PULS
Puls Dimension C is a series of very high quality, reliability and performance.
CT10 has built primary fuses that make it possible to connect the unit without the need for intermediate fuses up to 32 A (UL) which saves space and money.
The efficiency is high over a wide load range, which results in reduced power consumption and longer life regardless of load current. An average efficiency of 50% to 100% load is 92% with a peak value of 92.8%.
The short circuit current is 3 x rated current for 20 ms, which helps secondary fuses. Power boost of 20% enables higher current extraction without voltage drops. This is especially useful during start-ups and to bridge the current peaks in the application. Power can be used continually up to +45°C and short periods from +45°C to +60°C.
Active transient ensure operation also in very interference rich electrical environment in addition, CT10 active inrush current protection, which means a very low starting current, even if the unit has been in operation for a longer time. Especially useful for redundant/parallel-connected systems.
Power supply connected with 3 stages but can operate on only two phases, taking into account the loading and ambient temperature.
We recommend free space of 40 mm above and 20 mm below the unit, and 5 mm on the sides.
Power reserve |
Input data |
|
---|---|
Input voltage ac | 380-480 V |
Input voltage ac min | 323 V AC |
Input voltage ac max | 576 V AC |
Input voltage dc min | 450 V DC |
Input voltage dc max | 780 V DC |
Inrush current at 400 V ac typical | 4 A |
Input voltage range | Wide-range |
Power factor at 400 V ac, full load. Typical | 0,53 |
Number of phases | 3 |
Output data |
|
Output voltage | 48 V DC |
Output voltage min | 48 V DC |
Output voltage max | 56 V DC |
Output current | 5 A |
Power | 240 W |
Efficiency / Lifetime / MTBF |
|
Efficiency at 400 V ac, typical | 92 % |
Efficiency at 400 V ac, full load, typical | 92,8 % |
Lifetime at 400 V ac, full load and +40 ° C | 122000 h |
MTBF (IEC 61709) 400 V ac, max loan, +40 °C | 1051000 h |
Dimensions |
|
Width | 62 mm |
*Invisible Heading* |
|
---|---|
Height | 124 mm |
Depth | 117 mm |
Weight | 0,75 kg |
Other |
|
Approvals | ABS, CB, CE, CSA US, cRUus, cULus, GL |
Hold time at 400 V ac, typical full load | 34 ms |
IP class | IP20 |
Clamp type | Screw |
Material protection | Aluminium |
Supply frequency | 50-60 ±6 % |
Ripple max | 50 mV pp |
Series | Dimension C |
Power consumption at 400 V ac | 0,7 A |
Power drop from +60 °C to + 70 °C | 6 W/°C |
Temperature min without derating | -25 °C |
Temperature max without derating | 60 °C |
Type Power Supply | AC-DC |
Active Transient | Yes |
Puls Dimension C is a series of very high quality, reliability and performance.
CT10 has built primary fuses that make it possible to connect the unit without the need for intermediate fuses up to 32 A (UL) which saves space and money.
The efficiency is high over a wide load range, which results in reduced power consumption and longer life regardless of load current. An average efficiency of 50% to 100% load is 92% with a peak value of 92.8%.
The short circuit current is 3 x rated current for 20 ms, which helps secondary fuses. Power boost of 20% enables higher current extraction without voltage drops. This is especially useful during start-ups and to bridge the current peaks in the application. Power can be used continually up to +45°C and short periods from +45°C to +60°C.
Active transient ensure operation also in very interference rich electrical environment in addition, CT10 active inrush current protection, which means a very low starting current, even if the unit has been in operation for a longer time. Especially useful for redundant/parallel-connected systems.
Power supply connected with 3 stages but can operate on only two phases, taking into account the loading and ambient temperature.
We recommend free space of 40 mm above and 20 mm below the unit, and 5 mm on the sides.
Power reserve |
Do you require signalling devices and beacons in your production process? Download our latest whitepaper!
Here, our customer requires control boxes for electricity metering systems. We leveraged our expertise to deliver easy-to-install, ready-to-use assemblies. We look forward to creating more of these bespoke control boxes for our customer.
This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.
We are thrilled to announce the launch of IATECH, THe Industrial Automation Technology expo at Leicester Marriott Hotel on 23rd October. The ultimate platform for showcasing our extensive product range and broad business areas, featuring over 50 leading suppliers under one roof!