PULS

Power supply 1-phase, 36 V dc Dimension C Series

Puls Dimension C-series stands for cost optimization without compromising quality, reliability or performance. CPS20.361 high efficiency over a wide load range, which results in reduced power consumption and longer life regardless of load current. An average efficiency is 93.2% with a peak value of 94.3%. In addition, power losses very low at idle, only 2.8 W at 230 V ac.

Short-circuit currents. CPS20 can leave short-circuit currents which is 4 times the nominal current for 15 ms, which helps secondary fuses and achieve selectivity.

Hiccup Plus.

With new pulse short circuit protection you get optimum protection. The unit leaves a very high short circuit that solves fuses and provides sufficient starting current for example DC motors. If the output voltage drops below 20 V dc will be left 2x rated current for 2 seconds, then close the unit by the end to make a new restart attempts after about 18 seconds. This feature ensures a high short-circuit/overload current while avoiding a constant high current that can lead to heat and component damage.

Technical advantages. CPS20 has active power factor correction (PFC) and active power inrush protection that effectively reduces start currents which are ideal if several units are connected in the same phase or if the supply is current limited through example. AC UPS. The protection is always active, regardless of the temperature. DC-OK output, wide temperature range, a large number of approvals and transient filter which ensures operation in interference prone electrical environment makes the unit suitable for virtually all installations.

 

For good ventilation, we recommend a clearance of 40 mm over 20 mm below and 5 mm on the sides. (15 mm on the sides of adjacent product is a heat source, such as another power supply.)

 

 

Stripping sec. fuses

 

0.75 mm2

1.0 mm2

1.5 mm2

2.5 mm2

C-2A

51 m

69 m

100 m

153 m

C-3A

43 m

57 m

83 m

128 m

C-4A

32 m

44 m

64 m

99 m

C-6A

8 m

13 m

19 m

31 m

C-8A

3 m

5 m

7 m

10 m

C-10A

2 m

4 m

6 m

8 m

C-13A

-

1 m

2 m

5 m

B-6A

29 m

39 m

54 m

79 m

B-10A

8 m

11 m

19 m

24 m

B-13A

7 m

9 m

14 m

23 m

B-16A

1 m

1 m

2 m

4 m

 

 

Read more
  • Output current of 13.3 A
  • Up to 94.2% accuracy
  • Active PFC
  • High short-circuit currents
  • Hiccup Plus

Selected variant

PSU 100-240V ac I/P 36V dc 13.3A 480W O/P

PSU 100-240V ac I/P 36V dc 13.3A 480W O/P

Art:

Selected variant

Technical data

Input data

Input voltage ac 100-240 V
Input voltage ac min 100 V AC
Input voltage ac max 264 V AC
Inrush current at 120 V ac typical 9 A
Inrush current at 230 V ac typical 7 A
Input voltage range Wide-range
Power factor at 120 V ac, full load. Typical 0,99
Power factor at 230 V ac, full load. Typical 0,95
Number of phases 1

Output data

Output voltage 36 V DC
Output voltage min 36 V DC
Output voltage max 42 V DC
Output current 13,3 A
Power 480 W

Efficiency / Lifetime / MTBF

Efficiency at 120 V ac, full load, typical 93 %
Efficiency at 230 V ac, typical 93,2 %
Efficiency at 230 V ac, full load, typical 94,3 %
Lifetime at 120 V ac, full load and +40 ° C 85000 h
Lifetime at 230 V ac, full load and +40 ° C 101000 h
MTBF (IEC 61709) 230 V ac, max load, 40 ° C 537000 h

Dimensions

Width 65 mm

*Invisible Heading*

Height 124 mm
Depth 127 mm
Weight 1 kg

Other

Approvals ABS, ATEX, CB, CE, CSA US, cRUus, cULus, GL, IECEx
Hold time at 120 V ac, typical full load 26 ms
Hold time at 230 V ac, typical full load 26 ms
IP class IP20
Clamp type Screw on
Material protection Aluminium
Supply frequency 50-60 ±6 %
Ripple max 100 mV pp
Series Dimension C
Power consumption 120 V ac 4,36 A
Power consumption 230 V ac 2,33 A
Power drop from +60 °C to + 70 °C 12 W/°C
Temperature min without derating -25 °C
Temperature max without derating 60 °C
Type Power Supply AC-DC
DC relay output Yes
Active Transient Yes

Product description

Puls Dimension C-series stands for cost optimization without compromising quality, reliability or performance. CPS20.361 high efficiency over a wide load range, which results in reduced power consumption and longer life regardless of load current. An average efficiency is 93.2% with a peak value of 94.3%. In addition, power losses very low at idle, only 2.8 W at 230 V ac.

Short-circuit currents. CPS20 can leave short-circuit currents which is 4 times the nominal current for 15 ms, which helps secondary fuses and achieve selectivity.

Hiccup Plus.

With new pulse short circuit protection you get optimum protection. The unit leaves a very high short circuit that solves fuses and provides sufficient starting current for example DC motors. If the output voltage drops below 20 V dc will be left 2x rated current for 2 seconds, then close the unit by the end to make a new restart attempts after about 18 seconds. This feature ensures a high short-circuit/overload current while avoiding a constant high current that can lead to heat and component damage.

Technical advantages. CPS20 has active power factor correction (PFC) and active power inrush protection that effectively reduces start currents which are ideal if several units are connected in the same phase or if the supply is current limited through example. AC UPS. The protection is always active, regardless of the temperature. DC-OK output, wide temperature range, a large number of approvals and transient filter which ensures operation in interference prone electrical environment makes the unit suitable for virtually all installations.

 

For good ventilation, we recommend a clearance of 40 mm over 20 mm below and 5 mm on the sides. (15 mm on the sides of adjacent product is a heat source, such as another power supply.)

 

 

Stripping sec. fuses

 

0.75 mm2

1.0 mm2

1.5 mm2

2.5 mm2

C-2A

51 m

69 m

100 m

153 m

C-3A

43 m

57 m

83 m

128 m

C-4A

32 m

44 m

64 m

99 m

C-6A

8 m

13 m

19 m

31 m

C-8A

3 m

5 m

7 m

10 m

C-10A

2 m

4 m

6 m

8 m

C-13A

-

1 m

2 m

5 m

B-6A

29 m

39 m

54 m

79 m

B-10A

8 m

11 m

19 m

24 m

B-13A

7 m

9 m

14 m

23 m

B-16A

1 m

1 m

2 m

4 m

 

 

Accessories

Related products

Related

DC circuit protection PISA M and circuit breakers
Knowledge

Safeguard systems with DC circuit protection

This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.

IATECH, the industrial automation technology exhibition OEM automatic
Company news

Recap of IATECH

Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.

zoller and frohlich cable preparation machines
Product news Blog

Book your Cable Preparation Machinery Demo at OEM

To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.

IATECH industrial automation components exhibition in at leicester marriott hotel by OEM Automatic
Company news

OEM introduces IATECH - The Industrial Automation Technology Expo

We are thrilled to announce the launch of IATECH, THe Industrial Automation Technology expo at Leicester Marriott Hotel on 23rd October. The ultimate platform for showcasing our extensive product range and broad business areas, featuring over 50 leading suppliers under one roof!

automation components for specialist vehicles
Blog

Automation Components for Specialist Vehicles

The specialist vehicle industry can include automotive and EV, heavy vehicles such as agriculture and rail, and marine.  This email takes you through some of the various products we offer for specialist vehicle applications.

Wohner power distribution
Product news Blog

Modern Power Distribution

This blog post delves into the key components, current trends, and best practices in power distribution, illustrating the significant impact these systems have on our daily operations and long-term energy strategies.

Contact us
If you need any help, you can contact us in one of the following ways:
0116 284 9900
Send e-mail
Use live chat
Do you need help?
Logo

Cookie settings for OEM.CO.UK

Cookies help us improve your experience with us, so in order to be able to handle login information, offer you personalised content and for basic functionality of this website, we use some cookies.

We will never sell on any information about you. 

You can accept all cookies or personalise your cookies preferences, you can also change your cookie preferences at any time by visiting our contact page.

Necessary Cookies

These cookies are necessary for the website to work and can not be turned off in our systems. They are usually used only in response to actions you have taken in connection with a service request, for example when setting personal preferences, logging in or filling out a form.

Analysis and measurement cookies

These cookies allow us to count the number of visits and traffic sources so that we can measure and improve our website performance. They help us know which pages are more or less popular and how visitors navigate around the site. The information that these cookies collect is aggregated and therefore completely anonymous. If you do not allow these cookies, we do not know when you have visited our website.

Marketing cookies

These cookies can be added by our partners. They can use them to create a profile of you, based on your interests, to show you more relevant information. They do not store any personal information - only information about your browser and device. If you do not accept these cookies, you will have a more general and less customized user experience.