PULS
Puls Dimension C-series stands for cost optimization without compromising quality, reliability or performance. CPS20.121 high efficiency over a wide load range, which results in reduced power consumption and longer life regardless of load current. An average efficiency is 91.6% with a peak value of 92.6%. In addition, power losses very low at idle, only 3 W at 230 V ac.
Short-circuit currents. CPS20 can leave short-circuit currents which is 4 times the nominal current for 15 ms, which helps secondary fuses and achieve selectivity.
Hiccup Plus.
With new pulse short circuit protection you get optimum protection. The unit leaves a very high short circuit that solves fuses and provides sufficient starting current for example DC motors. If the output voltage falls below 6 V dc is 2x the rated power is left for 2 seconds, then close the unit by the end to make a new restart attempts after about 18 seconds. This feature ensures a high short-circuit/overload current while avoiding a constant high current that can lead to heat and component damage.
Technical advantages. CPS20 has active power factor correction (PFC) and actively current inrush protection that effectively reduces start currents which are ideal if several units are connected in the same phase or if the supply is current limited through example. AC UPS. The protection is always active, regardless of the temperature. DC-OK output, wide temperature range, a large number of approvals and transient filter which ensures operation in interference prone electrical environment makes the unit suitable for virtually all installations.
For a good cooling, we recommend a clearance of 40 mm over 20 mm below and 5 mm on the sides. (15 mm on the sides of adjacent product is a heat source, such as another power supply.)
|
Input data |
|
---|---|
Input voltage range | Wide-range |
Input voltage ac | 100-240 V |
Input voltage ac min | 85 V AC |
Input voltage ac max | 264 V AC |
Inrush current at 230 V ac typical | 7 A |
Number of phases | 1 |
Inrush current at 120 V ac typical | 9 A |
Power factor at 120 V ac, full load. Typical | 0,99 |
Power factor at 230 V ac, full load. Typical | 0,95 |
Output data |
|
Output voltage min | 12 V DC |
Output voltage | 12 V DC |
Output voltage max | 15 V DC |
Power | 360 W |
Output current | 30 A |
Efficiency / Lifetime / MTBF |
|
Lifetime at 120 V ac, full load and +40 ° C | 50000 h |
MTBF (IEC 61709) 230 V ac, max load, 40 ° C | 554000 h |
Efficiency at 230 V ac, full load, typical | 92,6 % |
Efficiency at 230 V ac, typical | 91,6 % |
Lifetime at 230 V ac, full load and +40 ° C | 54000 h |
Efficiency at 120 V ac, full load, typical | 91,4 % |
Dimensions |
|
Weight | 1 kg |
*Invisible Heading* |
|
---|---|
Depth | 127 mm |
Width | 65 mm |
Height | 124 mm |
Other |
|
IP class | IP20 |
Power consumption 120 V ac | 3,3 A |
Ripple max | 100 mV pp |
Power drop from +60 °C to + 70 °C | 0,75 W/°C |
Clamp type | Screw |
Temperature min without derating | -25 °C |
Hold time at 120 V ac, typical full load | 35 ms |
Series | Dimension C |
Hold time at 230 V ac, typical full load | 35 ms |
Power consumption 230 V ac | 1,8 A |
Supply frequency | 50-60 ±6 % |
Approvals | ABS, ATEX, CB, CE, CSA US, cRUus, cULus, GL, IECEx |
Temperature max without derating | 60 °C |
Material protection | Aluminium |
Type Power Supply | AC-DC |
Active Transient | Yes |
DC relay output | Yes |
Puls Dimension C-series stands for cost optimization without compromising quality, reliability or performance. CPS20.121 high efficiency over a wide load range, which results in reduced power consumption and longer life regardless of load current. An average efficiency is 91.6% with a peak value of 92.6%. In addition, power losses very low at idle, only 3 W at 230 V ac.
Short-circuit currents. CPS20 can leave short-circuit currents which is 4 times the nominal current for 15 ms, which helps secondary fuses and achieve selectivity.
Hiccup Plus.
With new pulse short circuit protection you get optimum protection. The unit leaves a very high short circuit that solves fuses and provides sufficient starting current for example DC motors. If the output voltage falls below 6 V dc is 2x the rated power is left for 2 seconds, then close the unit by the end to make a new restart attempts after about 18 seconds. This feature ensures a high short-circuit/overload current while avoiding a constant high current that can lead to heat and component damage.
Technical advantages. CPS20 has active power factor correction (PFC) and actively current inrush protection that effectively reduces start currents which are ideal if several units are connected in the same phase or if the supply is current limited through example. AC UPS. The protection is always active, regardless of the temperature. DC-OK output, wide temperature range, a large number of approvals and transient filter which ensures operation in interference prone electrical environment makes the unit suitable for virtually all installations.
For a good cooling, we recommend a clearance of 40 mm over 20 mm below and 5 mm on the sides. (15 mm on the sides of adjacent product is a heat source, such as another power supply.)
|
Engineers and technicians are seeking solutions that streamline assembly whilst maintaining high levels of protection and flexibility. KDS-SR90 angled screw frames and inlays bring a new level of efficiency to cable routing with a unique 90° entry design.
The smallest logic controller by Crouzet is now 20% off for a limited time only! A powerhouse packed into just 17.5mm! Efficiency, adaptability, and seamless integration with free software.
Do you require signalling devices and beacons in your production process? Download our latest whitepaper!
Here, our customer requires control boxes for electricity metering systems. We leveraged our expertise to deliver easy-to-install, ready-to-use assemblies. We look forward to creating more of these bespoke control boxes for our customer.
This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.