The new PTB range includes a self-extinguishing insulating body: PA 6 UL 94-V0 rated. The conduction block is tinned copper and suitable for aluminium and copper cable connections. The clamps are tined steel and AI alloy with the screws being tinned steel. It has an IP rating of IP20 and is compliant with standard EN 60947-7-1.
Â
General Data |
|
---|---|
IP class | IP20 |
Nominal insulation voltage | 600 V |
Short-circuit current resistance IPK (peak value) | 30 kA |
Short-circuit current resistance ICW over 1s | 4,4 kA |
Connection Data |
|
Connections | 10 |
Number of inputs A | 1 |
Input A: wire cross-section stranded, min. | 10 mm² |
Input A: wire cross-section stranded, max. | 35 mm² |
Input A: wire cross-section with wire-end ferrules, min. | 10 mm² |
Input A: wire cross-section with wire-end ferrules, max. | 35 mm² |
Number of inputs B | 1 |
Input B: wire cross-section stranded, min. | 6 mm² |
Input B: wire cross-section stranded, max. | 16 mm² |
*Invisible Heading* |
|
---|---|
Input B: wire cross-section, stranded with wire-end ferrules, min. | 6 mm² |
Input B: wire cross-section stranded with wire-end ferrules, max. | 16 mm² |
Number of outputs A | 8 |
Output A: wire cross-section stranded, min. | 2,5 mm² |
Output A: wire cross-section stranded, max. | 16 mm² |
Output A: wire cross-section stranded with wire-end ferrules, min. | 2,5 mm² |
Output A: wire cross-section stranded with wire-end ferrules, max. | 16 mm² |
Screw type | Galvanized steel screws |
Dimensions |
|
Length (B) | 40 mm |
Height (A) | 75 mm |
Width (C) | 48 mm |
Additional Data |
|
Pack size | 1 |
Teknomegas new Power Terminal Block (PTB) range boasts an openable and removable frontal protection cover. The body structure has high dielectric features and has a milled clamp for input connections by indirect tightening.
Â
It has a highly reliable connection, with direct connections to COFLEX and COFLEX PLUS. There is also a possibility of connections with J-Link and J-Link Plus with the RPC adapter. It has an easy installation on DIN rails or on panels with screws.
Â
The new PTB range includes a self-extinguishing insulating body: PA 6 UL 94-V0 rated. The conduction block is tinned copper and suitable for aluminium and copper cable connections. The clamps are tined steel and AI alloy with the screws being tinned steel. It has an IP rating of IP20 and is compliant with standard EN 60947-7-1.
Â
This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.
We are thrilled to announce the launch of IATECH, THe Industrial Automation Technology expo at Leicester Marriott Hotel on 23rd October. The ultimate platform for showcasing our extensive product range and broad business areas, featuring over 50 leading suppliers under one roof!
The specialist vehicle industry can include automotive and EV, heavy vehicles such as agriculture and rail, and marine. This email takes you through some of the various products we offer for specialist vehicle applications.
This blog post delves into the key components, current trends, and best practices in power distribution, illustrating the significant impact these systems have on our daily operations and long-term energy strategies.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | IP class | Nominal insulation voltage | Short-circuit current resistance IPK (peak value) | Short-circuit current resistance ICW over 1s | Connections | Number of inputs A | Input A: wire cross-section stranded, min. | Input A: wire cross-section stranded, max. | Input A: wire cross-section with wire-end ferrules, min. | Input A: wire cross-section with wire-end ferrules, max. | Number of inputs B | Input B: wire cross-section stranded, min. | Input B: wire cross-section stranded, max. | Input B: wire cross-section, stranded with wire-end ferrules, min. | Input B: wire cross-section stranded with wire-end ferrules, max. | Number of outputs A | Output A: wire cross-section stranded, min. | Output A: wire cross-section stranded, max. | Output A: wire cross-section stranded with wire-end ferrules, min. | Output A: wire cross-section stranded with wire-end ferrules, max. | Screw type | Length (B) | Height (A) | Width (C) | Pack size | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Art:
PTB6015
Copied
|
IP20
|
600 V
|
30 kA
|
4,4 kA
|
10
|
1
|
10 mm²
|
35 mm²
|
10 mm²
|
35 mm²
|
1
|
6 mm²
|
16 mm²
|
6 mm²
|
16 mm²
|
8
|
2,5 mm²
|
16 mm²
|
2,5 mm²
|
16 mm²
|
Galvanized steel screws
|
40 mm
|
75 mm
|
48 mm
|
1
|
| ||
Art:
PTB6020
Copied
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Art:
PTB6030
Copied
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Art:
PTB6025
Copied
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Select a variant in the list