CONTA-CLIP
The SVB screw-type distributor block makes it possible to distribute potential and power in a compact space without any additional accessories. You can use the distributor block to establish an electromechanical connection between a wire with a large cross-section and one or more wires with small cross-sections. They can be used in installation and distribution board construction and also in controller construction for machinery.
Â
The SVB blocks are mounted by snapping them on to TS 35 DIN rails. They can also be attached directly to a mounting plate using the screw flange located on the side of the housing.
Â
General Data |
|
---|---|
Rated current copper | 80 A |
Rated voltage V AC | 1000 V AC |
Rated voltage V DC | 1500 V DC |
Mounting | TS 35 and direct mount |
Approvals | UL, cUL, EAC |
Overvoltage category | III |
Rated impulse voltage | 2,5 kV |
Contamination degree | 3 |
Colour | Light grey |
Short-circuit current resistance IPK (peak value) | 2,7 kA |
Short-circuit current resistance ICW over 1s | 1,9 kA |
Connection Data |
|
Connections | 7 |
Number of inputs A | 1 |
Input A: rated cross-section | 16 mm² |
Input A: diameter | 7 mm |
Input A: wire cross-section rigid, min. | 2,5 mm² |
Input A: wire cross-section rigid, max. | 16 mm² |
Input A: wire cross-section stranded, min. | 2,5 mm² |
Input A: wire cross-section stranded, max. | 16 mm² |
Input A: wire cross-section with wire-end ferrules, min. | 2,5 mm² |
Input A: wire cross-section with wire-end ferrules, max. | 16 mm² |
Input A: stripping length | 12 mm |
Input A: screw thread | M 5 |
Input A: screw head | Slotted / Phillips |
Input A: torque, min. | 1,5 Nm |
Input A: torque, max. | 3 Nm |
Number of outputs A | 2 |
Output A: rated cross-section | 16 mm² |
Output A: diameter | 7 mm |
Output A: wire cross-section rigid, min. | 2,5 mm² |
Output A: wire cross-section rigid, max. | 16 mm² |
Output A: wire cross-section stranded, min. | 2,5 mm² |
Output A: wire cross-section stranded, max. | 16 mm² |
Output A: wire cross-section stranded with wire-end ferrules, min. | 2,5 mm² |
Output A: wire cross-section stranded with wire-end ferrules, max. | 16 mm² |
Output A: stripping length | 12 mm |
Output A: screw thread | M 5 |
Output A: screw head | Slotted / Phillips |
Output A: torque, min. | 1,5 Nm |
*Invisible Heading* |
|
---|---|
Output A: torque, max. | 3 Nm |
Number of outputs B | 4 |
Output B: rated cross-section | 6 mm² |
Output B: diameter | 4,5 mm |
Output B: wire cross-section rigid, min. | 2,5 mm² |
Output B: wire cross-section rigid, max. | 6 mm² |
Output B: wire cross-section stranded, min. | 2,5 mm² |
Output B: wire cross-section stranded, max. | 6 mm² |
Output B: wire cross-section stranded with wire-end ferrules, min. | 2,5 mm² |
Output B: wire cross-section stranded with wire-end ferrules, max. | 6 mm² |
Output B: stripping length | 12 mm |
Output B: screw threading | M 4 |
Output B: screw head | Slotted / Phillips |
Output B: torque, min. | 0,8 Nm |
Output B: torque, max. | 1,5 Nm |
Dimensions |
|
Length | 66 mm |
Height | 47 mm |
Height TS 35/7.5 | 50 mm |
Width | 27 mm |
Materials |
|
Insulation material | Polyamide 6.6 |
Flammability class | UL94-V0 |
Operating temperature to | 120 °C |
Operating temperature from | -40 °C |
Approvals |
|
UL overvoltage protection - req. Series fuse class J | 80 A |
UL test standard | UL 1059 |
cUL test standard | C22.2 No 158 |
UL SCCR rating | 100 kA |
EAC test standard | TR ZU 004/2011 |
Req. series fuse class J | 80 A |
Rated current cUL | 80 A |
Rated voltage cUL | 600 V |
SCCR rating | 100 kV |
Rated voltage UL | 600 V |
Rated current UL | 80 A |
Additional Data |
|
Tariff code | 85369010 |
Country of origin | FR |
Weight | 61,4 g |
Pack size | 1 |
The SVB screw-type distributor block makes it possible to distribute potential and power in a compact space without any additional accessories. You can use the distributor block to establish an electromechanical connection between a wire with a large cross-section and one or more wires with small cross-sections. They can be used in installation and distribution board construction and also in controller construction for machinery.
Â
The SVB blocks are mounted by snapping them on to TS 35 DIN rails. They can also be attached directly to a mounting plate using the screw flange located on the side of the housing.
Â
We shine a spotlight on surge protection devices (SPDs), a crucial yet often overlooked component in industrial settings. Every surge of electricity, every fluctuation in voltage, poses a potential threat to your machinery and systems.
Renowned for high-quality cable cutting and crimping tools, Klauke serves electrical contractors, cable jointers, and linemen across a spectrum of sectors
At OEM Automatic, we can supply a series of components for your one project. All under one roof. This case study discusses how we supplied several components for our customer's new electro-pneumatic control box.Â
To promote constant and reliable performance, as well as a longer life of parts in the vehicle, it is important to consider the right cable protector.
We have now added switch disconnectors to our range! Switch disconnectors contribute to the overall functionality and safety of electrical systems.
LOCC-Box from Lutze is an intelligent current monitoring device that provides reliable protection of DC circuits in a slimline 8.1mm housing.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Rated current copper | Rated voltage V AC | Rated voltage V DC | Approvals | Colour | Short-circuit current resistance IPK (peak value) | Short-circuit current resistance ICW over 1s | Additional information | Connections | Number of inputs A | Input A: rated cross-section | Input A: diameter | Input A: wire cross-section rigid, min. | Input A: wire cross-section rigid, max. | Input A: wire cross-section stranded, min. | Input A: wire cross-section stranded, max. | Input A: wire cross-section with wire-end ferrules, min. | Input A: wire cross-section with wire-end ferrules, max. | Input A: stripping length | Input A: screw thread | Input A: screw head | Input A: torque, min. | Input A: torque, max. | Number of inputs B | Input B: rated cross-section | Input B: diameter | Input B: wire cross-section rigid, min. | Input B: wire cross-section rigid, max. | Input B: wire cross-section stranded, min. | Input B: wire cross-section stranded, max. | Input B: wire cross-section, stranded with wire-end ferrules, min. | Input B: wire cross-section stranded with wire-end ferrules, max. | Input B: stripping length | Input B: screw thread | Input B: screw head | Input B: torque, min. | Input B: torque, max. | Number of inputs C | Input C: rated cross-section | Input C: diameter | Input C: wire cross-section rigid, min. | Input C: wire cross-section rigid, max. | Input C: wire cross-section stranded, min. | Input C: wire cross-section stranded, max. | Input C: wire cross-section, stranded with wire-end ferrules, min. | Input C: wire cross-section, stranded with wire-end ferrules, max. | Input C: stripping length | Input C: screw threading | Input C: screw head | Input C: torque, min. | Input C: torque, max. | Number of outputs A | Output A: rated cross-section | Output A: diameter | Output A: wire cross-section rigid, min. | Output A: wire cross-section rigid, max. | Output A: wire cross-section stranded, min. | Output A: wire cross-section stranded, max. | Output A: wire cross-section stranded with wire-end ferrules, min. | Output A: wire cross-section stranded with wire-end ferrules, max. | Output A: stripping length | Output A: screw thread | Output A: screw head | Output A: torque, min. | Output A: torque, max. | Number of outputs B | Output B: rated cross-section | Output B: diameter | Output B: wire cross-section rigid, min. | Output B: wire cross-section rigid, max. | Output B: wire cross-section stranded, min. | Output B: wire cross-section stranded, max. | Output B: wire cross-section stranded with wire-end ferrules, min. | Output B: wire cross-section stranded with wire-end ferrules, max. | Output B: stripping length | Output B: screw threading | Output B: screw head | Output B: torque, min. | Output B: torque, max. | Number of outputs C | Output C: rated cross-section | Output C: diameter | Output C: wire cross-section rigid, min. | Output C: wire cross-section rigid, max. | Output C: wire cross-section stranded, min. | Output C: wire cross-section stranded, max. | Output C: wire cross-section stranded with wire-end ferrules, min. | Output C: wire cross-section stranded with wire-end ferrules, max. | Output C: stripping length | Output C: screw thread | Output C: screw head | Output C: torque, min. | Output C: torque, max. | Special connections | Length | Height | Height TS 35/7.5 | Width | UL overvoltage protection - req. Series fuse class J | UL test standard | cUL test standard | UL SCCR rating | EAC test standard | Req. series fuse class J | Rated current cUL | Rated voltage cUL | SCCR rating | Rated voltage UL | Rated current UL | Country of origin | Weight | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SVB 80, Distribution block 80A
Art:
1740.0
Copied
|
80 A
|
1000 V AC
|
1500 V DC
|
UL, cUL, EAC
|
Light grey
|
2,7 kA
|
1,9 kA
|
|
7
|
1
|
16 mm²
|
7 mm
|
2,5 mm²
|
16 mm²
|
2,5 mm²
|
16 mm²
|
2,5 mm²
|
16 mm²
|
12 mm
|
M 5
|
Slotted / Phillips
|
1,5 Nm
|
3 Nm
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2
|
16 mm²
|
7 mm
|
2,5 mm²
|
16 mm²
|
2,5 mm²
|
16 mm²
|
2,5 mm²
|
16 mm²
|
12 mm
|
M 5
|
Slotted / Phillips
|
1,5 Nm
|
3 Nm
|
4
|
6 mm²
|
4,5 mm
|
2,5 mm²
|
6 mm²
|
2,5 mm²
|
6 mm²
|
2,5 mm²
|
6 mm²
|
12 mm
|
M 4
|
Slotted / Phillips
|
0,8 Nm
|
1,5 Nm
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
66 mm
|
47 mm
|
50 mm
|
27 mm
|
80 A
|
UL 1059
|
C22.2 No 158
|
100 kA
|
TR ZU 004/2011
|
80 A
|
80 A
|
600 V
|
100 kV
|
600 V
|
80 A
|
FR
|
61,4 g
|
| ||
SVB 80, Blue Distribution block 80A
Art:
1740.5
Copied
|
80 A
|
1000 V AC
|
1000 V DC
|
UL, cUL, EAC
|
Blue
|
2,7 kA
|
1,9 kA
|
lid printed blue
|
7
|
1
|
16 mm²
|
7 mm
|
2,5 mm²
|
16 mm²
|
2,5 mm²
|
16 mm²
|
2,5 mm²
|
16 mm²
|
12 mm
|
M 5
|
Slotted / Phillips
|
1,5 Nm
|
3 Nm
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2
|
16 mm²
|
7 mm
|
2,5 mm²
|
16 mm²
|
2,5 mm²
|
16 mm²
|
2,5 mm²
|
16 mm²
|
12 mm
|
M 5
|
Slotted / Phillips
|
1,5 Nm
|
3 Nm
|
4
|
6 mm²
|
4,5 mm
|
2,5 mm²
|
6 mm²
|
2,5 mm²
|
6 mm²
|
2,5 mm²
|
6 mm²
|
12 mm
|
M 4
|
Slotted / Phillips
|
0,8 Nm
|
1,5 Nm
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
66 mm
|
47 mm
|
50 mm
|
27 mm
|
80 A
|
UL 1059
|
C22.2 No 158
|
100 kA
|
TR ZU 004/2011
|
80 A
|
80 A
|
600 V
|
100 kV
|
600 V
|
80 A
|
FR
|
61,4 g
|
| ||
SVB 125, Distribution block 125A
Art:
1741.0
Copied
|
125 A
|
1000 V AC
|
1500 V DC
|
UL, cUL, EAC
|
Light grey
|
30 kA
|
4,2 kA
|
|
8
|
1
|
35 mm²
|
10 mm
|
10 mm²
|
35 mm²
|
10 mm²
|
35 mm²
|
10 mm²
|
35 mm²
|
16 mm
|
M 8
|
Allen key
|
3,5 Nm
|
5 Nm
|
1
|
16 mm²
|
7 mm
|
2,5 mm²
|
16 mm²
|
2,5 mm²
|
16 mm²
|
2,5 mm²
|
16 mm²
|
15 mm
|
M 6
|
Allen key
|
3,5 Nm
|
5 Nm
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6
|
16 mm²
|
6,5 mm
|
2,5 mm²
|
16 mm²
|
2,5 mm²
|
16 mm²
|
2,5 mm²
|
16 mm²
|
12 mm
|
M 5
|
Slotted / Phillips
|
2 Nm
|
3 Nm
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
75 mm
|
47 mm
|
50 mm
|
27 mm
|
125 A
|
UL 1059
|
C22.2 No 158
|
100 kA
|
TR ZU 004/2011
|
125 A
|
115 A
|
600 V
|
100 kV
|
600 V
|
115 A
|
FR
|
136,6 g
|
| ||
SVB 175, Distribution block 175A
Art:
1742.0
Copied
|
175 A
|
1000 V AC
|
1500 V DC
|
UL, cUL, EAC
|
Light grey
|
30 kA
|
11 kA
|
|
11
|
1
|
70 mm²
|
12 mm
|
16 mm²
|
70 mm²
|
16 mm²
|
70 mm²
|
16 mm²
|
70 mm²
|
16 mm
|
M 10
|
Allen key
|
6 Nm
|
10 Nm
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
10
|
16 mm²
|
6,5 mm
|
2,5 mm²
|
16 mm²
|
2,5 mm²
|
16 mm²
|
2,5 mm²
|
16 mm²
|
12 mm
|
M 6
|
Allen key
|
3 Nm
|
4 Nm
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
71 mm
|
43 mm
|
46 mm
|
45 mm
|
|
UL 1059
|
C22.2 No 158
|
|
TR ZU 004/2011
|
125 A
|
175 A
|
600 V
|
100 kV
|
600 V
|
175 A
|
FR
|
221 g
|
| ||
SVB 250, Distribution block 250A
Art:
1743.0
Copied
|
230 A
|
1000 V AC
|
1500 V DC
|
UL, EAC
|
Light grey
|
51 kA
|
24,5 kA
|
|
12
|
1
|
120 mm²
|
15 mm
|
35 mm²
|
120 mm²
|
35 mm²
|
95 mm²
|
35 mm²
|
95 mm²
|
29 mm
|
M 14
|
Allen key
|
19 Nm
|
21 Nm
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2
|
35 mm²
|
9 mm
|
6 mm²
|
35 mm²
|
6 mm²
|
25 mm²
|
6 mm²
|
25 mm²
|
12 mm
|
M 8
|
Slotted
|
3,5 Nm
|
7 Nm
|
5
|
16 mm²
|
6,5 mm
|
1,5 mm²
|
16 mm²
|
1,5 mm²
|
16 mm²
|
1,5 mm²
|
16 mm²
|
12 mm
|
M 6
|
Slotted
|
2 Nm
|
3 Nm
|
4
|
10 mm²
|
6 mm
|
1,5 mm²
|
10 mm²
|
1,5 mm²
|
10 mm²
|
1,5 mm²
|
10 mm²
|
12 mm
|
M 6
|
Slotted
|
2 Nm
|
3 Nm
|
|
96 mm
|
50 mm
|
53 mm
|
44 mm
|
250 A
|
UL 1059
|
|
100 kA
|
TR ZU 004/2011
|
250 A
|
|
|
100 kV
|
600 V
|
230 A
|
FR
|
435,2 g
|
| ||
SVB 400, Distribution block 400A
Art:
1744.0
Copied
|
400 A
|
1000 V AC
|
1500 V DC
|
UL, EAC
|
Light grey
|
51 kA
|
21 kA
|
|
12
|
1
|
185 mm²
|
19 mm
|
95 mm²
|
185 mm²
|
95 mm²
|
150 mm²
|
95 mm²
|
150 mm²
|
29 mm
|
M 16
|
Allen key
|
25 Nm
|
27 Nm
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2
|
35 mm²
|
9 mm
|
6 mm²
|
35 mm²
|
6 mm²
|
25 mm²
|
6 mm²
|
25 mm²
|
12 mm
|
M 8
|
Slotted
|
3,5 Nm
|
7 Nm
|
5
|
16 mm²
|
6,5 mm
|
1,5 mm²
|
16 mm²
|
1,5 mm²
|
16 mm²
|
1,5 mm²
|
16 mm²
|
12 mm
|
M 6
|
Slotted
|
2 Nm
|
3 Nm
|
4
|
10 mm²
|
6 mm
|
1,5 mm²
|
10 mm²
|
1,5 mm²
|
10 mm²
|
1,5 mm²
|
10 mm²
|
12 mm
|
M 6
|
Slotted
|
2 Nm
|
3 Nm
|
|
96 mm
|
50 mm
|
53 mm
|
44 mm
|
350 A
|
UL 1059
|
|
100 kA
|
TR ZU 004/2011
|
350 A
|
|
|
100 kV
|
600 V
|
310 A
|
FR
|
405 g
|
| ||
SVB 175/3, 3-Phase distribution block 250A
Art:
1745.0
Copied
|
160 A
|
1000 V AC
|
1500 V DC
|
UL, cUL, EAC
|
Light grey
|
30 kA
|
11 kA
|
|
3 x 7
|
3 x 1
|
70 mm²
|
12 mm
|
16 mm²
|
70 mm²
|
16 mm²
|
50 mm²
|
16 mm²
|
50 mm²
|
16 mm
|
M 10
|
Allen key
|
6 Nm
|
10 Nm
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 x 6
|
16 mm²
|
6,5 mm
|
2,5 mm²
|
16 mm²
|
2,5 mm²
|
10 mm²
|
2,5 mm²
|
10 mm²
|
12 mm
|
M 6
|
Allen key
|
3 Nm
|
4 Nm
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
71 mm
|
43 mm
|
46 mm
|
80 mm
|
|
UL 1059
|
C22.2 No 158
|
|
TR ZU 004/2011
|
175 A
|
175 A
|
600 V
|
100 kV
|
600 V
|
175 A
|
FR
|
389,4 g
|
| ||
SVB 160, Distribution block 160A
Art:
1746.0
Copied
|
175 A
|
1000 V AC
|
1500 V DC
|
UL, cUL, EAC
|
Light grey
|
30 kA
|
11 kA
|
|
7
|
1
|
70 mm²
|
13 mm
|
10 mm²
|
70 mm²
|
10 mm²
|
70 mm²
|
10 mm²
|
70 mm²
|
18 mm
|
M 10
|
Allen key
|
5 Nm
|
6 Nm
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6
|
16 mm²
|
7 mm
|
2,5 mm²
|
16 mm²
|
2,5 mm²
|
16 mm²
|
2,5 mm²
|
16 mm²
|
12 mm
|
M 5
|
Slotted / Phillips
|
1,5 Nm
|
3 Nm
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Busbar 16 x 5mm
|
92 mm
|
50 mm
|
54 mm
|
35 mm
|
|
UL 1059
|
C22.2 No 158
|
|
TR ZU 004/2011
|
175 A
|
160 A
|
600 V
|
100 kV
|
600 V
|
160 A
|
FR
|
243,8 g
|
| ||
SVB 125/4, 3-Phase distribution block 125A
Art:
1747.0
Copied
|
160 A
|
690 V AC
|
690 V DC
|
|
Light grey
|
30 kA
|
11,8 kA
|
|
3 x 8
|
3 x 1
|
35 mm²
|
9 mm
|
6 mm²
|
35 mm²
|
6 mm²
|
25 mm²
|
6 mm²
|
25 mm²
|
18 mm
|
M 5
|
Slotted / Phillips
|
1,5 Nm
|
3 Nm
|
3 x 5
|
6 mm²
|
5 mm
|
1,5 mm²
|
6 mm²
|
1,5 mm²
|
6 mm²
|
1,5 mm²
|
6 mm²
|
12 mm
|
M 4
|
Slotted / Phillips
|
0,8 Nm
|
1,5 Nm
|
3 x 2
|
16 mm²
|
7 mm
|
4 mm²
|
16 mm²
|
4 mm²
|
10 mm²
|
4 mm²
|
10 mm²
|
18 mm
|
M 5
|
Slotted / Phillips
|
1,5 Nm
|
3 Nm
|
1
|
35 mm²
|
9 mm
|
6 mm²
|
35 mm²
|
6 mm²
|
25 mm²
|
6 mm²
|
25 mm²
|
18 mm
|
M 5
|
Slotted / Phillips
|
1,5 Nm
|
3 Nm
|
4
|
6 mm²
|
5 mm
|
1,5 mm²
|
6 mm²
|
1,5 mm²
|
6 mm²
|
1,5 mm²
|
6 mm²
|
12 mm
|
M 4
|
Slotted / Phillips
|
0,8 Nm
|
1,5 Nm
|
6
|
16 mm²
|
7 mm
|
4 mm²
|
16 mm²
|
4 mm²
|
10 mm²
|
4 mm²
|
10 mm²
|
18 mm
|
M 5
|
Slotted / Phillips
|
1,5 Nm
|
3 Nm
|
Neutral conductor busbar
|
74 mm
|
50 mm
|
53 mm
|
98 mm
|
|
|
|
|
|
|
|
|
|
|
|
EEC
|
315,4 g
|
|