PULS
Puls Dimension C-series stands for cost optimization without compromising quality, reliability or performance.
CP10 is the second generation C-series 1-phase that sets new records by using the latest technology and sophisticated thermal design. With an efficiency of 94.3%, the power losses are very small and thus the width is reduced down to 39 mm. The efficiency is also very high at lower loads which is the normal operating condition. The mean value is on the whole 93.3% at 230 V ac.
Power boost of 20% enables higher current extraction without voltage drops. This is especially useful during start-ups and to bridge the current peaks in the application. The power reserve can be used continuously up to + 45°C and short periods from +45°C to +60°C.
Short-circuit currents. CP10 can provide short circuit current which is 3 times the nominal current for at least 12 ms, which helps secondary fuses and achieve selectivity. For more information see under Sec. fuses.
Hiccup Plus
With Pulse new short circuit technology ensures optimum protection. The unit leaves a very high short circuit that solves secondary fuses and provide sufficient starting current for example dc motors. If the output voltage drops below 6.5 V dc, a continuous current of 25 A is given for 2 seconds, then turn the assembly of the end to make a new restart attempt after about 18 seconds. This is done until the error has been corrected. This feature ensures a high short-circuit / overload current while avoiding a constant high current that can lead to thermal problems with cables and component damage.
More technical advantages. CP10 has active power factor correction (PFC) and actively protect inrush that effectively reduces start currents which are ideal if several units are connected in the same phase or if the supply is current limited through example. AC UPS. The protection is always active, regardless of the temperature. DC-OK output, wide temperature range, a large number of approvals and transient filter which ensures operation in an interference rich electrical environment makes the unit suitable for virtually all installations. CP10.121 also has an input where the signal turns off the unit.
Â
Â
Wiring | |
A: Primary side/control voltage  B: Secondary. Output voltage  C: potentiometer adjustable output voltage 12-15 V dc  D: DC OK LED. Lights when the voltage is 90% of the set value  E: DC-OK relay output. Closes when the output voltage is OK  F: Inputs for remote shutdown of the unit |
Breakers is the most common type of fuse for ac voltage but is also used for dc voltages. Power supply always has a current limitation compared with an electricity network which hampers tripping of a circuit breaker of the magnetic field, especially if the voltage is as low as 12 V dc. Greater consideration must be given to the cable diameter and cable lengths. This even if the power supply is able to deliver high short circuit currents. For long cables and/or thin cable area so the solution is electronic fuses.
Â
Puls CP10.121 have high short-circuit currents which enables tripping within 10 ms of length and cable section is as below specification.
Â
Â
Safe tripping of circuit breakers with different cable lengths/diameter | Short-circuit currents. Figure 3-2 | ||||
 | 0.75 mm2 | 1.0 mm2 | 1.5 mm2 | 2.5 mm2 | |
C-2A | 11 m | 15 m | 22 m | 35 m | |
C-3A | 9 m | 13 m | 18 m | 23 m | |
C-4A | 5 m | 8 m | 12 m | 17 m | |
C-6A | - | 1 m | 2 m | 3 m | |
B-6A | 6 m | 11 m | 15 m | 23 m | |
B-10A | 2 m | 3 m | 3 m | 4 m | |
B-13A | 1 m | 2 m | 3 m | 4 m | |
 | |||||
Hiccup function Fig 3-3 | |||||
Description of Hiccup plus function | |||||
Thanks to the unique Pul Hiccupplus ensures a high short circuit current while avoiding the risk of overheated cables and damage to the connected loads. When a short circuit occurs following.
|
Â
Input data |
|
---|---|
Input voltage ac | 100-240 V |
Input voltage ac min | 85 V AC |
Input voltage ac max | 264 V AC |
Input voltage dc | 110-150 V |
Input voltage dc min | 88 V DC |
Input voltage dc max | 180 V DC |
Inrush current at 120 V ac typical | 4 A |
Inrush current at 230 V ac typical | 4 A |
Input voltage range | Wide-range |
Power factor at 120 V ac, full load. Typical | 0,98 |
Power factor at 230 V ac, full load. Typical | 0,91 |
Number of phases | 1 |
Output data |
|
Output voltage | 12 V DC |
Output voltage min | 12 V DC |
Output voltage max | 15 V DC |
Output current | 10 A |
Power | 120 W |
Efficiency / Lifetime / MTBF |
|
Efficiency at 120 V ac, full load, typical | 93,2 % |
Efficiency at 230 V ac, typical | 92,3 % |
Efficiency at 230 V ac, full load, typical | 94 % |
Lifetime at 120 V ac, full load and +40 ° C | 94000 h |
Lifetime at 230 V ac, full load and +40 ° C | 110000 h |
Dimensions |
|
---|---|
Width | 32 mm |
Height | 124 mm |
Depth | 102 mm |
Weight | 0,44 kg |
Other |
|
Approvals | ATEX, CE, cULus, IECEx, IEC 62368-1:2018 |
Hold time at 120 V ac, typical full load | 35 ms |
Hold time at 230 V ac, typical full load | 35 ms |
IP class | IP20 |
Clamp type | Screw |
Material protection | Aluminium |
Supply frequency | 50-60 ±6 % |
Ripple max | 50 mV pp |
Series | Dimension C |
Power consumption 120 V ac | 1,09 A |
Power consumption 230 V ac | 0,6 A |
Power drop from +60 °C to + 70 °C | 3 W/°C |
Temperature min without derating | -25 °C |
Temperature max without derating | 60 °C |
Type Power Supply | AC-DC |
DC relay output | Yes |
Active Transient | Yes |
Puls Dimension C-series stands for cost optimization without compromising quality, reliability or performance.
CP10 is the second generation C-series 1-phase that sets new records by using the latest technology and sophisticated thermal design. With an efficiency of 94.3%, the power losses are very small and thus the width is reduced down to 39 mm. The efficiency is also very high at lower loads which is the normal operating condition. The mean value is on the whole 93.3% at 230 V ac.
Power boost of 20% enables higher current extraction without voltage drops. This is especially useful during start-ups and to bridge the current peaks in the application. The power reserve can be used continuously up to + 45°C and short periods from +45°C to +60°C.
Short-circuit currents. CP10 can provide short circuit current which is 3 times the nominal current for at least 12 ms, which helps secondary fuses and achieve selectivity. For more information see under Sec. fuses.
Hiccup Plus
With Pulse new short circuit technology ensures optimum protection. The unit leaves a very high short circuit that solves secondary fuses and provide sufficient starting current for example dc motors. If the output voltage drops below 6.5 V dc, a continuous current of 25 A is given for 2 seconds, then turn the assembly of the end to make a new restart attempt after about 18 seconds. This is done until the error has been corrected. This feature ensures a high short-circuit / overload current while avoiding a constant high current that can lead to thermal problems with cables and component damage.
More technical advantages. CP10 has active power factor correction (PFC) and actively protect inrush that effectively reduces start currents which are ideal if several units are connected in the same phase or if the supply is current limited through example. AC UPS. The protection is always active, regardless of the temperature. DC-OK output, wide temperature range, a large number of approvals and transient filter which ensures operation in an interference rich electrical environment makes the unit suitable for virtually all installations. CP10.121 also has an input where the signal turns off the unit.
Â
Â
Wiring | |
A: Primary side/control voltage  B: Secondary. Output voltage  C: potentiometer adjustable output voltage 12-15 V dc  D: DC OK LED. Lights when the voltage is 90% of the set value  E: DC-OK relay output. Closes when the output voltage is OK  F: Inputs for remote shutdown of the unit |
Breakers is the most common type of fuse for ac voltage but is also used for dc voltages. Power supply always has a current limitation compared with an electricity network which hampers tripping of a circuit breaker of the magnetic field, especially if the voltage is as low as 12 V dc. Greater consideration must be given to the cable diameter and cable lengths. This even if the power supply is able to deliver high short circuit currents. For long cables and/or thin cable area so the solution is electronic fuses.
Â
Puls CP10.121 have high short-circuit currents which enables tripping within 10 ms of length and cable section is as below specification.
Â
Â
Safe tripping of circuit breakers with different cable lengths/diameter | Short-circuit currents. Figure 3-2 | ||||
 | 0.75 mm2 | 1.0 mm2 | 1.5 mm2 | 2.5 mm2 | |
C-2A | 11 m | 15 m | 22 m | 35 m | |
C-3A | 9 m | 13 m | 18 m | 23 m | |
C-4A | 5 m | 8 m | 12 m | 17 m | |
C-6A | - | 1 m | 2 m | 3 m | |
B-6A | 6 m | 11 m | 15 m | 23 m | |
B-10A | 2 m | 3 m | 3 m | 4 m | |
B-13A | 1 m | 2 m | 3 m | 4 m | |
 | |||||
Hiccup function Fig 3-3 | |||||
Description of Hiccup plus function | |||||
Thanks to the unique Pul Hiccupplus ensures a high short circuit current while avoiding the risk of overheated cables and damage to the connected loads. When a short circuit occurs following.
|
Â
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.
We are thrilled to announce the launch of IATECH, THe Industrial Automation Technology expo at Leicester Marriott Hotel on 23rd October. The ultimate platform for showcasing our extensive product range and broad business areas, featuring over 50 leading suppliers under one roof!
The specialist vehicle industry can include automotive and EV, heavy vehicles such as agriculture and rail, and marine. This email takes you through some of the various products we offer for specialist vehicle applications.
This blog post delves into the key components, current trends, and best practices in power distribution, illustrating the significant impact these systems have on our daily operations and long-term energy strategies.
We shine a spotlight on surge protection devices (SPDs), a crucial yet often overlooked component in industrial settings. Every surge of electricity, every fluctuation in voltage, poses a potential threat to your machinery and systems.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Input voltage ac min | Input voltage dc | Input voltage dc max | Inrush current at 120 V ac typical | Inrush current at 230 V ac typical | Power factor at 120 V ac, full load. Typical | Power factor at 230 V ac, full load. Typical | Output current | Power | Efficiency at 120 V ac, full load, typical | Efficiency at 230 V ac, typical | Efficiency at 230 V ac, full load, typical | Lifetime at 120 V ac, full load and +40 ° C | Lifetime at 230 V ac, full load and +40 ° C | MTBF (IEC 61709) 230 V ac, max load, 40 ° C | Width | Depth | Weight | Approvals | Hold time at 120 V ac, typical full load | Hold time at 230 V ac, typical full load | Power consumption 120 V ac | Power consumption 230 V ac | Power drop from +60 °C to + 70 °C | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PSU 100-240V ac I/P 12V dc 10A 120W O/P
Art:
CP5.121
Copied
|
85 V AC
|
110-150 V
|
180 V DC
|
4 A
|
4 A
|
0,98
|
0,91
|
10 A
|
120 W
|
93,2 %
|
92,3 %
|
94 %
|
94000 h
|
110000 h
|
|
32 mm
|
102 mm
|
0,44 kg
|
ATEX, CE, cULus, IECEx, IEC 62368-1:2018
|
35 ms
|
35 ms
|
1,09 A
|
0,6 A
|
3 W/°C
|
| ||
PSU 100-240V ac I/P 12V dc 16A 192W O/P
Art:
CP10.121
Copied
|
90 V AC
|
110-150 V
|
180 V DC
|
6 A
|
9 A
|
0,99
|
0,96
|
16 A
|
192 W
|
92,8 %
|
93,3 %
|
94,3 %
|
75000 h
|
97000 h
|
690000 h
|
39 mm
|
117 mm
|
0,6 kg
|
ABS, CB, CE, CSA, EX, GL, IECEx, UL
|
50 ms
|
50 ms
|
1,74 A
|
0,92 A
|
4,8 W/°C
|
| ||
PSU 100-240V ac I/P 12V dc 16A 192W O/P Wide DC input range
Art:
CP10.122
Copied
|
90 V AC
|
110-300 V
|
360 V DC
|
6 A
|
9 A
|
0,99
|
0,96
|
16 A
|
192 W
|
92,8 %
|
93,3 %
|
94,3 %
|
75000 h
|
97000 h
|
690000 h
|
39 mm
|
117 mm
|
0,6 kg
|
CE, cULus
|
50 ms
|
50 ms
|
1,74 A
|
0,92 A
|
4,8 W/°C
|
|
Select a variant in the list