PULS

Power supply 1-phase, 24 V dc Dimension C Series, 20A

Puls Dimension C-series stands for cost optimization without compromising quality, reliability or performance. CPS20.241 high efficiency over a wide load range, which results in reduced power consumption and longer life regardless of load current. An average efficiency is 93.3% with a peak of 94%. In addition, power losses very low at idle, only 2.6 W at 230 Vac. Power boost of 20% enables higher current extraction without voltage drops. This is especially useful during start-ups and to bridge the current peaks in the application. The power reserve can be used continuously up to +45°C and short periods from +45 to +60°C.

Short-circuit currents. CPS20 can leave short-circuit currents which is 4 times the nominal current for 15 ms, which helps secondary fuses and achieve selectivity.

Hiccup Plus.
With new pulse short circuit protection you get optimum protection. The unit leaves a very high short circuit that solves fuses and provides sufficient starting current for example DC motors. If the output voltage drops below 13 V dc will be 2x the rated current is left for 2 seconds, then close the unit by the end to make a new restart attempts after about 18 seconds. This feature ensures a high short-circuit / overload current while avoiding a constant high current that can lead to heat and component damage.

Technical advantages. CPS20 has active power factor correction (PFC) and actively ströminrusningsskydd that effectively reduces start currents which are ideal if several units are connected in the same phase or if the supply is current limited through example. AC UPS. The protection is always active, regardless of the temperature. DC-OK output, wide temperature range, a large number of approvals and transient filter which ensures operation in störrik electrical environment makes the unit suitable for virtually all installations.

 

 

Output characteristics

Efficiency

Output characteristics

Efficiency

 

Peak current at short circuit

Stripping secondary Fuses

Peak current at short circuit

Stripping secondary fuses

Type 90 A for 15 ms enables tripping of example MCBs

 

Read more
  • Output current 20 A
  • Up to 94% efficiency
  • 65 mm wide
  • 20% power reserve
  • Hiccup Plus

Selected variant

Available in several variants

Selected variant

Technical data

Input data

Input voltage range Wide-range
Input voltage ac 100-240 V
Input voltage ac min 85 V AC
Input voltage ac max 264 V AC
Inrush current at 230 V ac typical 7 A
Number of phases 1
Inrush current at 120 V ac typical 9 A
Power factor at 120 V ac, full load. Typical 0,99
Power factor at 230 V ac, full load. Typical 0,95

Output data

Output voltage min 24 V DC
Output voltage 24 V DC
Output voltage max 28 V DC
Power 480 W
Output current 20 A

Efficiency / Lifetime / MTBF

Lifetime at 120 V ac, full load and +40 ° C 70000 h
MTBF (IEC 61709) 230 V ac, max load, 40 ° C 537000 h
Efficiency at 230 V ac, full load, typical 94 %
Efficiency at 230 V ac, typical 93,3 %
Lifetime at 230 V ac, full load and +40 ° C 88000 h
Efficiency at 120 V ac, full load, typical 92,7 %

Dimensions

Weight 1 kg

*Invisible Heading*

Depth 127 mm
Width 65 mm
Height 124 mm

Other

IP class IP20
Power consumption 120 V ac 4,36 A
Ripple max 50 mV pp
Power drop from +60 °C to + 70 °C 12 W/°C
Clamp type Screw on
Temperature min without derating -25 °C
Hold time at 120 V ac, typical full load 26 ms
Series Dimension C
Hold time at 230 V ac, typical full load 26 ms
Power consumption 230 V ac 2,33 A
Supply frequency 50-60 ±6 %
Approvals ABS, CB, CE, CSA, EX, GL, IECEx, UL
Temperature max without derating 60 °C
Material protection Aluminium
Type Power Supply AC-DC
Active Transient Yes
DC relay output Yes

Product description

Puls Dimension C-series stands for cost optimization without compromising quality, reliability or performance. CPS20.241 high efficiency over a wide load range, which results in reduced power consumption and longer life regardless of load current. An average efficiency is 93.3% with a peak of 94%. In addition, power losses very low at idle, only 2.6 W at 230 Vac. Power boost of 20% enables higher current extraction without voltage drops. This is especially useful during start-ups and to bridge the current peaks in the application. The power reserve can be used continuously up to +45°C and short periods from +45 to +60°C.

Short-circuit currents. CPS20 can leave short-circuit currents which is 4 times the nominal current for 15 ms, which helps secondary fuses and achieve selectivity.

Hiccup Plus.
With new pulse short circuit protection you get optimum protection. The unit leaves a very high short circuit that solves fuses and provides sufficient starting current for example DC motors. If the output voltage drops below 13 V dc will be 2x the rated current is left for 2 seconds, then close the unit by the end to make a new restart attempts after about 18 seconds. This feature ensures a high short-circuit / overload current while avoiding a constant high current that can lead to heat and component damage.

Technical advantages. CPS20 has active power factor correction (PFC) and actively ströminrusningsskydd that effectively reduces start currents which are ideal if several units are connected in the same phase or if the supply is current limited through example. AC UPS. The protection is always active, regardless of the temperature. DC-OK output, wide temperature range, a large number of approvals and transient filter which ensures operation in störrik electrical environment makes the unit suitable for virtually all installations.

 

 

Output characteristics

Efficiency

Output characteristics

Efficiency

 

Peak current at short circuit

Stripping secondary Fuses

Peak current at short circuit

Stripping secondary fuses

Type 90 A for 15 ms enables tripping of example MCBs

 

Accessories

Related products

Related

contaclip kds sr90
Product news

Every angle covered with 90 degree cable entry system

Engineers and technicians are seeking solutions that streamline assembly whilst maintaining high levels of protection and flexibility. KDS-SR90 angled screw frames and inlays bring a new level of efficiency to cable routing with a unique 90° entry design.

crouzet millenium slim on limited time discount
Product news

The smallest logic controller ever on limited time discount

The smallest logic controller by Crouzet is now 20% off for a limited time only! A powerhouse packed into just 17.5mm! Efficiency, adaptability, and seamless integration with free software.

11 questions to get the right signalling device with Auer Signal & OEM Automatic
Blog

11 questions to get the right signalling device – a whitepaper

Do you require signalling devices and beacons in your production process? Download our latest whitepaper!

bespoke solutions electricity meter control boxes
Case studies

Control Box Assembly for Industrial Electricity Metering - A case study

Here, our customer requires control boxes for electricity metering systems. We leveraged our expertise to deliver easy-to-install, ready-to-use assemblies. We look forward to creating more of these bespoke control boxes for our customer.

DC circuit protection PISA M and circuit breakers
Blog

Safeguard systems with DC circuit protection

This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.

IATECH, the industrial automation technology exhibition OEM automatic
Company news

Recap of IATECH

Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.

Parts Max entrance tripple Input voltage range Input voltage ac Input voltage ac min Inrush current Input voltage dc max Input voltage dc Input voltage ac max Inrush current at 230 V ac typical Number of phases Inrush current at 120 V ac typical Power factor at 120 V ac, full load. Typical Power factor at 230 V ac, full load. Typical Input voltage dc min Lifetime at 120 V ac, full load and +40 ° C Life span MTBF (IEC 61709) 230 V ac, max load, 40 ° C Efficiency MTBF (IEC 61709) Efficiency at 230 V ac, full load, typical Efficiency at 230 V ac, typical Lifetime at 230 V ac, full load and +40 ° C Efficiency at 120 V ac, full load, typical Weight Power consumption 120 V ac Startup delay Ripple max Hold time at 120 V ac, typical full load Hold time at 230 V ac, typical full load Keep time Power consumption 230 V ac Supply frequency Approvals Conformal coated Price
Wide-range
100-240 V
85 V AC
264 V AC
7 A
1
9 A
0,99
0,95
70000 h
537000 h
94 %
93,3 %
88000 h
92,7 %
1 kg
4,36 A
50 mV pp
26 ms
26 ms
2,33 A
50-60 ±6 %
ABS, CB, CE, CSA, EX, GL, IECEx, UL
Wide-range
100-240 V
85 V AC
264 V AC
7 A
1
9 A
0,99
0,95
70000 h
537000 h
94 %
93,3 %
88000 h
92,7 %
1 kg
4,36 A
50 mV pp
26 ms
26 ms
2,33 A
50-60 ±6 %
ABS, CB, CE, CSA, EAC, EN 50155, EX, GL, IECEx, UL
Yes
50 V pp
Typ. 6/4 A @ 110/300 V DC
360 V DC
110-300 V
88 V DC
110 V DC: 81000 h @ 24 V DC, 20 A, 40 °C
93,1 %
110 V DC: 468000 h @ 24 V DC, 20 A, 40 °C
0,94 kg
1100 ms
70 mV pp
Typ. 26/26 ms @ 110/300 V DC
CB, CE, CSA, EX, IECEx, UL

Selected variant

Select a variant in the list

Contact us
If you need any help, you can contact us in one of the following ways:
0116 284 9900
Send e-mail
Use live chat
Do you need help?
Logo

Cookie settings for OEM.CO.UK

Cookies help us improve your experience with us, so in order to be able to handle login information, offer you personalised content and for basic functionality of this website, we use some cookies.

We will never sell on any information about you. 

You can accept all cookies or personalise your cookies preferences, you can also change your cookie preferences at any time by visiting our contact page.

Necessary Cookies

These cookies are necessary for the website to work and can not be turned off in our systems. They are usually used only in response to actions you have taken in connection with a service request, for example when setting personal preferences, logging in or filling out a form.

Analysis and measurement cookies

These cookies allow us to count the number of visits and traffic sources so that we can measure and improve our website performance. They help us know which pages are more or less popular and how visitors navigate around the site. The information that these cookies collect is aggregated and therefore completely anonymous. If you do not allow these cookies, we do not know when you have visited our website.

Marketing cookies

These cookies can be added by our partners. They can use them to create a profile of you, based on your interests, to show you more relevant information. They do not store any personal information - only information about your browser and device. If you do not accept these cookies, you will have a more general and less customized user experience.