Important notice - Our website is under going construction, therefore you may notice some issues. Please bare with us and contact or customer support team if you need any product information - 0116 284 9900
PULS
Click below link to download the white paper
Efficient redundancy for power supplies
Â
Also visit our page for Redundancy Modules
Â
The Dimension CP-Series are cost optimized power supplies without compromising quality, reliability and performance. The most outstanding features of the CP20.241–R1/-R2/-R3 units are the high efficiency, electronic inrush current limitation, active PFC, wide operational temperature range and the extraordinary small size. The units include a decoupling MOSFET for building 1+1 or n+1 redundant power supply systems.
These redundancy power supplies come with three connection terminal options; screw terminals, spring-clamp terminals or plug connector terminals which allows replacement on an active application.
CP20.242-R2 version feature an enhanced DC input voltage range and the CP20.241-R2-C1 is additionally equipped with conformal coated pc-boards.
CP10.242-R2 version feature an enhanced DC input voltage range.
With high immunity to transients and power surges, low electromagnetic emission, a DC-OK signal contact for remote monitoring, and a large international approval package, makes this unit suitable for nearly every application.Â
Input data |
|
---|---|
Input voltage range | Wide-range |
Input voltage ac | 100-240 V |
Input voltage ac min | 85 V AC |
Input voltage dc max | 180 V DC |
Input voltage dc | 110-150 V |
Input voltage ac max | 264 V AC |
Inrush current at 230 V ac typical | 9 A |
Number of phases | 1 |
Inrush current at 120 V ac typical | 6 A |
Power factor at 120 V ac, full load. Typical | 0,99 |
Power factor at 230 V ac, full load. Typical | 0,97 |
Input voltage dc min | 88 V DC |
Output data |
|
Output voltage min | 24 V DC |
Output voltage | 24 V DC |
Output voltage max | 28 V DC |
Power | 240 W |
Output current | 10 A |
Efficiency / Lifetime / MTBF |
|
Lifetime at 120 V ac, full load and +40 ° C | 78000 h |
MTBF (IEC 61709) 230 V ac, max load, 40 ° C | 641000 h |
Efficiency at 230 V ac, full load, typical | 94,7 % |
Efficiency at 230 V ac, typical | 93,9 % |
Lifetime at 230 V ac, full load and +40 ° C | 109000 h |
*Invisible Heading* |
|
---|---|
Efficiency at 120 V ac, full load, typical | 93 % |
Dimensions |
|
Weight | 0,6 kg |
Depth | 117 mm |
Width | 39 mm |
Height | 124 mm |
Other |
|
IP class | IP20 |
Power consumption 120 V ac | 2,17 A |
Ripple max | 50 mV pp |
Power drop from +60 °C to + 70 °C | 6 W/°C |
Clamp type | Spring-clamp |
Temperature min without derating | -25 °C |
Hold time at 120 V ac, typical full load | 37 ms |
Series | Dimension C |
Hold time at 230 V ac, typical full load | 37 ms |
Power consumption 230 V ac | 1,14 A |
Supply frequency | 50-60 ±6 % |
Approvals | ATEX, CE, CSA US, cULus, IECEx |
Temperature max without derating | 60 °C |
Material protection | Aluminium |
Active Transient | Yes |
DC relay output | Yes |
Click below link to download the white paper
Efficient redundancy for power supplies
Â
Also visit our page for Redundancy Modules
Â
The Dimension CP-Series are cost optimized power supplies without compromising quality, reliability and performance. The most outstanding features of the CP20.241–R1/-R2/-R3 units are the high efficiency, electronic inrush current limitation, active PFC, wide operational temperature range and the extraordinary small size. The units include a decoupling MOSFET for building 1+1 or n+1 redundant power supply systems.
These redundancy power supplies come with three connection terminal options; screw terminals, spring-clamp terminals or plug connector terminals which allows replacement on an active application.
CP20.242-R2 version feature an enhanced DC input voltage range and the CP20.241-R2-C1 is additionally equipped with conformal coated pc-boards.
CP10.242-R2 version feature an enhanced DC input voltage range.
With high immunity to transients and power surges, low electromagnetic emission, a DC-OK signal contact for remote monitoring, and a large international approval package, makes this unit suitable for nearly every application.Â
Engineers and technicians are seeking solutions that streamline assembly whilst maintaining high levels of protection and flexibility. KDS-SR90 angled screw frames and inlays bring a new level of efficiency to cable routing with a unique 90° entry design.
The smallest logic controller by Crouzet is now 20% off for a limited time only! A powerhouse packed into just 17.5mm! Efficiency, adaptability, and seamless integration with free software.
Do you require signalling devices and beacons in your production process? Download our latest whitepaper!
Here, our customer requires control boxes for electricity metering systems. We leveraged our expertise to deliver easy-to-install, ready-to-use assemblies. We look forward to creating more of these bespoke control boxes for our customer.
This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Input voltage dc max | Input voltage dc | Inrush current at 230 V ac typical | Inrush current at 120 V ac typical | Power factor at 230 V ac, full load. Typical | Power | Output current | Lifetime at 120 V ac, full load and +40 ° C | MTBF (IEC 61709) 230 V ac, max load, 40 ° C | Efficiency at 230 V ac, full load, typical | Efficiency at 230 V ac, typical | Lifetime at 230 V ac, full load and +40 ° C | Efficiency at 120 V ac, full load, typical | Weight | Depth | Width | Power consumption 120 V ac | Ripple max | Power drop from +60 °C to + 70 °C | Clamp type | Temperature min without derating | Hold time at 120 V ac, typical full load | Hold time at 230 V ac, typical full load | Power consumption 230 V ac | Approvals | Type Power Supply | Conformal coated | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]()
PSU 24VDC 240W 10A REDUNDANCY
Art:
CP10.241-R1
Copied
|
180 V DC
|
110-150 V
|
9 A
|
6 A
|
0,97
|
240 W
|
10 A
|
78000 h
|
641000 h
|
94,7 %
|
93,9 %
|
109000 h
|
93 %
|
0,6 kg
|
117 mm
|
39 mm
|
2,17 A
|
50 mV pp
|
6 W/°C
|
Spring-clamp
|
-25 °C
|
37 ms
|
37 ms
|
1,14 A
|
ATEX, CE, CSA US, cULus, IECEx
|
|
|
| ||
![]()
POWER SUPPLY 24VDC 240W 10A REDUNDANCY
Art:
CP10.241-R2
Copied
|
180 V DC
|
110-150 V
|
9 A
|
6 A
|
0,97
|
240 W
|
10 A
|
78000 h
|
641000 h
|
94,7 %
|
93,9 %
|
109000 h
|
93 %
|
0,6 kg
|
117 mm
|
39 mm
|
2,17 A
|
50 mV pp
|
6 W/°C
|
Hot-swap
|
-25 °C
|
37 ms
|
37 ms
|
1,14 A
|
ATEX, CE, CSA US, cULus, IECEx
|
Redundant
|
|
| ||
![]()
PSU 24VDC 240W 10A REDUNDANCY WIDE DC
Art:
CP10.242-R2
Copied
|
360 V DC
|
110-300 V
|
9 A
|
6 A
|
0,97
|
240 W
|
10 A
|
78000 h
|
641000 h
|
94,7 %
|
93,9 %
|
109000 h
|
93 %
|
0,6 kg
|
117 mm
|
39 mm
|
2,17 A
|
50 mV pp
|
6 W/°C
|
Hot-swap
|
-25 °C
|
37 ms
|
37 ms
|
1,14 A
|
CB, CE, cULus
|
|
|
| ||
![]()
PSU 24VDC 480W 20A REDUNDANCY
Art:
CP20.241-R1
Copied
|
180 V DC
|
110-150 V
|
4,5 A
|
10 A
|
0,98
|
480 W
|
20 A
|
53000 h
|
543000 h
|
95,2 %
|
94,6 %
|
90000 h
|
93,8 %
|
0,83 kg
|
127 mm
|
48 mm
|
4,28 A
|
100 mV pp
|
12 W/°C
|
Spring-clamp
|
-40 °C
|
32 ms
|
32 ms
|
2,25 A
|
ATEX, CB, CE, CSA US, cRUus, cULus, IECEx
|
|
|
| ||
![]()
PSU 24VDC 480W 20A REDUNDANCY
Art:
CP20.241-R2
Copied
|
180 V DC
|
110-150 V
|
4,5 A
|
10 A
|
0,98
|
480 W
|
20 A
|
53000 h
|
543000 h
|
95,2 %
|
94,6 %
|
90000 h
|
93,8 %
|
0,85 kg
|
127 mm
|
48 mm
|
4,28 A
|
100 mV pp
|
12 W/°C
|
Hot-swap
|
-40 °C
|
32 ms
|
32 ms
|
2,25 A
|
ATEX, CB, CE, cRUus, cULus, IECEx
|
Redundant
|
|
| ||
![]()
PSU 24VDC 480W 20A REDUNDANCY CONF.COAT
Art:
CP20.241-R2-C1
Copied
|
180 V DC
|
110-150 V
|
4,5 A
|
10 A
|
0,98
|
480 W
|
20 A
|
53000 h
|
543000 h
|
95,2 %
|
94,6 %
|
90000 h
|
93,8 %
|
0,85 kg
|
127 mm
|
48 mm
|
4,28 A
|
100 mV pp
|
12 W/°C
|
Hot-swap
|
-40 °C
|
32 ms
|
32 ms
|
2,25 A
|
ATEX, CB, CE, cRUus, cULus, IECEx
|
|
Yes
|
| ||
![]()
Redundant PSU 100-240 VAC/110-300 VDC, 24-28 VDC, 20A
Art:
CP20.242-R2
Copied
|
360 V DC
|
110-300 V
|
4,5 A
|
10 A
|
0,98
|
480 W
|
20 A
|
53000 h
|
543000 h
|
95,2 %
|
94,6 %
|
90000 h
|
93,8 %
|
0,85 kg
|
127 mm
|
48 mm
|
4,28 A
|
100 mV pp
|
12 W/°C
|
Hot-swap
|
-40 °C
|
32 ms
|
32 ms
|
2,25 A
|
CB, CE, cULus
|
|
|
|
Select a variant in the list