CROUZET CONTROL
Control relay for phase monitoring with regeneration of voltage and asymmetry. Adjustable switch at the front for adjustment of correct voltage in 3-phase networks. Voltage switch's position is not registered until the operating voltage is switched on. If the switch position is changed during operation, all LEDs (LED indications) begin to flash but the unit will continue to function normally with the voltage that was set at the most recent power connection. The LEDs return to normal function when the correct voltage is restored. The relay monitors the correct phase sequence between the three phases or if any phase is lacking (measured U<0.7xUn), 70 % of the returned voltage. The asymmetry setting is made at the front between 5 and 15 % (the rated voltage between the phases Un x degree of asymmetry, %). Deviations in over-/under-voltage are adjustable between -2 and -20 % of the line voltage (window relay function). In the event of incorrect phase sequence or phase interruption, the relay immediately produces an alarm (drops out), and in the event of an asymmetry or voltage fault, the relay drops out after the set time Tt. If the power is switched on with a measured fault, the relay remains deactivated. Fault indication is accomplished with LEDs, which also differentiates between the various fault causes. If a fault remains after the time delay, a non-flashing LED indicates an asymmetry fault and a flashing LED indicates over-/under-voltage. The LED indication that shows this is labelled with Def. on the front of the relay. Green LED (Un) indicates supply voltage OK. Yellow LED (R) indicates active relay output.
Approvals | CSA, GL, RoHS, UL |
---|---|
Breaking capacity | 5A, 250V AC/DC |
Function | Phase Sequence, Phase Failure, Asymmetry, Under/Overvoltage |
IP class connection | IP20 |
IP class housing | IP30 |
Mounting | 35 mm DIN-Rail |
Output | Relay |
Selection of rated voltage | 220, 380, 400, 415, 440, 480 V |
Storage temperature max | 70 °C |
Storage temperature min | -40 °C |
---|---|
Supply voltage | 3 x 220-480V AC |
Temperature operational max | 50 °C |
Temperature operational min | -20 °C |
Time delay alarm | 0,2 s |
Time delay startup | 0,5 s |
Time delay when exceeding the limit value | 0,1-10s |
Weight | 130 g |
Phase interruption, phase sequence and asymmetry
1: L1
2: L2
3: L3
4: Limit value for asymmetry
5: Hysteresis
6: Relay
7: Delay upon exceeding limit value Tt
Over and under voltage
1: Limit value, over-voltage
2: Hysteresis
3: Limit value, under-voltage
4: L1, L2, L3
5: Relay
6: Delay upon exceeding limit value Tt
Control relay for phase monitoring with regeneration of voltage and asymmetry. Adjustable switch at the front for adjustment of correct voltage in 3-phase networks. Voltage switch's position is not registered until the operating voltage is switched on. If the switch position is changed during operation, all LEDs (LED indications) begin to flash but the unit will continue to function normally with the voltage that was set at the most recent power connection. The LEDs return to normal function when the correct voltage is restored. The relay monitors the correct phase sequence between the three phases or if any phase is lacking (measured U<0.7xUn), 70 % of the returned voltage. The asymmetry setting is made at the front between 5 and 15 % (the rated voltage between the phases Un x degree of asymmetry, %). Deviations in over-/under-voltage are adjustable between -2 and -20 % of the line voltage (window relay function). In the event of incorrect phase sequence or phase interruption, the relay immediately produces an alarm (drops out), and in the event of an asymmetry or voltage fault, the relay drops out after the set time Tt. If the power is switched on with a measured fault, the relay remains deactivated. Fault indication is accomplished with LEDs, which also differentiates between the various fault causes. If a fault remains after the time delay, a non-flashing LED indicates an asymmetry fault and a flashing LED indicates over-/under-voltage. The LED indication that shows this is labelled with Def. on the front of the relay. Green LED (Un) indicates supply voltage OK. Yellow LED (R) indicates active relay output.
This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.
We are thrilled to announce the launch of IATECH, THe Industrial Automation Technology expo at Leicester Marriott Hotel on 23rd October. The ultimate platform for showcasing our extensive product range and broad business areas, featuring over 50 leading suppliers under one roof!
The specialist vehicle industry can include automotive and EV, heavy vehicles such as agriculture and rail, and marine. This email takes you through some of the various products we offer for specialist vehicle applications.
This blog post delves into the key components, current trends, and best practices in power distribution, illustrating the significant impact these systems have on our daily operations and long-term energy strategies.