PULS

Power supply 1-Phase, Miniline Series 1

Puls series Miniline is characterised by compact dimensions, reliability and long lifetime with high efficiency, which entails low energy loss and low temperatures in the switch cabinet. The power supply units are just 45 mm wide and feature spring connection, which means faster installation. For more technical information, consult the general information at the beginning of the power supply section.

 

Read more
  • Output current of 1 A or 7.5 A
  • High efficiency
  • Space-saving
  • Manages high starting/overload currents
  • 5 V - 48 V DC

Selected variant

Selected variant

Technical data

Input data

Input voltage ac 100-240 V
Input voltage ac min 85 V AC
Input voltage ac max 264 V AC
Input voltage dc 110-300 V
Input voltage dc min 85 V DC
Input voltage dc max 370 V DC
Inrush current at 120 V ac typical 17 A
Inrush current at 230 V ac typical 35 A
Input voltage range Wide-range
Power factor at 120 V ac, full load. Typical 0,51
Power factor at 230 V ac, full load. Typical 0,44
Number of phases 1

Output data

Output voltage 5 V DC
Output voltage min 5 V DC
Output voltage max 5,5 V DC
Output current 5 A
Power 25 W

Efficiency / Lifetime / MTBF

Efficiency at 230 V ac, full load, typical 80 %
MTBF (IEC 61709) 230 V ac, max load, 40 ° C 1963000 h

Dimensions

Width 45 mm

*Invisible Heading*

Height 75 mm
Depth 91 mm
Weight 0,24 kg

Other

Approvals CB, CE, CSA, GL, NEC Class 2, UL
Hold time at 120 V ac, typical full load 22 ms
Hold time at 230 V ac, typical full load 170 ms
IP class IP20
Clamp type Spring-clamp
Material protection ABS plastic
Supply frequency 50-60 ±6 %
Ripple max 50 mV pp
Series Miniline
Power consumption 120 V ac 0,6 A
Power consumption 230 V ac 0,35 A
Power drop from +60 °C to + 70 °C 0,5 W/°C
Temperature min without derating -10 °C
Temperature max without derating 60 °C
Type Power Supply AC-DC

Product description

Puls series Miniline is characterised by compact dimensions, reliability and long lifetime with high efficiency, which entails low energy loss and low temperatures in the switch cabinet. The power supply units are just 45 mm wide and feature spring connection, which means faster installation. For more technical information, consult the general information at the beginning of the power supply section.

 

Accessories

Related products

Related

DC circuit protection PISA M and circuit breakers
Knowledge

Safeguard systems with DC circuit protection

This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.

IATECH, the industrial automation technology exhibition OEM automatic
Company news

Recap of IATECH

Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.

zoller and frohlich cable preparation machines
Product news Blog

Book your Cable Preparation Machinery Demo at OEM

To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.

IATECH industrial automation components exhibition in at leicester marriott hotel by OEM Automatic
Company news

OEM introduces IATECH - The Industrial Automation Technology Expo

We are thrilled to announce the launch of IATECH, THe Industrial Automation Technology expo at Leicester Marriott Hotel on 23rd October. The ultimate platform for showcasing our extensive product range and broad business areas, featuring over 50 leading suppliers under one roof!

automation components for specialist vehicles
Blog

Automation Components for Specialist Vehicles

The specialist vehicle industry can include automotive and EV, heavy vehicles such as agriculture and rail, and marine.  This email takes you through some of the various products we offer for specialist vehicle applications.

Wohner power distribution
Product news Blog

Modern Power Distribution

This blog post delves into the key components, current trends, and best practices in power distribution, illustrating the significant impact these systems have on our daily operations and long-term energy strategies.

Parts Input voltage ac Input voltage dc Input voltage dc min Input voltage dc max Inrush current at 120 V ac typical Inrush current at 230 V ac typical Input voltage range Power factor at 120 V ac, full load. Typical Power factor at 230 V ac, full load. Typical Output voltage Output voltage min Output voltage max Output current Power Efficiency at 230 V ac, full load, typical MTBF (IEC 61709) 230 V ac, max load, 40 ° C Width Depth Weight Power reserve Approvals Hold time at 120 V ac, typical full load Hold time at 230 V ac, typical full load PFA (EN61000-3-2) Ripple max Voltage regulation Power consumption 120 V ac Power consumption 230 V ac Power drop from +60 °C to + 70 °C Active Transient Conformal coated Price
100-240 V
110-300 V
85 V DC
370 V DC
17 A
35 A
Wide-range
0,51
0,44
5 V DC
5 V DC
5,5 V DC
5 A
25 W
80 %
1963000 h
45 mm
91 mm
0,24 kg
CB, CE, CSA, GL, NEC Class 2, UL
22 ms
170 ms
50 mV pp
0,6 A
0,35 A
0,5 W/°C
100-240 V
110-300 V
85 V DC
375 V DC
17 A
35 A
Wide-range
0,53
0,53
12 V DC
10 V DC
12 V DC
2,5 A
30 W
84 %
650000 h
45 mm
91 mm
0,24 kg
CB, CE, CSA, NEC Class 2, UL
18 ms
170 ms
10 mV pp
0,6 A
0,25 A
0,8 W/°C
Yes
100-240 V
110-300 V
85 V DC
375 V DC
17 A
35 A
Wide-range
0,53
0,53
12 V DC
12 V DC
15 V DC
2,5 A
30 W
86 %
600000 h
45 mm
91 mm
0,24 kg
CB, CE, CSA, GL, NEC Class 2, UL
18 ms
180 ms
50 mV pp
0,65 A
0,4 A
1 W/°C
Yes
100-240 V
110-300 V
85 V DC
375 V DC
17 A
35 A
Wide-range
0,52
0,52
12 V DC
12 V DC
15 V DC
4,2 A
50 W
90 %
650000 h
45 mm
91 mm
0,26 kg
CB, CE, CSA, NEC Class 2, UL
17 ms
170 ms
100 mV pp
1 A
0,6 A
1,3 W/°C
Yes
100-240 V
110-300 V
85 V DC
375 V DC
17 A
35 A
Wide-range
0,52
0,52
48 V DC
48 V DC
56 V DC
1,05 A
50 W
90 %
600000 h
45 mm
91 mm
0,24 kg
None
CB, CE, CSA, NEC Class 2, UL
17 ms
170 ms
Yes
50 mV pp
<1.0% of output voltage
1 A
0,6 A
1,3 W/°C
100-120, 220-240 V
290 V
220 V DC
375 V DC
26 A
30 A
Switch
0,54
0,54
24 V DC
24 V DC
28 V DC
3 A
72 W
89 %
600000 h
45 mm
91 mm
0,26 kg
CB, CE, CSA, GL, NEC Class 2, UL
25 ms
40 ms
50 mV pp
1,6 A
0,8 A
1,8 W/°C
100-120, 220-240 V
290 V
220 V DC
375 V DC
22 A
37 A
Auto-select
0,55
0,55
24 V DC
24 V DC
28 V DC
3,9 A
95 W
90 %
500000 h
73 mm
103 mm
0,36 kg
CB, CE, CSA, NEC Class 2, UL
20 ms
40 ms
50 mV pp
2 A
0,95 A
2 W/°C
100-120, 220-240 V
290 V
220 V DC
375 V DC
22 A
37 A
Auto-select
0,55
0,55
24 V DC
24 V DC
28 V DC
4,2 A
100 W
90 %
500000 h
73 mm
103 mm
0,36 kg
CB, CE, CSA, GL, UL
20 ms
40 ms
50 mV pp
2,1 A
1 A
2,5 W/°C
100-120, 220-240 V
290 V
220 V DC
375 V DC
22 A
37 A
Auto-select
0,55
0,55
12 V DC
12 V DC
15 V DC
7,5 A
90 W
88,5 %
500000 h
73 mm
103 mm
0,36 kg
CB, CE, CSA, GL, UL
20 ms
40 ms
50 mV pp
1,9 A
0,9 A
2,5 W/°C
Yes
100-120, 220-240 V
290 V
220 V DC
375 V DC
22 A
37 A
Auto-select
0,55
0,55
48 V DC
48 V DC
56 V DC
2,1 A
100 W
91 %
500000 h
73 mm
103 mm
0,36 kg
None
CB, CE, CSA, GL, UL
20 ms
40 ms
50 mV pp
2,1 A
1 A
2,5 W/°C
100-120, 220-240 V
290 V
220 V DC
375 V DC
22 A
37 A
Auto-select
0,55
0,55
24 V DC
24 V DC
28 V DC
4,2 A
100 W
90 %
500000 h
73 mm
103 mm
0,36 kg
CB, CE, CSA, GL, UL
20 ms
40 ms
50 mV pp
2,1 A
1 A
2,5 W/°C
Yes

Selected variant

Select a variant in the list

Contact us
If you need any help, you can contact us in one of the following ways:
0116 284 9900
Send e-mail
Use live chat
Do you need help?
Logo

Cookie settings for OEM.CO.UK

Cookies help us improve your experience with us, so in order to be able to handle login information, offer you personalised content and for basic functionality of this website, we use some cookies.

We will never sell on any information about you. 

You can accept all cookies or personalise your cookies preferences, you can also change your cookie preferences at any time by visiting our contact page.

Necessary Cookies

These cookies are necessary for the website to work and can not be turned off in our systems. They are usually used only in response to actions you have taken in connection with a service request, for example when setting personal preferences, logging in or filling out a form.

Analysis and measurement cookies

These cookies allow us to count the number of visits and traffic sources so that we can measure and improve our website performance. They help us know which pages are more or less popular and how visitors navigate around the site. The information that these cookies collect is aggregated and therefore completely anonymous. If you do not allow these cookies, we do not know when you have visited our website.

Marketing cookies

These cookies can be added by our partners. They can use them to create a profile of you, based on your interests, to show you more relevant information. They do not store any personal information - only information about your browser and device. If you do not accept these cookies, you will have a more general and less customized user experience.