PULS
Redundant modules have MOSFET transistors instead of diodes, resulting in lower heat dissipation and voltage drop. Thanks to the MOSFET technology, the modules can be made very compact.
Redundant modules have two separate entrances, each of which can be loaded with half the output current instance. 40 A module can handle up to 20 A per input.
With redundant modules from Pulse, you get a secure system against internal power supply faults which are particularly suitable in processes where downtime is costly.
Redundant module can also be used in systems where you want to ensure the operation of sensitive loads. Input 1 is connected to the main power supply that normally supplies loads directly and eg PLC via redundant module output. Input 2 is connected to a smaller unit that is only connected to the sensitive load via the output, in this case the PLC. In case of failure of the main unit or short circuit at the loads going PLC supplied by the smaller unit and avoids incorrect processavslut. Redundant module is also suitable when you want to separate the power supply units from the loads to avoid returned voltage, for example, from motors and batteries.
Â
Input data |
|
---|---|
Input voltage dc max | 36,4 V DC |
Input voltage dc | 12-28 V |
Input current at continuous overload or short circuit max | 2x32,5 A |
Input current per channel max | 20 A |
Input voltage dc min | 8,4 V DC |
Output data |
|
Output current max | 65 A |
Output voltage | 24 V DC |
Output current | 40 A |
Efficiency / Lifetime / MTBF |
|
Life span | 246000 h @ 2x 20 A, 24 V DC, 40 °C |
MTBF (IEC 61709) | 2706000 h @ 2x 20 A, 24 V DC, 40 °C |
Dimensions |
|
Weight | 0,34 kg |
Depth | 127 mm |
*Invisible Heading* |
|
---|---|
Width | 36 mm |
Height | 124 mm |
Other |
|
IP class | IP20 |
Voltage drop over semiconductor | 140 mV |
Temperature min without derating | -40 °C |
Input / Output Separation | Mosfet |
Series | Dimension Y |
Approvals | ABS, ATEX, CB, CE, CSA, CSA US, GL, IECEx, UL |
Temperature max without derating | 70 °C |
Material protection | Aluminium |
Type Power Supply | Redundancy modules |
Redundant modules have MOSFET transistors instead of diodes, resulting in lower heat dissipation and voltage drop. Thanks to the MOSFET technology, the modules can be made very compact.
Redundant modules have two separate entrances, each of which can be loaded with half the output current instance. 40 A module can handle up to 20 A per input.
With redundant modules from Pulse, you get a secure system against internal power supply faults which are particularly suitable in processes where downtime is costly.
Redundant module can also be used in systems where you want to ensure the operation of sensitive loads. Input 1 is connected to the main power supply that normally supplies loads directly and eg PLC via redundant module output. Input 2 is connected to a smaller unit that is only connected to the sensitive load via the output, in this case the PLC. In case of failure of the main unit or short circuit at the loads going PLC supplied by the smaller unit and avoids incorrect processavslut. Redundant module is also suitable when you want to separate the power supply units from the loads to avoid returned voltage, for example, from motors and batteries.
Â
Engineers and technicians are seeking solutions that streamline assembly whilst maintaining high levels of protection and flexibility. KDS-SR90 angled screw frames and inlays bring a new level of efficiency to cable routing with a unique 90° entry design.
The smallest logic controller by Crouzet is now 20% off for a limited time only! A powerhouse packed into just 17.5mm! Efficiency, adaptability, and seamless integration with free software.
Do you require signalling devices and beacons in your production process? Download our latest whitepaper!
Here, our customer requires control boxes for electricity metering systems. We leveraged our expertise to deliver easy-to-install, ready-to-use assemblies. We look forward to creating more of these bespoke control boxes for our customer.
This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Input current at continuous overload or short circuit max | Input current per channel max | Output current max | Output current | Life span | MTBF (IEC 61709) | Weight | Width | Voltage drop over semiconductor | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|
![]()
REDUNDANCY MODULE 12-28V 40A
Art:
YR40.241
Copied
|
2x32,5 A
|
20 A
|
65 A
|
40 A
|
246000 h @ 2x 20 A, 24 V DC, 40 °C
|
2706000 h @ 2x 20 A, 24 V DC, 40 °C
|
0,34 kg
|
36 mm
|
140 mV
|
| ||
![]()
REDUNDANCY MODULE 12-28V 40A
Art:
YR40.242
Copied
|
2x32,5 A
|
20 A
|
65 A
|
40 A
|
255000 h @ 2x 20 A, 24 V DC, 40 °C
|
4533000 h @ 2x 20 A, 24 V DC, 40 °C
|
0,28 kg
|
36 mm
|
140 mV
|
| ||
![]()
Redundant module 24-28V DC 2 x 40 A
Art:
YR80.241
Copied
|
2x65 A
|
40 A
|
130 A
|
80 A
|
143000 h @ 2x 40 A, 24 V DC, 40 °C
|
2088000 h @ 2x 40 A, 24 V DC, 40 °C
|
0,44 kg
|
46 mm
|
95 mV
|
| ||
![]()
REDUNDANCY MODULE 12-28V 80A
Art:
YR80.242
Copied
|
2x65 A
|
40 A
|
130 A
|
80 A
|
85000 h @ 2x 40 A, 24 V DC, 40 °C
|
2482000 h @ 2x 40 A, 24 V DC, 40 °C
|
0,37 kg
|
46 mm
|
145 mV
|
|
Select a variant in the list