PULS

Power supply 1-phase, 24 V DC Dimension Q series, 3.4 and 5A

The most outstanding features of this Dimension Q-Series DIN-rail power supply are the high efficiency and the small size, which are achieved by a synchronous rectification and further novel design details. The Q-Series is part of the Dimension family, existing alongside the lower featured C-Series.

With short-term peak power capability of 150% and built-in large sized output capacitors, these features help start motors, charge capacitors and absorb reverse energy and often allow a unit of a lower wattage class to be used 

High immunity to transients and power surges as well as low electromagnetic emission makes usage in nearly every environment possible. 

Unique quick-connect spring-clamp terminals allow a safe and fast installation and a large international approval package for a variety of applications makes this unit suitable for nearly every situation.

  • AC 100-240V Wide-range Input
  • Width only 40mm
  • Efficiency up to 92.7%
  • 150% Peak Load Capability
  • Easy Fuse Tripping due to High Overload Current
  • Active Power Factor Correction (PFC)
  • DC Input from 88 to 360Vdc
  • Negligible low Inrush Current Surge
  • Short-term Operation down to 60Vac and up to 300Vac
  • Full Power Between -25°C and +60°C
  • DC-OK Relay Contact
  • Quick-connect Spring-clamp Terminals
  • 3 Year Warranty
Read more
  • Output currents of 3.4 and 5 A
  • Up to 90% efficiency
  • 50% bonus power up to 4 seconds
  • Spring clamp terminals

Selected variant

Available in several variants

Selected variant

Technical data

Input data

Input voltage range Wide-range
Input voltage ac 100-240 V
Input voltage ac min 85 V AC
Input voltage dc max 150 V DC
Input voltage dc 110-150 V
Input voltage ac max 276 V AC
Number of phases 1
Inrush current at 230 V ac typical 10 A
Inrush current at 120 V ac typical 5 A
Power factor at 120 V ac, full load. Typical 0,53
Power factor at 230 V ac, full load. Typical 0,47
Input voltage dc min 88 V DC

Output data

Output voltage min 24 V DC
Output voltage 24 V DC
Output voltage max 28 V DC
Power 80 W
Output current 3,4 A

Efficiency / Lifetime / MTBF

Lifetime at 120 V ac, full load and +40 ° C 62000 h
MTBF (IEC 61709) 230 V ac, max load, 40 ° C 1451000 h
Efficiency at 230 V ac, full load, typical 90 %
Efficiency at 230 V ac, typical 88,3 %
Lifetime at 230 V ac, full load and +40 ° C 79000 h

*Invisible Heading*

Efficiency at 120 V ac, full load, typical 88,7 %

Dimensions

Weight 0,44 kg
Depth 102 mm
Width 32 mm
Height 124 mm

Other

IP class IP20
Power consumption 120 V ac 1,42 A
Ripple max 50 mV pp
Power drop from +60 °C to + 70 °C 2 W/°C
Clamp type Spring-clamp
Temperature min without derating -25 °C
Hold time at 120 V ac, typical full load 41 ms
Series Dimension Q
Hold time at 230 V ac, typical full load 174 ms
Power consumption 230 V ac 0,82 A
Supply frequency 50-60 ±6 %
Approvals ABS, CB, CE, CSA, GL, UL
Temperature max without derating 60 °C
Material protection Aluminium
Type Power Supply AC-DC

Product description

The most outstanding features of this Dimension Q-Series DIN-rail power supply are the high efficiency and the small size, which are achieved by a synchronous rectification and further novel design details. The Q-Series is part of the Dimension family, existing alongside the lower featured C-Series.

With short-term peak power capability of 150% and built-in large sized output capacitors, these features help start motors, charge capacitors and absorb reverse energy and often allow a unit of a lower wattage class to be used 

High immunity to transients and power surges as well as low electromagnetic emission makes usage in nearly every environment possible. 

Unique quick-connect spring-clamp terminals allow a safe and fast installation and a large international approval package for a variety of applications makes this unit suitable for nearly every situation.

  • AC 100-240V Wide-range Input
  • Width only 40mm
  • Efficiency up to 92.7%
  • 150% Peak Load Capability
  • Easy Fuse Tripping due to High Overload Current
  • Active Power Factor Correction (PFC)
  • DC Input from 88 to 360Vdc
  • Negligible low Inrush Current Surge
  • Short-term Operation down to 60Vac and up to 300Vac
  • Full Power Between -25°C and +60°C
  • DC-OK Relay Contact
  • Quick-connect Spring-clamp Terminals
  • 3 Year Warranty

Accessories

Related products

Related

contaclip kds sr90
Product news

Every angle covered with 90 degree cable entry system

Engineers and technicians are seeking solutions that streamline assembly whilst maintaining high levels of protection and flexibility. KDS-SR90 angled screw frames and inlays bring a new level of efficiency to cable routing with a unique 90° entry design.

crouzet millenium slim on limited time discount
Product news

The smallest logic controller ever on limited time discount

The smallest logic controller by Crouzet is now 20% off for a limited time only! A powerhouse packed into just 17.5mm! Efficiency, adaptability, and seamless integration with free software.

11 questions to get the right signalling device with Auer Signal & OEM Automatic
Blog

11 questions to get the right signalling device – a whitepaper

Do you require signalling devices and beacons in your production process? Download our latest whitepaper!

bespoke solutions electricity meter control boxes
Case studies

Control Box Assembly for Industrial Electricity Metering - A case study

Here, our customer requires control boxes for electricity metering systems. We leveraged our expertise to deliver easy-to-install, ready-to-use assemblies. We look forward to creating more of these bespoke control boxes for our customer.

DC circuit protection PISA M and circuit breakers
Blog

Safeguard systems with DC circuit protection

This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.

IATECH, the industrial automation technology exhibition OEM automatic
Company news

Recap of IATECH

Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.

Parts Input voltage dc max Input voltage dc Input voltage ac max Inrush current at 230 V ac typical Inrush current at 120 V ac typical Power factor at 120 V ac, full load. Typical Power factor at 230 V ac, full load. Typical Power Output current Lifetime at 120 V ac, full load and +40 ° C MTBF (IEC 61709) 230 V ac, max load, 40 ° C Efficiency at 230 V ac, full load, typical Efficiency at 230 V ac, typical Lifetime at 230 V ac, full load and +40 ° C Efficiency at 120 V ac, full load, typical Weight Depth Width Power consumption 120 V ac Power drop from +60 °C to + 70 °C Hold time at 120 V ac, typical full load Hold time at 230 V ac, typical full load Power consumption 230 V ac Approvals Active Transient DC relay output Conformal coated Price
150 V DC
110-150 V
276 V AC
10 A
5 A
0,53
0,47
80 W
3,4 A
62000 h
1451000 h
90 %
88,3 %
79000 h
88,7 %
0,44 kg
102 mm
32 mm
1,42 A
2 W/°C
41 ms
174 ms
0,82 A
ABS, CB, CE, CSA, GL, UL
360 V DC
110-300 V
264 V AC
11 A
9 A
0,99
0,91
120 W
5 A
70000 h
831000 h
92,7 %
90,3 %
89000 h
91,6 %
0,62 kg
117 mm
40 mm
1,1 A
3 W/°C
34 ms
65 ms
0,62 A
ABS, CB, CE, CSA, GL, UL
Yes
Yes
360 V DC
110-300 V
264 V AC
11 A
9 A
0,99
0,91
120 W
5 A
70000 h
831000 h
92,7 %
90,3 %
89000 h
91,6 %
0,62 kg
117 mm
40 mm
1,1 A
3 W/°C
34 ms
65 ms
0,62 A
ABS, ATEX, CB, CE, CSA, GL, IECEx, UL
Yes
Yes
Yes

Selected variant

Select a variant in the list

Contact us
If you need any help, you can contact us in one of the following ways:
0116 284 9900
Send e-mail
Use live chat
Do you need help?
Logo

Cookie settings for OEM.CO.UK

Cookies help us improve your experience with us, so in order to be able to handle login information, offer you personalised content and for basic functionality of this website, we use some cookies.

We will never sell on any information about you. 

You can accept all cookies or personalise your cookies preferences, you can also change your cookie preferences at any time by visiting our contact page.

Necessary Cookies

These cookies are necessary for the website to work and can not be turned off in our systems. They are usually used only in response to actions you have taken in connection with a service request, for example when setting personal preferences, logging in or filling out a form.

Analysis and measurement cookies

These cookies allow us to count the number of visits and traffic sources so that we can measure and improve our website performance. They help us know which pages are more or less popular and how visitors navigate around the site. The information that these cookies collect is aggregated and therefore completely anonymous. If you do not allow these cookies, we do not know when you have visited our website.

Marketing cookies

These cookies can be added by our partners. They can use them to create a profile of you, based on your interests, to show you more relevant information. They do not store any personal information - only information about your browser and device. If you do not accept these cookies, you will have a more general and less customized user experience.