PULS
Pulse Dimension Q is a series power supply with very high performance. The efficiency is high over a wide load range, which results in reduced power consumption and longer life regardless of load current. The average efficiency is 94.2% with a peak of 95%. The power loss at idle is only 12 W.
The bonus power provides 50% extra reserve with retained 48 V DC (30 A) which is an advantage when connected loads have high starting currents and to bridge temporary current peaks. The bonus power is limited to 4 seconds to avoid constant overloading of the power supply and wiring. In addition to the bonus effect leave the unit a very high short-circuit current (ms) that helps to secondary fuses. If the overload remains after 4 sec. Ports end in the so called, hiccup mode. When the output voltage drops below 40 V dc shut the unit by the end of the 18's. And then make a new start attempt. If the overload / short connection is gone restarts the power supply automatically. If the overload / short circuit persists, the unit output current of approx. 2 sec and then again turn off.
Heavy transient assure operation even at very störrik electrical environment and also has QS40.484 active inrush current protection, which means a very low starting current, even if the unit has been in operation for a longer time. Especially useful for redundant / parallel-connected systems.
Simple diagnostics via DC-OK relay that falls on the output voltage deviates more than 10% from the set value, a green LED indicates DC-OK, Red LED indicates overload.
The unit can also be remote controlled for on/off function. Three different installation options available, see the "Technical data". Can be used instead of expensive DC contactors when you need to break up the 48 V side (NB. The remote control function has no safety circuit and therefore should not be used in the security context).
Active PFC reduces power consumption, harmonics close to zero and in addition, the power distribution in phases much smoother at power asymmetry.
Â
We recommend free space of 40 mm over 20 mm below the unit, as well as 15 mm on the sides.
Â
Â
Output charcteristic |
Remote control function |
Â
Bonus power
The power supply has a bonus power that enables high power output with maintained 48 V DC for 4 seconds, which is a big advantage when connected loads have high starting current, e.g. motors. How often you can use the bonus power depends on the application. With the diagram and formula below you can calculate the available repeat time for each application. Bonus power is available as soon as the power supply starts and immediately after a short circuit.
Â
Bonus power | Operating cycle | |
Po | Nominal load current | |
Ppeak | Peak current | |
To | Time between bonus power | |
Tpeak | Peak current I time | |
Operating cycle | Tpeak/(Tpeak+To) | |
To= | Tpeak-(operating cycle*Tpeak)/operating cycle | |
E.g. Peak current (Ppeak) is 25A =125 %. Peak time is 3 seconds. Nominal load current (Po) is 15A. 15A =75 % of Inom. According to the diagram the operating cycle is about 0.45. To=3 - (0.45*3) / 0.45=3.6. Maximal repeat time of the bonus power is 3.6 seconds |
Â
Switching | |||
Function | Overload | DC OK | DC OK |
Normal operation | Off | On | Closed |
During bonus power output | Off | On | Closed |
Overload (Hick-up) | Blinks | Off | Open |
Short circuit | Blinks | Off | Open |
Over temperature | Blinks | Off | Open |
Remote shutdown | Blinks | Off | Open |
No input voltage | Off | Off | Open |
Â
Input data |
|
---|---|
Input voltage ac | 200-240 V |
Input voltage ac min | 170 V AC |
Input voltage ac max | 264 V AC |
Number of phases | 1 |
Inrush current at 230 V ac typical | 14 A |
Power factor at 230 V ac, full load. Typical | 0,96 |
Output data |
|
Output voltage min | 48 V DC |
Output voltage | 48 V DC |
Output voltage max | 54 V DC |
Power | 960 W |
Output current | 20 A |
Efficiency / Lifetime / MTBF |
|
MTBF (IEC 61709) 230 V ac, max load, 40 ° C | 392000 h |
Efficiency at 230 V ac, full load, typical | 95 % |
Efficiency at 230 V ac, typical | 94,2 % |
Lifetime at 230 V ac, full load and +40 ° C | 65000 h |
Dimensions |
|
Weight | 1,8 kg |
Depth | 127 mm |
*Invisible Heading* |
|
---|---|
Width | 125 mm |
Height | 124 mm |
Other |
|
IP class | IP20 |
Ripple max | 150 mV pp |
Power drop from +60 °C to + 70 °C | 24 W/°C |
Clamp type | Spring-clamp |
Temperature min without derating | -25 °C |
Series | Dimension Q |
Hold time at 230 V ac, typical full load | 30 ms |
Power consumption 230 V ac | 4,6 A |
Supply frequency | 50-60 ±6 % |
Approvals | ABS, CB, CE, CSA, GL, UL |
Temperature max without derating | 60 °C |
Material protection | Aluminium |
Type Power Supply | AC-DC |
DC relay output | Yes |
Pulse Dimension Q is a series power supply with very high performance. The efficiency is high over a wide load range, which results in reduced power consumption and longer life regardless of load current. The average efficiency is 94.2% with a peak of 95%. The power loss at idle is only 12 W.
The bonus power provides 50% extra reserve with retained 48 V DC (30 A) which is an advantage when connected loads have high starting currents and to bridge temporary current peaks. The bonus power is limited to 4 seconds to avoid constant overloading of the power supply and wiring. In addition to the bonus effect leave the unit a very high short-circuit current (ms) that helps to secondary fuses. If the overload remains after 4 sec. Ports end in the so called, hiccup mode. When the output voltage drops below 40 V dc shut the unit by the end of the 18's. And then make a new start attempt. If the overload / short connection is gone restarts the power supply automatically. If the overload / short circuit persists, the unit output current of approx. 2 sec and then again turn off.
Heavy transient assure operation even at very störrik electrical environment and also has QS40.484 active inrush current protection, which means a very low starting current, even if the unit has been in operation for a longer time. Especially useful for redundant / parallel-connected systems.
Simple diagnostics via DC-OK relay that falls on the output voltage deviates more than 10% from the set value, a green LED indicates DC-OK, Red LED indicates overload.
The unit can also be remote controlled for on/off function. Three different installation options available, see the "Technical data". Can be used instead of expensive DC contactors when you need to break up the 48 V side (NB. The remote control function has no safety circuit and therefore should not be used in the security context).
Active PFC reduces power consumption, harmonics close to zero and in addition, the power distribution in phases much smoother at power asymmetry.
Â
We recommend free space of 40 mm over 20 mm below the unit, as well as 15 mm on the sides.
Â
Â
Output charcteristic |
Remote control function |
Â
Bonus power
The power supply has a bonus power that enables high power output with maintained 48 V DC for 4 seconds, which is a big advantage when connected loads have high starting current, e.g. motors. How often you can use the bonus power depends on the application. With the diagram and formula below you can calculate the available repeat time for each application. Bonus power is available as soon as the power supply starts and immediately after a short circuit.
Â
Bonus power | Operating cycle | |
Po | Nominal load current | |
Ppeak | Peak current | |
To | Time between bonus power | |
Tpeak | Peak current I time | |
Operating cycle | Tpeak/(Tpeak+To) | |
To= | Tpeak-(operating cycle*Tpeak)/operating cycle | |
E.g. Peak current (Ppeak) is 25A =125 %. Peak time is 3 seconds. Nominal load current (Po) is 15A. 15A =75 % of Inom. According to the diagram the operating cycle is about 0.45. To=3 - (0.45*3) / 0.45=3.6. Maximal repeat time of the bonus power is 3.6 seconds |
Â
Switching | |||
Function | Overload | DC OK | DC OK |
Normal operation | Off | On | Closed |
During bonus power output | Off | On | Closed |
Overload (Hick-up) | Blinks | Off | Open |
Short circuit | Blinks | Off | Open |
Over temperature | Blinks | Off | Open |
Remote shutdown | Blinks | Off | Open |
No input voltage | Off | Off | Open |
Â
Engineers and technicians are seeking solutions that streamline assembly whilst maintaining high levels of protection and flexibility. KDS-SR90 angled screw frames and inlays bring a new level of efficiency to cable routing with a unique 90° entry design.
The smallest logic controller by Crouzet is now 20% off for a limited time only! A powerhouse packed into just 17.5mm! Efficiency, adaptability, and seamless integration with free software.
Do you require signalling devices and beacons in your production process? Download our latest whitepaper!
Here, our customer requires control boxes for electricity metering systems. We leveraged our expertise to deliver easy-to-install, ready-to-use assemblies. We look forward to creating more of these bespoke control boxes for our customer.
This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Input voltage range | Input voltage ac | Input voltage ac min | Inrush current at 230 V ac typical | Inrush current at 120 V ac typical | Power factor at 120 V ac, full load. Typical | Power factor at 230 V ac, full load. Typical | Lifetime at 120 V ac, full load and +40 ° C | MTBF (IEC 61709) 230 V ac, max load, 40 ° C | Efficiency at 230 V ac, typical | Lifetime at 230 V ac, full load and +40 ° C | Efficiency at 120 V ac, full load, typical | Weight | Power consumption 120 V ac | Hold time at 120 V ac, typical full load | Hold time at 230 V ac, typical full load | Power consumption 230 V ac | Approvals | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]()
POWER SUPPLY 200-240V/48VDC 20A
Art:
QS40.484
Copied
|
|
200-240 V
|
170 V AC
|
14 A
|
|
|
0,96
|
|
392000 h
|
94,2 %
|
65000 h
|
|
1,8 kg
|
|
|
30 ms
|
4,6 A
|
ABS, CB, CE, CSA, GL, UL
|
| ||
![]()
POWER SUPPLY 100-240V/48VDC 20A
Art:
QS40.481
Copied
|
Wide-range
|
100-240 V
|
90 V AC
|
11 A
|
17 A
|
0,99
|
0,99
|
68000 h
|
300000 h
|
93,9 %
|
90000 h
|
93,9 %
|
1,9 kg
|
8,6 A
|
27 ms
|
27 ms
|
4,5 A
|
ABS, CB, CE, CSA, EX, GL, IECEx, UL
|
|