PULS
The power supply units supply the AS-Interface system with power via the yellow AS-Interface cable. Communications between the various slaves are modulated and are embedded in the power supply's output voltage. A special power supply is therefore required that does not filter out the data information.
The IR addressing mode is selectable via a switch on the front. When the IR mode is activated, communications are disconnected on the yellow AS-Interface cable. The slaves in the loop can then be simply readdressed without physical disconnection from the interface cable. Once programming is completed, the power supply unit is connected for communications mode and data communications is restarted.
Earth fault monitoring: SLA4 has earth fault monitoring between the AS-Interface cable and earth. In the event of short circuiting between +30.5 V dc or minus to earth, the power supply unit will indicate an alarm via a relay contact and a flashing LED. The power supply unit will continue to supply power to the connected slaves when a fault is detected. The fault is acknowledged by pressing a button on the front of the unit. If a separate earthis not installed between the machine and SLA4.100, we recommend earthing the Shield input via the primary side's earth. Do not leave the Shield connection open.
Fuse mode: SLA8 has a fuse mode. In the event of a short circuit, the power supply unit will produce a high short-circuit current for a few seconds (max. 5 s). The unit will then trip its electronic fuse. A tripped fuse is indicated by a flashing LED. To reset the unit, press the reset button at the front. This function entails that unintentional restarts are prevented and the connected units are protected from damage. For more technical information, see the general information section at the beginning of the power supply chapter.
Â
Input data |
|
---|---|
Input voltage ac | 100-120, 220-240 V |
Input voltage ac min | 85 V AC |
Input voltage ac max | 264 V AC |
Inrush current at 120 V ac typical | 20 A |
Inrush current at 230 V ac typical | 38 A |
Input voltage range | Auto-select |
Power factor at 120 V ac, full load. Typical | 0,5 |
Power factor at 230 V ac, full load. Typical | 0,5 |
Output data |
|
Output voltage | 30,55 V DC |
Output voltage min | 30,55 V DC |
Output voltage max | 30,55 V DC |
Output current | 2,8 A |
Efficiency / Lifetime / MTBF |
|
Efficiency at 230 V ac, full load, typical | 90,5 % |
MTBF (IEC 61709) 230 V ac, max load, 40 ° C | 1942000 h |
Dimensions |
|
Width | 49 mm |
Height | 124 mm |
Depth | 102 mm |
*Invisible Heading* |
|
---|---|
Weight | 0,5 kg |
Other |
|
Approvals | CB, CE, CSA, NEC Class 2, UL |
Hold time at 120 V ac, typical full load | 26 ms |
Hold time at 230 V ac, typical full load | 26 ms |
IP class | IP20 |
Material protection | Aluminium |
Supply frequency | 50-60 ±6 % |
Ripple max | 50 mV pp |
Series | Silverline |
Power consumption 120 V ac | 2 A |
Power consumption 230 V ac | 0,9 A |
Power drop from +60 °C to + 70 °C | 2 W/°C |
Temperature min without derating | -10 °C |
Temperature max without derating | 60 °C |
Type Power Supply | AS-Interface |
The power supply units supply the AS-Interface system with power via the yellow AS-Interface cable. Communications between the various slaves are modulated and are embedded in the power supply's output voltage. A special power supply is therefore required that does not filter out the data information.
The IR addressing mode is selectable via a switch on the front. When the IR mode is activated, communications are disconnected on the yellow AS-Interface cable. The slaves in the loop can then be simply readdressed without physical disconnection from the interface cable. Once programming is completed, the power supply unit is connected for communications mode and data communications is restarted.
Earth fault monitoring: SLA4 has earth fault monitoring between the AS-Interface cable and earth. In the event of short circuiting between +30.5 V dc or minus to earth, the power supply unit will indicate an alarm via a relay contact and a flashing LED. The power supply unit will continue to supply power to the connected slaves when a fault is detected. The fault is acknowledged by pressing a button on the front of the unit. If a separate earthis not installed between the machine and SLA4.100, we recommend earthing the Shield input via the primary side's earth. Do not leave the Shield connection open.
Fuse mode: SLA8 has a fuse mode. In the event of a short circuit, the power supply unit will produce a high short-circuit current for a few seconds (max. 5 s). The unit will then trip its electronic fuse. A tripped fuse is indicated by a flashing LED. To reset the unit, press the reset button at the front. This function entails that unintentional restarts are prevented and the connected units are protected from damage. For more technical information, see the general information section at the beginning of the power supply chapter.
Â
This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.
We are thrilled to announce the launch of IATECH, THe Industrial Automation Technology expo at Leicester Marriott Hotel on 23rd October. The ultimate platform for showcasing our extensive product range and broad business areas, featuring over 50 leading suppliers under one roof!
The specialist vehicle industry can include automotive and EV, heavy vehicles such as agriculture and rail, and marine. This email takes you through some of the various products we offer for specialist vehicle applications.
This blog post delves into the key components, current trends, and best practices in power distribution, illustrating the significant impact these systems have on our daily operations and long-term energy strategies.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Inrush current at 120 V ac typical | Inrush current at 230 V ac typical | Power factor at 120 V ac, full load. Typical | Power factor at 230 V ac, full load. Typical | Output voltage min | Output voltage max | Output current | Efficiency at 230 V ac, full load, typical | MTBF (IEC 61709) 230 V ac, max load, 40 ° C | Width | Weight | Approvals | Hold time at 120 V ac, typical full load | Hold time at 230 V ac, typical full load | Power consumption 120 V ac | Power consumption 230 V ac | Power drop from +60 °C to + 70 °C | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ASI PSU 100-120/220-240V ac I/P 30.5V dc 2.8A O/P
Art:
SLA3.100
Copied
|
20 A
|
38 A
|
0,5
|
0,5
|
30,55 V DC
|
30,55 V DC
|
2,8 A
|
90,5 %
|
1942000 h
|
49 mm
|
0,5 kg
|
CB, CE, CSA, NEC Class 2, UL
|
26 ms
|
26 ms
|
2 A
|
0,9 A
|
2 W/°C
|
| ||
ASI PSU 100-120/220-240V ac I/P 30.5V dc 4A O/P
Art:
SLA4.100
Copied
|
45 A
|
50 A
|
0,53
|
0,53
|
30,5 V DC
|
30,5 V DC
|
4 A
|
88 %
|
1222000 h
|
65 mm
|
0,62 kg
|
CB, CE, CSA, UL
|
30 ms
|
30 ms
|
2,7 A
|
1,3 A
|
3 W/°C
|
| ||
ASI PSU 100-120/220-240V ac I/P 30.5V dc 8A O/P
Art:
SLA8.100
Copied
|
14 A
|
25 A
|
0,48
|
0,48
|
30,5 V DC
|
30,5 V DC
|
8 A
|
92 %
|
869000 h
|
91 mm
|
0,89 kg
|
CB, CE, CSA, UL
|
10 ms
|
10 ms
|
6 A
|
2,8 A
|
6 W/°C
|
|
Select a variant in the list