CONTA-CLIP
The SVBA screw-distributor block makes it possible to distribute potential and power in a compact space without any additional accessories. You can use the distributor block to establish an electromechanical connection between a wire with a large cross-section and one or more wires with small cross-sections. They can be used in installation and distribution board construction and also in controller construction for machinery. The SVBA blocks are mounted by snapping them on to TS 35 DIN rails. They can also be attached directly to a mounting plate using the screw flange located on the side of the housing. The individual blocks can be simply clicked together using a plastic connecting clip.
The SVBA blocks are suitable for aluminum and copper cables from 1.5 to 500 mm². They can be easily encoded using the exchangeable colour-coded marking plates for the N, PE, phases (plates are included in delivery). In addition, the built-in adjustable phase tag makes it easy to display which phase is applied to the block.
Â
Â
General Data |
|
---|---|
Rated current copper | 80 A |
Rated current aluminium | 63 A |
Rated voltage V AC | 1000 V AC |
Rated voltage V DC | 1500 V DC |
Mounting | TS 35 and direct mount |
Approvals | UL |
Overvoltage category | III |
Contamination degree | 3 |
Colour | Dark grey |
IP class | IP20 |
Connection Data |
|
Connections | 7 |
Number of inputs A | 1 |
Input A: rated cross-section | 25 mm² |
Input A: diameter | 10,5 mm |
Input A: wire cross-section rigid, min. | 2,5 mm² |
Input A: wire cross-section rigid, max. | 25 mm² |
Input A: wire cross-section stranded, min. | 2,5 mm² |
Input A: wire cross-section stranded, max. | 25 mm² |
Input A: wire cross-section with wire-end ferrules, min. | 2,5 mm² |
Input A: wire cross-section with wire-end ferrules, max. | 25 mm² |
Input A: stripping length | 20 mm |
Input A: screw head | Allen key |
Input A: torque, max. | 3,5 Nm |
Number of outputs A | 6 |
Output A: rated cross-section | 10 mm² |
Output A: diameter | 4,4 mm |
*Invisible Heading* |
|
---|---|
Output A: wire cross-section rigid, min. | 2,5 mm² |
Output A: wire cross-section rigid, max. | 10 mm² |
Output A: wire cross-section stranded, min. | 2,5 mm² |
Output A: wire cross-section stranded, max. | 6 mm² |
Output A: wire cross-section stranded with wire-end ferrules, min. | 2,5 mm² |
Output A: wire cross-section stranded with wire-end ferrules, max. | 6 mm² |
Output A: stripping length | 10 mm |
Output A: screw head | Allen key |
Output A: torque, max. | 2 Nm |
Dimensions |
|
Length | 89,5 mm |
Height | 49 mm |
Height TS 35/7.5 | 52 mm |
Width | 36 mm |
Materials |
|
Insulation material | Polyamide 6.6 |
Flammability class | UL94-V0 |
Operating temperature to | 120 °C |
Operating temperature from | -40 °C |
Approvals |
|
UL test standard | UL 1953 |
SCCR rating | 10 kV |
Rated voltage UL | 1000 V |
Additional Data |
|
Tariff code | 85369010 |
Country of origin | EEC |
Weight | 124 g |
Pack size | 1 |
The SVBA screw-distributor block makes it possible to distribute potential and power in a compact space without any additional accessories. You can use the distributor block to establish an electromechanical connection between a wire with a large cross-section and one or more wires with small cross-sections. They can be used in installation and distribution board construction and also in controller construction for machinery. The SVBA blocks are mounted by snapping them on to TS 35 DIN rails. They can also be attached directly to a mounting plate using the screw flange located on the side of the housing. The individual blocks can be simply clicked together using a plastic connecting clip.
The SVBA blocks are suitable for aluminum and copper cables from 1.5 to 500 mm². They can be easily encoded using the exchangeable colour-coded marking plates for the N, PE, phases (plates are included in delivery). In addition, the built-in adjustable phase tag makes it easy to display which phase is applied to the block.
Â
Â
This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.
We are thrilled to announce the launch of IATECH, THe Industrial Automation Technology expo at Leicester Marriott Hotel on 23rd October. The ultimate platform for showcasing our extensive product range and broad business areas, featuring over 50 leading suppliers under one roof!
The specialist vehicle industry can include automotive and EV, heavy vehicles such as agriculture and rail, and marine. This email takes you through some of the various products we offer for specialist vehicle applications.
This blog post delves into the key components, current trends, and best practices in power distribution, illustrating the significant impact these systems have on our daily operations and long-term energy strategies.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Rated current copper | Rated current aluminium | Mounting | Approvals | Colour | IP class | Short-circuit current resistance ICW over 1s | Connections | Input A: rated cross-section | Input A: diameter | Input A: wire cross-section rigid, min. | Input A: wire cross-section rigid, max. | Input A: wire cross-section stranded, min. | Input A: wire cross-section stranded, max. | Input A: wire cross-section with wire-end ferrules, min. | Input A: wire cross-section with wire-end ferrules, max. | Input A: stripping length | Input A: torque, max. | Number of outputs A | Output A: rated cross-section | Output A: diameter | Output A: wire cross-section rigid, min. | Output A: wire cross-section rigid, max. | Output A: wire cross-section stranded, min. | Output A: wire cross-section stranded, max. | Output A: wire cross-section stranded with wire-end ferrules, min. | Output A: wire cross-section stranded with wire-end ferrules, max. | Output A: stripping length | Output A: torque, max. | Length | Height | Height TS 35/7.5 | Width | UL test standard | SCCR rating | Rated voltage UL | Weight | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SVBA 85A, Distribution block 80A for Cu/Al cables
Art:
27200.0
Copied
|
80 A
|
63 A
|
TS 35 and direct mount
|
UL
|
Dark grey
|
IP20
|
|
7
|
25 mm²
|
10,5 mm
|
2,5 mm²
|
25 mm²
|
2,5 mm²
|
25 mm²
|
2,5 mm²
|
25 mm²
|
20 mm
|
3,5 Nm
|
6
|
10 mm²
|
4,4 mm
|
2,5 mm²
|
10 mm²
|
2,5 mm²
|
6 mm²
|
2,5 mm²
|
6 mm²
|
10 mm
|
2 Nm
|
89,5 mm
|
49 mm
|
52 mm
|
36 mm
|
UL 1953
|
10 kV
|
1000 V
|
124 g
|
| ||
SVBA 115A, Distribution block 125A for Cu/Al cables
Art:
27201.0
Copied
|
125 A
|
100 A
|
TS 35 and direct mount
|
UL
|
Dark grey
|
IP20
|
|
7
|
50 mm²
|
10,5 mm
|
2,5 mm²
|
50 mm²
|
2,5 mm²
|
35 mm²
|
2,5 mm²
|
35 mm²
|
20 mm
|
4 Nm
|
6
|
25 mm²
|
7 mm
|
2,5 mm²
|
25 mm²
|
2,5 mm²
|
16 mm²
|
2,5 mm²
|
16 mm²
|
10 mm
|
2 Nm
|
89,5 mm
|
49 mm
|
52 mm
|
36 mm
|
UL 1953
|
10 kV
|
1000 V
|
124 g
|
| ||
SVBA 175A, Distribution block 175A for Cu/Al cables
Art:
27202.0
Copied
|
175 A
|
135 A
|
TS 35 and direct mount
|
UL
|
Dark grey
|
IP20
|
|
5
|
70 mm²
|
12,5 mm
|
2,5 mm²
|
70 mm²
|
2,5 mm²
|
50 mm²
|
2,5 mm²
|
50 mm²
|
20 mm
|
4 Nm
|
4
|
35 mm²
|
8,5 mm
|
2,5 mm²
|
35 mm²
|
2,5 mm²
|
25 mm²
|
2,5 mm²
|
25 mm²
|
20 mm
|
3,5 Nm
|
99 mm
|
53 mm
|
56 mm
|
36 mm
|
UL 1953
|
10 kV
|
1000 V
|
153 g
|
| ||
SVBA 255A, Distribution block 250A for Cu/Al cables
Art:
27203.0
Copied
|
250 A
|
200 A
|
TS 35 and direct mount
|
UL
|
Dark grey
|
IP20
|
|
7
|
120 mm²
|
16,5 mm
|
35 mm²
|
120 mm²
|
35 mm²
|
95 mm²
|
35 mm²
|
95 mm²
|
30 mm
|
31 Nm
|
6
|
35 mm²
|
8,5 mm
|
2,5 mm²
|
35 mm²
|
2,5 mm²
|
25 mm²
|
2,5 mm²
|
25 mm²
|
20 mm
|
3,5 Nm
|
114 mm
|
60,7 mm
|
63,7 mm
|
54 mm
|
UL 1953
|
10 kV
|
1000 V
|
295 g
|
| ||
SVBA 380A, Distribution block 415A for Cu/Al cables
Art:
27204.0
Copied
|
415 A
|
360 A
|
TS 35 and direct mount
|
UL
|
Dark grey
|
IP20
|
|
7
|
240 mm²
|
22,5 mm
|
70 mm²
|
240 mm²
|
70 mm²
|
185 mm²
|
70 mm²
|
185 mm²
|
30 mm
|
59 Nm
|
6
|
35 mm²
|
8,5 mm
|
2,5 mm²
|
35 mm²
|
2,5 mm²
|
25 mm²
|
2,5 mm²
|
25 mm²
|
20 mm
|
3,5 Nm
|
114 mm
|
65,7 mm
|
68,7 mm
|
54 mm
|
UL 1953
|
10 kV
|
1000 V
|
351 g
|
| ||
SVBA 1100A, Distribution block 1100A for Cu/Al cables
Art:
27206.0
Copied
|
1100 A
|
900 A
|
Direct mount
|
|
Light grey
|
IP10
|
60 kA
|
3
|
500 mm²
|
40 mm
|
95 mm²
|
500 mm²
|
95 mm²
|
500 mm²
|
95 mm²
|
500 mm²
|
68 mm
|
80 Nm
|
2
|
300 mm²
|
26 mm
|
50 mm²
|
300 mm²
|
50 mm²
|
240 mm²
|
50 mm²
|
240 mm²
|
36 mm
|
50 Nm
|
202 mm
|
107 mm
|
|
90 mm
|
|
60 kV
|
|
2034 g
|
|