CROUZET AUTOMATION
Millenium 3 is a compact control unit with powerful functions that provides the capability to build both simple and more complex control and monitoring functions. A few examples of fields of application are air conditioning and heating systems, authorisation controls, vending machines, packaging, pump control and advertising signs. Millenium 3 has the most extensive function library on the market and can even be programmed in Ladder. Function block examples: Time functions, counters, connection timers, mathematical blocks or blocks for analogue signals, logic functions, control of motors, pump control and PID regulation. Millenium 3 also includes “SFC blocks”, which are very useful for sequence programming.
General data |
|
---|---|
Number of inputs | 8 |
Number of outputs | 4 |
Supply voltage | 12 V DC |
Expandable | No |
Display | Yes |
Immunity from micro power cuts | 1 ms |
Memory for data | 368 bits / 200 words, stored for 10 years |
Programming method | Functionblocks / SFC or Ladder |
Program memory | Flash EEPROM |
Program size | FBD 180 blocks, Ladder 120 rows normally |
Real time clock | Yes |
Measurement range analog inputs | 0-10 V DC, 0-12 V DC |
Logic 1 voltage threshold (DC input) | 7 V |
*Invisible Heading* |
|
---|---|
Logic 0 voltage threshold (DC input) | 3 V |
Release time | 5 ms |
Output type | Relay |
Switching voltage max | 250 V AC |
Load current min | 10 mA |
Mechanical life expectancy | 10 Million operations |
Other technical data |
|
Width | 71,2 mm |
Depth | 59,5 mm |
Height | 90 mm |
Temperature operational min | -20 °C |
Temperature operational max | 70 °C |
Approvals | CE, CSA, RoHS, UL |
Millenium 3 is a compact control unit with powerful functions that provides the capability to build both simple and more complex control and monitoring functions. A few examples of fields of application are air conditioning and heating systems, authorisation controls, vending machines, packaging, pump control and advertising signs. Millenium 3 has the most extensive function library on the market and can even be programmed in Ladder. Function block examples: Time functions, counters, connection timers, mathematical blocks or blocks for analogue signals, logic functions, control of motors, pump control and PID regulation. Millenium 3 also includes “SFC blocks”, which are very useful for sequence programming.
This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.
We are thrilled to announce the launch of IATECH, THe Industrial Automation Technology expo at Leicester Marriott Hotel on 23rd October. The ultimate platform for showcasing our extensive product range and broad business areas, featuring over 50 leading suppliers under one roof!
The specialist vehicle industry can include automotive and EV, heavy vehicles such as agriculture and rail, and marine. This email takes you through some of the various products we offer for specialist vehicle applications.
This blog post delves into the key components, current trends, and best practices in power distribution, illustrating the significant impact these systems have on our daily operations and long-term energy strategies.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Number of inputs | Number of outputs | Supply voltage | Expandable | Display | Program size | Measurement range analog inputs | Logic 1 voltage threshold (DC input) | Logic 0 voltage threshold (DC input) | Output type | Switching voltage max | Width | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Millenium 3 CD12 8 In 4 Out Relay 12V dc
Art:
88970045
Copied
|
8
|
4
|
12 V DC
|
No
|
Yes
|
FBD 180 blocks, Ladder 120 rows normally
|
0-10 V DC, 0-12 V DC
|
7 V
|
3 V
|
Relay
|
250 V AC
|
71,2 mm
|
| ||
Millenium 3 CB12 8 In 4 Out Relay 24V dc Blind
Art:
88970021
Copied
|
8
|
4
|
24 V DC
|
No
|
No
|
FBD 180 blocks, Ladder 120 rows normally
|
0-10 V DC, 0-24 V DC
|
15 V
|
5 V
|
Relay
|
250 V AC
|
71,2 mm
|
| ||
Millenium 3 CD12 8 In 4 Out Relay 24V dc
Art:
88970041
Copied
|
8
|
4
|
24 V DC
|
No
|
Yes
|
FBD 180 blocks, Ladder 120 rows normally
|
0-10 V DC, 0-24 V DC
|
15 V
|
5 V
|
Relay
|
250 V AC
|
71,2 mm
|
| ||
Millenium 3 CD12 8 In 4 Out Solid State 24V dc
Art:
88970042
Copied
|
8
|
4
|
24 V DC
|
No
|
Yes
|
FBD 180 blocks, Ladder 120 rows normally
|
0-10 V DC, 0-24 V DC
|
15 V
|
5 V
|
Solid State (including 1 PWM)
|
|
71,2 mm
|
| ||
Millenium 3 CD20 12 In 8 Out Relay 12V dc
Art:
88970055
Copied
|
12
|
8
|
12 V DC
|
No
|
Yes
|
FBD 180 blocks, Ladder 120 rows normally
|
0-10 V DC, 0-12 V DC
|
7 V
|
3 V
|
Relay
|
250 V AC
|
124,6 mm
|
| ||
Millenium 3 CB20 12 In 8 Out Relay 24V dc Blind
Art:
88970031
Copied
|
12
|
8
|
24 V DC
|
No
|
No
|
FBD 180 blocks, Ladder 120 rows normally
|
0-10 V DC, 0-24 V DC
|
15 V
|
5 V
|
Relay
|
250 V AC
|
124,6 mm
|
| ||
Millenium 3 CD20 12 In 8 Out Relay 24V dc
Art:
88970051
Copied
|
12
|
8
|
24 V DC
|
No
|
Yes
|
FBD 180 blocks, Ladder 120 rows normally
|
0-10 V DC, 0-24 V DC
|
15 V
|
5 V
|
Relay
|
250 V AC
|
124,6 mm
|
| ||
Millenium 3 CD20 12 In 8 Out Solid State 24V dc
Art:
88970052
Copied
|
12
|
8
|
24 V DC
|
No
|
Yes
|
FBD 180 blocks, Ladder 120 rows normally
|
0-10 V DC, 0-24 V DC
|
15 V
|
5 V
|
Solid State (including 4 PWM)
|
|
124,6 mm
|
| ||
Millenium 3 XD10 6 In 4 Out Relay 24V dc
Art:
88970141
Copied
|
6
|
4
|
24 V DC
|
Yes
|
Yes
|
FBD 350 blocks, Ladder 120 rows normally
|
0-10 V DC, 0-24 V DC
|
15 V
|
5 V
|
Relay
|
250 V AC
|
71,2 mm
|
| ||
Millenium 3 XD10 6 In 4 Out Solid State 24V dc
Art:
88970142
Copied
|
6
|
4
|
24 V DC
|
Yes
|
Yes
|
FBD 350 blocks, Ladder 120 rows normally
|
0-10 V DC, 0-24 V DC
|
15 V
|
5 V
|
Solid State (including 1 PWM)
|
|
71,2 mm
|
| ||
Millenium 3 XD26 16 In 10 Out Relay 12V dc
Art:
88970165
Copied
|
16
|
10
|
12 V DC
|
Yes
|
Yes
|
FBD 350 blocks, Ladder 120 rows normally
|
0-10 V DC, 0-12 V DC
|
7 V
|
3 V
|
Relay
|
250 V AC
|
124,6 mm
|
| ||
Millenium 3 XD26 16 In 10 Out Solid State 24V dc
Art:
88970162
Copied
|
16
|
10
|
24 V DC
|
Yes
|
Yes
|
FBD 350 blocks, Ladder 120 rows normally
|
0-10 V DC, 0-24 V DC
|
15 V
|
5 V
|
Solid State (including 4 PWM)
|
|
124,6 mm
|
| ||
Millenium 3 XD26 16 In 10 Out Relay 24V dc
Art:
88970161
Copied
|
16
|
10
|
24 V DC
|
Yes
|
Yes
|
FBD 350 blocks, Ladder 120 rows normally
|
0-10 V DC, 0-24 V DC
|
15 V
|
5 V
|
Relay
|
250 V AC
|
124,6 mm
|
| ||
Millenium 3 XB26 16 In 10 Out Relay 24V dc Blind
Art:
88970151
Copied
|
16
|
10
|
24 V DC
|
Yes
|
No
|
FBD 350 blocks, Ladder 120 rows normally
|
0-10 V DC, 0-24 V DC
|
15 V
|
5 V
|
Relay
|
250 V AC
|
124,6 mm
|
| ||
Millenium 3 XB26 16 In 10 Out Solid State 24V dc Blind
Art:
88970152
Copied
|
16
|
10
|
24 V DC
|
Yes
|
No
|
FBD 350 blocks, Ladder 120 rows normally
|
0-10 V DC, 0-24 V DC
|
15 V
|
5 V
|
Solid State (including 4 PWM)
|
|
124,6 mm
|
| ||
Millenium 3 XB26 16 In 10 Out Relay 12V dc Blind
Art:
88970155
Copied
|
16
|
10
|
12 V DC
|
Yes
|
No
|
FBD 350 blocks, Ladder 120 rows normally
|
0-10 V DC, 0-12 V DC
|
7 V
|
3 V
|
Relay
|
250 V AC
|
124,6 mm
|
| ||
Millenium 3 XD26 16 In 10 Out Solid State 12V dc
Art:
88970814
Copied
|
16
|
10
|
12 V DC
|
Yes
|
Yes
|
FBD 350 blocks, Ladder 120 rows normally
|
0-10 V DC, 0-12 V DC
|
7 V
|
3 V
|
Solid State (including 4 PWM)
|
|
124,6 mm
|
| ||
Millenium 3 XB10 6 In 4 Out Relay 24V dc Blind
Art:
88970131
Copied
|
6
|
4
|
24 V DC
|
Yes
|
No
|
FBD 350 blocks, Ladder 120 rows normally
|
0-10 V DC, 0-24 V DC
|
15 V
|
5 V
|
Relay
|
250 V AC
|
71,2 mm
|
|
Select a variant in the list