from | Control range temperature to | Mounting | Colour | Price | ||
---|---|---|---|---|---|---|---|
![]()
ZR 011 Dual thermostat, 0…60°C, normally open and closed
Art:
01172.0-00
Copied
|
0 °C
|
60 °C
|
DIN-rail 35mm, quick mount
|
|
| ||
![]()
ZR 011 Dual thermostat, -10°C…+50°C, 20…80°C, normally closed/open
Art:
01175.0-00
Copied
|
-10 °C
|
80 °C
|
DIN-rail mount, EN60715
|
Light grey
|
|
Select a variant in the list