PULS
Puls Dimension C-series stands for cost optimization without compromising quality, reliability or performance. CPS20.241 high efficiency over a wide load range, which results in reduced power consumption and longer life regardless of load current. An average efficiency is 93.3% with a peak of 94%. In addition, power losses very low at idle, only 2.6 W at 230 Vac. Power boost of 20% enables higher current extraction without voltage drops. This is especially useful during start-ups and to bridge the current peaks in the application. The power reserve can be used continuously up to +45°C and short periods from +45 to +60°C.
Short-circuit currents. CPS20 can leave short-circuit currents which is 4 times the nominal current for 15 ms, which helps secondary fuses and achieve selectivity.
Hiccup Plus.
With new pulse short circuit protection you get optimum protection. The unit leaves a very high short circuit that solves fuses and provides sufficient starting current for example DC motors. If the output voltage drops below 13 V dc will be 2x the rated current is left for 2 seconds, then close the unit by the end to make a new restart attempts after about 18 seconds. This feature ensures a high short-circuit / overload current while avoiding a constant high current that can lead to heat and component damage.
Technical advantages. CPS20 has active power factor correction (PFC) and actively ströminrusningsskydd that effectively reduces start currents which are ideal if several units are connected in the same phase or if the supply is current limited through example. AC UPS. The protection is always active, regardless of the temperature. DC-OK output, wide temperature range, a large number of approvals and transient filter which ensures operation in störrik electrical environment makes the unit suitable for virtually all installations.
Â
Â
Output characteristics | Efficiency |
 | |
Peak current at short circuit | Stripping secondary Fuses |
Type 90 A for 15 ms enables tripping of example MCBs |
Â
Input data |
|
---|---|
Input voltage range | Wide-range |
Input voltage ac | 100-240 V |
Input voltage ac min | 85 V AC |
Input voltage ac max | 264 V AC |
Inrush current at 230 V ac typical | 7 A |
Number of phases | 1 |
Inrush current at 120 V ac typical | 9 A |
Power factor at 120 V ac, full load. Typical | 0,99 |
Power factor at 230 V ac, full load. Typical | 0,95 |
Output data |
|
Output voltage min | 24 V DC |
Output voltage | 24 V DC |
Output voltage max | 28 V DC |
Power | 480 W |
Output current | 20 A |
Efficiency / Lifetime / MTBF |
|
Lifetime at 120 V ac, full load and +40 ° C | 70000 h |
MTBF (IEC 61709) 230 V ac, max load, 40 ° C | 537000 h |
Efficiency at 230 V ac, full load, typical | 94 % |
Efficiency at 230 V ac, typical | 93,3 % |
Lifetime at 230 V ac, full load and +40 ° C | 88000 h |
Efficiency at 120 V ac, full load, typical | 92,7 % |
Dimensions |
|
Weight | 1 kg |
*Invisible Heading* |
|
---|---|
Depth | 127 mm |
Width | 65 mm |
Height | 124 mm |
Other |
|
IP class | IP20 |
Power consumption 120 V ac | 4,36 A |
Ripple max | 50 mV pp |
Power drop from +60 °C to + 70 °C | 12 W/°C |
Clamp type | Screw on |
Temperature min without derating | -25 °C |
Hold time at 120 V ac, typical full load | 26 ms |
Series | Dimension C |
Hold time at 230 V ac, typical full load | 26 ms |
Power consumption 230 V ac | 2,33 A |
Supply frequency | 50-60 ±6 % |
Approvals | ABS, CB, CE, CSA, EX, GL, IECEx, UL |
Temperature max without derating | 60 °C |
Material protection | Aluminium |
Type Power Supply | AC-DC |
Active Transient | Yes |
DC relay output | Yes |
Puls Dimension C-series stands for cost optimization without compromising quality, reliability or performance. CPS20.241 high efficiency over a wide load range, which results in reduced power consumption and longer life regardless of load current. An average efficiency is 93.3% with a peak of 94%. In addition, power losses very low at idle, only 2.6 W at 230 Vac. Power boost of 20% enables higher current extraction without voltage drops. This is especially useful during start-ups and to bridge the current peaks in the application. The power reserve can be used continuously up to +45°C and short periods from +45 to +60°C.
Short-circuit currents. CPS20 can leave short-circuit currents which is 4 times the nominal current for 15 ms, which helps secondary fuses and achieve selectivity.
Hiccup Plus.
With new pulse short circuit protection you get optimum protection. The unit leaves a very high short circuit that solves fuses and provides sufficient starting current for example DC motors. If the output voltage drops below 13 V dc will be 2x the rated current is left for 2 seconds, then close the unit by the end to make a new restart attempts after about 18 seconds. This feature ensures a high short-circuit / overload current while avoiding a constant high current that can lead to heat and component damage.
Technical advantages. CPS20 has active power factor correction (PFC) and actively ströminrusningsskydd that effectively reduces start currents which are ideal if several units are connected in the same phase or if the supply is current limited through example. AC UPS. The protection is always active, regardless of the temperature. DC-OK output, wide temperature range, a large number of approvals and transient filter which ensures operation in störrik electrical environment makes the unit suitable for virtually all installations.
Â
Â
Output characteristics | Efficiency |
 | |
Peak current at short circuit | Stripping secondary Fuses |
Type 90 A for 15 ms enables tripping of example MCBs |
Â
Engineers and technicians are seeking solutions that streamline assembly whilst maintaining high levels of protection and flexibility. KDS-SR90 angled screw frames and inlays bring a new level of efficiency to cable routing with a unique 90° entry design.
The smallest logic controller by Crouzet is now 20% off for a limited time only! A powerhouse packed into just 17.5mm! Efficiency, adaptability, and seamless integration with free software.
Do you require signalling devices and beacons in your production process? Download our latest whitepaper!
Here, our customer requires control boxes for electricity metering systems. We leveraged our expertise to deliver easy-to-install, ready-to-use assemblies. We look forward to creating more of these bespoke control boxes for our customer.
This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Max entrance tripple | Input voltage range | Input voltage ac | Input voltage ac min | Inrush current | Input voltage dc max | Input voltage dc | Input voltage ac max | Inrush current at 230 V ac typical | Number of phases | Inrush current at 120 V ac typical | Power factor at 120 V ac, full load. Typical | Power factor at 230 V ac, full load. Typical | Input voltage dc min | Lifetime at 120 V ac, full load and +40 ° C | Life span | MTBF (IEC 61709) 230 V ac, max load, 40 ° C | Efficiency | MTBF (IEC 61709) | Efficiency at 230 V ac, full load, typical | Efficiency at 230 V ac, typical | Lifetime at 230 V ac, full load and +40 ° C | Efficiency at 120 V ac, full load, typical | Weight | Power consumption 120 V ac | Startup delay | Ripple max | Hold time at 120 V ac, typical full load | Hold time at 230 V ac, typical full load | Keep time | Power consumption 230 V ac | Supply frequency | Approvals | Conformal coated | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]()
POWER SUPPLY 24VDC 480W 20A
Art:
CPS20.241
Copied
|
|
Wide-range
|
100-240 V
|
85 V AC
|
|
|
|
264 V AC
|
7 A
|
1
|
9 A
|
0,99
|
0,95
|
|
70000 h
|
|
537000 h
|
|
|
94 %
|
93,3 %
|
88000 h
|
92,7 %
|
1 kg
|
4,36 A
|
|
50 mV pp
|
26 ms
|
26 ms
|
|
2,33 A
|
50-60 ±6 %
|
ABS, CB, CE, CSA, EX, GL, IECEx, UL
|
|
| ||
![]()
Power supply 115/230V, 24VDC/20A Coated.
Art:
CPS20.241-C1
Copied
|
|
Wide-range
|
100-240 V
|
85 V AC
|
|
|
|
264 V AC
|
7 A
|
1
|
9 A
|
0,99
|
0,95
|
|
70000 h
|
|
537000 h
|
|
|
94 %
|
93,3 %
|
88000 h
|
92,7 %
|
1 kg
|
4,36 A
|
|
50 mV pp
|
26 ms
|
26 ms
|
|
2,33 A
|
50-60 ±6 %
|
ABS, CB, CE, CSA, EAC, EN 50155, EX, GL, IECEx, UL
|
Yes
|
| ||
![]()
Puls PSU 110-300VDC/24VDC 480W 20A
Art:
CPS20.241-D1
Copied
|
50 V pp
|
|
|
|
Typ. 6/4 A @ 110/300 V DC
|
360 V DC
|
110-300 V
|
|
|
|
|
|
|
88 V DC
|
|
110 V DC: 81000 h @ 24 V DC, 20 A, 40 °C
|
|
93,1 %
|
110 V DC: 468000 h @ 24 V DC, 20 A, 40 °C
|
|
|
|
|
0,94 kg
|
|
1100 ms
|
70 mV pp
|
|
|
Typ. 26/26 ms @ 110/300 V DC
|
|
|
CB, CE, CSA, EX, IECEx, UL
|
|
|
Select a variant in the list