PULS
Click below link to download the white paper
Efficient redundancy for power supplies
Â
Also visit our page for Redundancy Modules
Â
The Dimension CP-Series are cost optimized power supplies without compromising quality, reliability and performance. The most outstanding features of the CP20.241–R1/-R2/-R3 units are the high efficiency, electronic inrush current limitation, active PFC, wide operational temperature range and the extraordinary small size. The units include a decoupling MOSFET for building 1+1 or n+1 redundant power supply systems.
These redundancy power supplies come with three connection terminal options; screw terminals, spring-clamp terminals or plug connector terminals which allows replacement on an active application.
CP20.242-R2 version feature an enhanced DC input voltage range and the CP20.241-R2-C1 is additionally equipped with conformal coated pc-boards.
CP10.242-R2 version feature an enhanced DC input voltage range.
With high immunity to transients and power surges, low electromagnetic emission, a DC-OK signal contact for remote monitoring, and a large international approval package, makes this unit suitable for nearly every application.Â
Input data |
|
---|---|
Input voltage ac | 100-240 V |
Input voltage ac min | 85 V AC |
Input voltage ac max | 264 V AC |
Input voltage dc | 110-150 V |
Input voltage dc min | 88 V DC |
Input voltage dc max | 180 V DC |
Inrush current at 120 V ac typical | 6 A |
Inrush current at 230 V ac typical | 9 A |
Input voltage range | Wide-range |
Power factor at 120 V ac, full load. Typical | 0,99 |
Power factor at 230 V ac, full load. Typical | 0,97 |
Number of phases | 1 |
Output data |
|
Output voltage | 24 V DC |
Output voltage min | 24 V DC |
Output voltage max | 28 V DC |
Output current | 10 A |
Power | 240 W |
Efficiency / Lifetime / MTBF |
|
Efficiency at 120 V ac, full load, typical | 93 % |
Efficiency at 230 V ac, typical | 93,9 % |
Efficiency at 230 V ac, full load, typical | 94,7 % |
Lifetime at 120 V ac, full load and +40 ° C | 78000 h |
Lifetime at 230 V ac, full load and +40 ° C | 109000 h |
*Invisible Heading* |
|
---|---|
MTBF (IEC 61709) 230 V ac, max load, 40 ° C | 641000 h |
Dimensions |
|
Width | 39 mm |
Height | 124 mm |
Depth | 117 mm |
Weight | 0,6 kg |
Other |
|
Approvals | ATEX, CE, CSA US, cULus, IECEx |
Hold time at 120 V ac, typical full load | 37 ms |
Hold time at 230 V ac, typical full load | 37 ms |
IP class | IP20 |
Clamp type | Spring-clamp |
Material protection | Aluminium |
Supply frequency | 50-60 ±6 % |
Ripple max | 50 mV pp |
Series | Dimension C |
Power consumption 120 V ac | 2,17 A |
Power consumption 230 V ac | 1,14 A |
Power drop from +60 °C to + 70 °C | 6 W/°C |
Temperature min without derating | -25 °C |
Temperature max without derating | 60 °C |
DC relay output | Yes |
Active Transient | Yes |
Click below link to download the white paper
Efficient redundancy for power supplies
Â
Also visit our page for Redundancy Modules
Â
The Dimension CP-Series are cost optimized power supplies without compromising quality, reliability and performance. The most outstanding features of the CP20.241–R1/-R2/-R3 units are the high efficiency, electronic inrush current limitation, active PFC, wide operational temperature range and the extraordinary small size. The units include a decoupling MOSFET for building 1+1 or n+1 redundant power supply systems.
These redundancy power supplies come with three connection terminal options; screw terminals, spring-clamp terminals or plug connector terminals which allows replacement on an active application.
CP20.242-R2 version feature an enhanced DC input voltage range and the CP20.241-R2-C1 is additionally equipped with conformal coated pc-boards.
CP10.242-R2 version feature an enhanced DC input voltage range.
With high immunity to transients and power surges, low electromagnetic emission, a DC-OK signal contact for remote monitoring, and a large international approval package, makes this unit suitable for nearly every application.Â
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.
We are thrilled to announce the launch of IATECH, THe Industrial Automation Technology expo at Leicester Marriott Hotel on 23rd October. The ultimate platform for showcasing our extensive product range and broad business areas, featuring over 50 leading suppliers under one roof!
The specialist vehicle industry can include automotive and EV, heavy vehicles such as agriculture and rail, and marine. This email takes you through some of the various products we offer for specialist vehicle applications.
This blog post delves into the key components, current trends, and best practices in power distribution, illustrating the significant impact these systems have on our daily operations and long-term energy strategies.
We shine a spotlight on surge protection devices (SPDs), a crucial yet often overlooked component in industrial settings. Every surge of electricity, every fluctuation in voltage, poses a potential threat to your machinery and systems.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Input voltage dc | Input voltage dc max | Inrush current at 120 V ac typical | Inrush current at 230 V ac typical | Power factor at 230 V ac, full load. Typical | Output current | Power | Efficiency at 120 V ac, full load, typical | Efficiency at 230 V ac, typical | Efficiency at 230 V ac, full load, typical | Lifetime at 120 V ac, full load and +40 ° C | Lifetime at 230 V ac, full load and +40 ° C | MTBF (IEC 61709) 230 V ac, max load, 40 ° C | Width | Depth | Weight | Approvals | Hold time at 120 V ac, typical full load | Hold time at 230 V ac, typical full load | Clamp type | Ripple max | Power consumption 120 V ac | Power consumption 230 V ac | Power drop from +60 °C to + 70 °C | Temperature min without derating | Type Power Supply | Conformal coated | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Redundant PSU 100-240 V AC/24 V DC, 10 A
Art:
CP10.241-R1
Copied
|
110-150 V
|
180 V DC
|
6 A
|
9 A
|
0,97
|
10 A
|
240 W
|
93 %
|
93,9 %
|
94,7 %
|
78000 h
|
109000 h
|
641000 h
|
39 mm
|
117 mm
|
0,6 kg
|
ATEX, CE, CSA US, cULus, IECEx
|
37 ms
|
37 ms
|
Spring-clamp
|
50 mV pp
|
2,17 A
|
1,14 A
|
6 W/°C
|
-25 °C
|
|
|
| ||
Redundant PSU, 100-240 V AC/24 V DC, 10 A Hot Swap
Art:
CP10.241-R2
Copied
|
110-150 V
|
180 V DC
|
6 A
|
9 A
|
0,97
|
10 A
|
240 W
|
93 %
|
93,9 %
|
94,7 %
|
78000 h
|
109000 h
|
641000 h
|
39 mm
|
117 mm
|
0,6 kg
|
ATEX, CE, CSA US, cULus, IECEx
|
37 ms
|
37 ms
|
Hot-swap
|
50 mV pp
|
2,17 A
|
1,14 A
|
6 W/°C
|
-25 °C
|
Redundant
|
|
| ||
Redundant PSU 100-240 VAC/110-300 VDC, 24-28 VDC, 10A
Art:
CP10.242-R2
Copied
|
110-300 V
|
360 V DC
|
6 A
|
9 A
|
0,97
|
10 A
|
240 W
|
93 %
|
93,9 %
|
94,7 %
|
78000 h
|
109000 h
|
641000 h
|
39 mm
|
117 mm
|
0,6 kg
|
CB, CE, cULus
|
37 ms
|
37 ms
|
Hot-swap
|
50 mV pp
|
2,17 A
|
1,14 A
|
6 W/°C
|
-25 °C
|
|
|
| ||
Redundant PSU 100-240 V AC/24 V DC, 20 A
Art:
CP20.241-R1
Copied
|
110-150 V
|
180 V DC
|
10 A
|
4,5 A
|
0,98
|
20 A
|
480 W
|
93,8 %
|
94,6 %
|
95,2 %
|
53000 h
|
90000 h
|
543000 h
|
48 mm
|
127 mm
|
0,83 kg
|
ATEX, CB, CE, CSA US, cRUus, cULus, IECEx
|
32 ms
|
32 ms
|
Spring-clamp
|
100 mV pp
|
4,28 A
|
2,25 A
|
12 W/°C
|
-40 °C
|
|
|
| ||
Redundant PSU 100-240V ac I/P 24V dc 20A 480W O/P
Art:
CP20.241-R2
Copied
|
110-150 V
|
180 V DC
|
10 A
|
4,5 A
|
0,98
|
20 A
|
480 W
|
93,8 %
|
94,6 %
|
95,2 %
|
53000 h
|
90000 h
|
543000 h
|
48 mm
|
127 mm
|
0,85 kg
|
ATEX, CB, CE, cRUus, cULus, IECEx
|
32 ms
|
32 ms
|
Hot-swap
|
100 mV pp
|
4,28 A
|
2,25 A
|
12 W/°C
|
-40 °C
|
Redundant
|
|
| ||
Redundant PSU, 100-240 V AC/24 V DC, 10 A Hot Swap Conf Coat
Art:
CP20.241-R2-C1
Copied
|
110-150 V
|
180 V DC
|
10 A
|
4,5 A
|
0,98
|
20 A
|
480 W
|
93,8 %
|
94,6 %
|
95,2 %
|
53000 h
|
90000 h
|
543000 h
|
48 mm
|
127 mm
|
0,85 kg
|
ATEX, CB, CE, cRUus, cULus, IECEx
|
32 ms
|
32 ms
|
Hot-swap
|
100 mV pp
|
4,28 A
|
2,25 A
|
12 W/°C
|
-40 °C
|
|
Yes
|
| ||
Redundant PSU 100-240 VAC/110-300 VDC, 24-28 VDC, 20A
Art:
CP20.242-R2
Copied
|
110-300 V
|
360 V DC
|
10 A
|
4,5 A
|
0,98
|
20 A
|
480 W
|
93,8 %
|
94,6 %
|
95,2 %
|
53000 h
|
90000 h
|
543000 h
|
48 mm
|
127 mm
|
0,85 kg
|
CB, CE, cULus
|
32 ms
|
32 ms
|
Hot-swap
|
100 mV pp
|
4,28 A
|
2,25 A
|
12 W/°C
|
-40 °C
|
|
|
|
Select a variant in the list