STEGO
KTO 011 is an electro-magnetic thermostat with one NC contact for regulating, for example, heating elements. KTS 011 is an electro-magnetic thermostat with one NO contact for regulating, for example, filter fans or overheating alarms.
General data |
|
---|---|
Control range temperature from | 0 °C |
Control range temperature to | 60 °C |
Tolerance switch off | ±4K |
Tolerance for switch on | ±4K |
Hysteresis temperature | 7K |
Mounting | DIN-rail 35mm, quick mount |
Rated operating conditions |
|
Voltage max | 250 V ac |
Inrush max | 16 A |
Breaking capacity | 250 VAC, 10 (2) A / 120 VAC, 15 (2) A. DC: 30W @ 24 VDC, up to 72 VDC |
Contact resistance | <20 mΩ |
Electrical lifetime | > 100 000 operations |
Connection type | 2-pole 1-strand: 2,5 mm² (AWG 14) or multistrand 1,5 mm² (AWG 16). Torque 0,8 Nm. |
Humidity | <90 % RH (non-condensing) |
*Invisible Heading* |
|
---|---|
Operational temperature | -45°C ... +80°C |
Storage temperature | -45°C ... +80°C |
Life span | > 1000 000 operations |
Dimensions |
|
Height | 60 mm |
Width | 33 mm |
Depth | 43 mm |
Weight | 0,04 kg |
Material plastic housing | Plastic |
Safety & approvals |
|
Plastic cover | Light grey plastic, UL94 V-0 |
IP class | IP20 |
Approvals | CE, EAC, RoHS, VDE |
Country of origin | Germany |
KTO 011 is an electro-magnetic thermostat with one NC contact for regulating, for example, heating elements. KTS 011 is an electro-magnetic thermostat with one NO contact for regulating, for example, filter fans or overheating alarms.
This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.
We are thrilled to announce the launch of IATECH, THe Industrial Automation Technology expo at Leicester Marriott Hotel on 23rd October. The ultimate platform for showcasing our extensive product range and broad business areas, featuring over 50 leading suppliers under one roof!
The specialist vehicle industry can include automotive and EV, heavy vehicles such as agriculture and rail, and marine. This email takes you through some of the various products we offer for specialist vehicle applications.
This blog post delves into the key components, current trends, and best practices in power distribution, illustrating the significant impact these systems have on our daily operations and long-term energy strategies.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Control range temperature from | Control range temperature to | Control range temperature from | Control range temperature to | Mounting | Breaking capacity | Connection type | Humidity | Life span | Approvals | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
KTO 011 Thermostat, 0-60°C, normally closed
Art:
01140.0-00
Copied
|
0 °C
|
60 °C
|
|
|
DIN-rail 35mm, quick mount
|
250 VAC, 10 (2) A / 120 VAC, 15 (2) A. DC: 30W @ 24 VDC, up to 72 VDC
|
2-pole 1-strand: 2,5 mm² (AWG 14) or multistrand 1,5 mm² (AWG 16). Torque 0,8 Nm.
|
<90 % RH (non-condensing)
|
> 1000 000 operations
|
CE, EAC, RoHS, VDE
|
| ||
KTO 011 Thermostat, 0…60°C, normally closed , UL approved
Art:
01146.9-00
Copied
|
0 °C
|
60 °C
|
|
|
DIN-rail 35mm, quick mount
|
250 VAC, 10 (2) A / 120 VAC, 15 (2) A. DC: 30W @ 24 VDC, up to 72 VDC
|
2-pole 1-strand: 2,5 mm² (AWG 14) or multistrand 1,5 mm² (AWG 16). Torque 0,8 Nm.
|
<90 % RH (non-condensing)
|
> 1000 000 operations
|
CE, CSA, cULus, EAC, RoHS, UL E164102, VDE
|
| ||
KTO 011 Thermostat, -10°C…+50°C, normally closed
Art:
01142.0-00
Copied
|
-10 °C
|
50 °C
|
|
|
DIN-rail mount EN60715
|
250 VAC, 10 (2) A / 120 VAC, 15 (2) A. DC: 30W @ 24 VDC, up to 72 VDC
|
2-pole terminal for 2,5 mm² wires
|
Max. 90 % RH (non-condensing)
|
> 100 000 operations
|
CE, cULus, EAC, RoHS, UL E164102, VDE
|
| ||
KTO 011 Thermostat, 20°C…80°C, normally closed
Art:
01159.0-00
Copied
|
20 °C
|
80 °C
|
|
|
DIN-rail 35mm, quick mount
|
|
|
Max. 90 % RH (non-condensing)
|
> 1000 000 operations
|
CE, CSA, cULus, EAC, RoHS, UL E164102, VDE
|
| ||
KTS 011 Thermostat, 0-60°C, normally open
Art:
01141.0-00
Copied
|
0 °C
|
60 °C
|
|
|
DIN-rail 35mm, quick mount
|
250 VAC, 10 (2) A / 120 VAC, 15 (2) A. DC: 30W @ 24 VDC, up to 72 VDC
|
2-pole 1-strand: 2,5 mm² (AWG 14) or multistrand 1,5 mm² (AWG 16). Torque 0,8 Nm.
|
<90 % RH (non-condensing)
|
> 1000 000 operations
|
CE, EAC, RoHS, VDE
|
| ||
KTS 011 Thermostat, 0…60°C, normally open , UL approved
Art:
01147.9-00
Copied
|
0 °C
|
60 °C
|
|
|
DIN-rail 35mm, quick mount
|
250 VAC, 10 (2) A / 120 VAC, 15 (2) A. DC: 30W @ 24 VDC, up to 72 VDC
|
2-pole 1-strand: 2,5 mm² (AWG 14) or multistrand 1,5 mm² (AWG 16). Torque 0,8 Nm.
|
<90 % RH (non-condensing)
|
> 1000 000 operations
|
CE, CSA, cULus, EAC, RoHS, UL E164102, VDE
|
| ||
KTS 011 Thermostat, -10°C…+50°C, normally open
Art:
01143.0-00
Copied
|
-10 °C
|
50 °C
|
|
|
DIN-rail mount EN60715
|
250 VAC, 10 (2) A / 120 VAC, 15 (2) A. DC: 30W @ 24 VDC, up to 72 VDC
|
2-pole terminal for 2,5 mm² wires
|
Max. 90 % RH (non-condensing)
|
> 100 000 operations
|
CE, cULus, EAC, RoHS, UL E164102, VDE
|
| ||
KTS 011 Thermostat, 20°C…80°C, normally open
Art:
01158.0-00
Copied
|
20 °C
|
80 °C
|
|
|
DIN-rail 35mm, quick mount
|
250 VAC, 10 (2) A / 120 VAC, 15 (2) A. DC: 30W @ 24 VDC, up to 72 VDC
|
|
Max. 90 % RH (non-condensing)
|
> 1000 000 operations
|
CE, CSA, cULus, EAC, RoHS, UL E164102, VDE
|
| ||
KTO 011 Thermostat, 32°F…140°F, normally closed
Art:
01140.9-00
Copied
|
|
|
32 °F
|
140 °F
|
DIN-rail 35mm, quick mount
|
|
|
Max. 90 % RH (non-condensing)
|
> 1000 000 operations
|
CE, CSA, cULus, EAC, RoHS, UL E164102, VDE
|
| ||
KTS 011 Thermostat, 32°F…140°F, normally open
Art:
01141.9-00
Copied
|
|
|
32 °F
|
140 °F
|
DIN-rail 35mm, quick mount
|
|
|
Max. 90 % RH (non-condensing)
|
> 1000 000 operations
|
CE, CSA, cULus, EAC, RoHS, UL E164102, VDE
|
| ||
KTO 011 Thermostat, 14°F…122°F, normally closed
Art:
01142.9-00
Copied
|
|
|
14 °F
|
122 °F
|
DIN-rail 35mm, quick mount
|
|
|
Max. 90 % RH (non-condensing)
|
> 1000 000 operations
|
CE, CSA, cULus, EAC, RoHS, UL E164102, VDE
|
| ||
KTS 011 Thermostat, 14°F…122°F, normally open
Art:
01143.9-00
Copied
|
|
|
14 °F
|
122 °F
|
DIN-rail 35mm, quick mount
|
|
|
Max. 90 % RH (non-condensing)
|
> 1000 000 operations
|
CE, CSA, cULus, EAC, RoHS, UL E164102, VDE
|
|
Select a variant in the list