The ML100.200 is a simple and cost effective approach to convert the ac voltage of a typical three phase system into a regulated dc voltage. It only requires two phases and thereby saves terminal space, terminal cost, wires, fuses and installation time.
The ML100.200 is very compact, high efficient and easy to use. The input is internally protected, which makes external fuses unnecessary in many cases.
Weighing only 360g, it is a lightweight compared to the 50/60Hz control transformers, which are commonly used for low-power control voltages where a neutral wire is not available.
High immunity to transients and power surges as well as low electromagnetic emission makes usage in nearly every environment possible.
For approved cooling, free space of 40 mm above and 20 mm under is recommended.
If adjacent components on the rail radiate heat, free space of 15 mm is recommended at all sides.
Â
Input data |
|
---|---|
Input voltage ac | 380-480 V |
Input voltage ac min | 323 V AC |
Input voltage ac max | 552 V AC |
Inrush current at 400 V ac typical | 36 A |
Input voltage range | Wide-range |
Power factor at 400 V ac, full load. Typical | 0,6 |
Number of phases | 2 |
Output data |
|
Output voltage | 24 V DC |
Output voltage min | 24 V DC |
Output voltage max | 28 V DC |
Output current | 3,75 A |
Power | 90 W |
Efficiency / Lifetime / MTBF |
|
Efficiency at 400 V ac, full load, typical | 89,5 % |
MTBF (IEC 61709) 400 V ac, max loan, +40 °C | 1594000 h |
Dimensions |
|
Width | 72,5 mm |
Height | 75 mm |
*Invisible Heading* |
|
---|---|
Depth | 103 mm |
Weight | 0,36 kg |
Other |
|
Approvals | CB, CE, CSA, GL, NEC Class 2, UL |
Hold time at 400 V ac, typical full load | 52 ms |
IP class | IP20 |
Clamp type | Spring-clamp |
Material protection | ABS plastic |
Supply frequency | 50-60 ±6 % |
Ripple max | 50 mV pp |
Series | Miniline |
Power consumption at 400 V ac | 0,42 A |
Power drop from +60 °C to + 70 °C | 2 W/°C |
Temperature min without derating | -10 °C |
Temperature max without derating | 60 °C |
Type Power Supply | AC-DC |
The ML100.200 is a simple and cost effective approach to convert the ac voltage of a typical three phase system into a regulated dc voltage. It only requires two phases and thereby saves terminal space, terminal cost, wires, fuses and installation time.
The ML100.200 is very compact, high efficient and easy to use. The input is internally protected, which makes external fuses unnecessary in many cases.
Weighing only 360g, it is a lightweight compared to the 50/60Hz control transformers, which are commonly used for low-power control voltages where a neutral wire is not available.
High immunity to transients and power surges as well as low electromagnetic emission makes usage in nearly every environment possible.
For approved cooling, free space of 40 mm above and 20 mm under is recommended.
If adjacent components on the rail radiate heat, free space of 15 mm is recommended at all sides.
Â
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.
We are thrilled to announce the launch of IATECH, THe Industrial Automation Technology expo at Leicester Marriott Hotel on 23rd October. The ultimate platform for showcasing our extensive product range and broad business areas, featuring over 50 leading suppliers under one roof!
The specialist vehicle industry can include automotive and EV, heavy vehicles such as agriculture and rail, and marine. This email takes you through some of the various products we offer for specialist vehicle applications.
This blog post delves into the key components, current trends, and best practices in power distribution, illustrating the significant impact these systems have on our daily operations and long-term energy strategies.
We shine a spotlight on surge protection devices (SPDs), a crucial yet often overlooked component in industrial settings. Every surge of electricity, every fluctuation in voltage, poses a potential threat to your machinery and systems.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Output current | Power | Approvals | Hold time at 400 V ac, typical full load | Power consumption at 400 V ac | Power drop from +60 °C to + 70 °C | Price | ||
---|---|---|---|---|---|---|---|---|---|
PSU 3PH 380-480V ac I/P 24V dc 3.75A 90W O/P
Art:
ML90.200
Copied
|
3,75 A
|
90 W
|
CB, CE, CSA, GL, NEC Class 2, UL
|
52 ms
|
0,42 A
|
2 W/°C
|
| ||
PSU 3PH 380-480V ac I/P 24V dc 4A 100W O/P
Art:
ML100.200
Copied
|
4,2 A
|
100 W
|
CB, CE, CSA, GL, UL
|
48 ms
|
0,46 A
|
2,5 W/°C
|
|