PULS
Puls Dimension C-series stands for cost optimization without compromising quality, reliability or performance. CPS20.481 high efficiency over a wide load range, which results in reduced power consumption and longer life regardless of load current. An average efficiency is 92.8% with a peak value of 93.9%. In addition, power losses very low at idle, only 2.4 W at 230 V ac.
Short-circuit currents. CPS20 can leave short-circuit currents which is 4 times the nominal current for 15 ms, which helps secondary fuses and achieve selectivity.
Hiccup Plus.
With new pulse short circuit protection you get optimum protection. The unit leaves a very high short circuit that solves fuses and provides sufficient starting current for example dc motors. If the output voltage drops below 25 V DC will be left 2x rated current for 2 seconds, then close the unit by the end to make a new restart attempts after about 18 seconds. This feature ensures a high short-circuit/overload current while avoiding a constant high current that can lead to heat and component damage.
Technical advantages. CPS20 has active power factor correction (PFC) and active power inrush protection that effectively reduces start currents which are ideal if several units are connected in the same phase or if the supply is current limited through example. AC UPS. The protection is always active, regardless of the temperature. DC-OK output, wide temperature range, a large number of approvals and transient filter which ensures operation in störrik electrical environment makes the unit suitable for virtually all installations.
Â
For approved cooling, we recommend free space of 40 mm above. 20 mm under and 5 mm on the sides. (15 mm if there is another power supply)
Â
   |
Â
Â
Input data |
|
---|---|
Input voltage ac | 100-240 V |
Input voltage ac min | 100 V AC |
Input voltage ac max | 264 V AC |
Inrush current at 120 V ac typical | 9 A |
Inrush current at 230 V ac typical | 7 A |
Input voltage range | Wide-range |
Power factor at 120 V ac, full load. Typical | 0,99 |
Power factor at 230 V ac, full load. Typical | 0,95 |
Number of phases | 1 |
Output data |
|
Output voltage | 48 V DC |
Output voltage min | 48 V DC |
Output voltage max | 56 V DC |
Output current | 10 A |
Power | 480 W |
Efficiency / Lifetime / MTBF |
|
Efficiency at 120 V ac, full load, typical | 92,6 % |
Efficiency at 230 V ac, typical | 92,8 % |
Efficiency at 230 V ac, full load, typical | 93,9 % |
Lifetime at 120 V ac, full load and +40 ° C | 70000 h |
Lifetime at 230 V ac, full load and +40 ° C | 87000 h |
MTBF (IEC 61709) 230 V ac, max load, 40 ° C | 537000 h |
Dimensions |
|
Width | 65 mm |
*Invisible Heading* |
|
---|---|
Height | 124 mm |
Depth | 117 mm |
Weight | 1 kg |
Other |
|
Approvals | ABS, ATEX, CB, CE, CSA US, cRUus, cULus, GL, IECEx |
Hold time at 120 V ac, typical full load | 26 ms |
Hold time at 230 V ac, typical full load | 26 ms |
IP class | IP20 |
Clamp type | Screw |
Material protection | Aluminium |
Supply frequency | 50-60 ±6 % |
Ripple max | 50 mV pp |
Series | Dimension C |
Power consumption 120 V ac | 4,36 A |
Power consumption 230 V ac | 2,33 A |
Power drop from +60 °C to + 70 °C | 12 W/°C |
Temperature min without derating | -25 °C |
Temperature max without derating | 60 °C |
Type Power Supply | AC-DC |
DC relay output | Yes |
Active Transient | Yes |
Puls Dimension C-series stands for cost optimization without compromising quality, reliability or performance. CPS20.481 high efficiency over a wide load range, which results in reduced power consumption and longer life regardless of load current. An average efficiency is 92.8% with a peak value of 93.9%. In addition, power losses very low at idle, only 2.4 W at 230 V ac.
Short-circuit currents. CPS20 can leave short-circuit currents which is 4 times the nominal current for 15 ms, which helps secondary fuses and achieve selectivity.
Hiccup Plus.
With new pulse short circuit protection you get optimum protection. The unit leaves a very high short circuit that solves fuses and provides sufficient starting current for example dc motors. If the output voltage drops below 25 V DC will be left 2x rated current for 2 seconds, then close the unit by the end to make a new restart attempts after about 18 seconds. This feature ensures a high short-circuit/overload current while avoiding a constant high current that can lead to heat and component damage.
Technical advantages. CPS20 has active power factor correction (PFC) and active power inrush protection that effectively reduces start currents which are ideal if several units are connected in the same phase or if the supply is current limited through example. AC UPS. The protection is always active, regardless of the temperature. DC-OK output, wide temperature range, a large number of approvals and transient filter which ensures operation in störrik electrical environment makes the unit suitable for virtually all installations.
Â
For approved cooling, we recommend free space of 40 mm above. 20 mm under and 5 mm on the sides. (15 mm if there is another power supply)
Â
   |
Â
Â
This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.
We are thrilled to announce the launch of IATECH, THe Industrial Automation Technology expo at Leicester Marriott Hotel on 23rd October. The ultimate platform for showcasing our extensive product range and broad business areas, featuring over 50 leading suppliers under one roof!
The specialist vehicle industry can include automotive and EV, heavy vehicles such as agriculture and rail, and marine. This email takes you through some of the various products we offer for specialist vehicle applications.
This blog post delves into the key components, current trends, and best practices in power distribution, illustrating the significant impact these systems have on our daily operations and long-term energy strategies.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Input voltage ac | Input voltage ac min | Input voltage ac max | Input voltage dc | Input voltage dc min | Input voltage dc max | Inrush current | Inrush current at 120 V ac typical | Inrush current at 230 V ac typical | Input voltage range | Max entrance tripple | Power factor at 120 V ac, full load. Typical | Power factor at 230 V ac, full load. Typical | Number of phases | Efficiency | Efficiency at 120 V ac, full load, typical | Efficiency at 230 V ac, typical | Efficiency at 230 V ac, full load, typical | Lifetime at 120 V ac, full load and +40 ° C | Lifetime at 230 V ac, full load and +40 ° C | MTBF (IEC 61709) | MTBF (IEC 61709) 230 V ac, max load, 40 ° C | Weight | Approvals | Keep time | Hold time at 120 V ac, typical full load | Hold time at 230 V ac, typical full load | Supply frequency | Power consumption 120 V ac | Power consumption 230 V ac | Startup delay | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PSU 100-240V ac I/P 48V dc 10A 480W O/P
Art:
CPS20.481
Copied
|
100-240 V
|
100 V AC
|
264 V AC
|
|
|
|
|
9 A
|
7 A
|
Wide-range
|
|
0,99
|
0,95
|
1
|
|
92,6 %
|
92,8 %
|
93,9 %
|
70000 h
|
87000 h
|
|
537000 h
|
1 kg
|
ABS, ATEX, CB, CE, CSA US, cRUus, cULus, GL, IECEx
|
|
26 ms
|
26 ms
|
50-60 ±6 %
|
4,36 A
|
2,33 A
|
|
| ||
PSU 110-300V dc I/P 48V dc 10A 480W O/P
Art:
CPS20.481-D1
Copied
|
|
|
|
110-300 V
|
88 V DC
|
360 V DC
|
Typ. 6/4 A @ 110/300 V DC
|
|
|
|
50 V pp
|
|
|
|
94,6 %
|
|
|
|
|
|
537000 h @ 10 A, 40 °C
|
|
0,94 kg
|
ATEX, CB, CE, CSA US, cRUus, cULus, IECEx
|
Typ. 26/26 ms @ 110/300 V DC
|
|
|
|
|
|
1100 ms
|
|
Select a variant in the list