CONTA-CLIP

MFR Timed interface relay with fused base

MFR

  • Multifunction timing relay
  • 12V or 24V control
  • Screw or push-in base

Selected variant

Available in several variants

Selected variant

Technical data

Input Data

Holding voltage 0,6 Un ac/dc
Release voltage 0,1 Un
Input power rating 0,2
Power ac/dc 12 V
Overvoltage category III
Contamination degree 3
LED status Yes
Control contact terminals A1-B1
Control pulse length min 50 ms
Nominal frequency min 50 Hz
Number of functions 4
Rated frequency max 60 Hz

Output Data

Contact material AgNi
Switching voltage max 400 V ac
Rated contact voltage 250V ac
Switching capacity max 1500 VA
Contact load min 500 mW
Continuous current max / Inrush current max 6 / 10 A

Connection Data

Cross section single wire from 0,2 mm²
Cross section single wire to 2,5 mm²
Stripping length 10 mm
Torque 0,5 Nm

*Invisible Heading*

Connection type Screw
Recovery time <50 ms
Relay contact 1 CO
Repeatability accuracy ± 1%

General Data

Approvals CE
Time range 0,1 s - 6 h
Tolerance (0,8 - 1,1) Un
Setting accuracy ± 5%
IP class IP20
Operating temperature from -40 °C
Operating temperature to 50 °C
Electrical life in hours (AC1) 60x10³
Mechanical life hours 10x10⁶

Dimensions & Materials

Width 6,2 mm
Length 94,3 mm
Height TS 35 / 7.5 with base 95,4 mm

Additional Data

Tariff code 85364900
Country of origin EEC
Weight 43 g
Pack size 10

Accessories

Related

contaclip kds sr90
Product news

Every angle covered with 90 degree cable entry system

Engineers and technicians are seeking solutions that streamline assembly whilst maintaining high levels of protection and flexibility. KDS-SR90 angled screw frames and inlays bring a new level of efficiency to cable routing with a unique 90° entry design.

crouzet millenium slim on limited time discount
Product news

The smallest logic controller ever on limited time discount

The smallest logic controller by Crouzet is now 20% off for a limited time only! A powerhouse packed into just 17.5mm! Efficiency, adaptability, and seamless integration with free software.

11 questions to get the right signalling device with Auer Signal & OEM Automatic
Blog

11 questions to get the right signalling device – a whitepaper

Do you require signalling devices and beacons in your production process? Download our latest whitepaper!

bespoke solutions electricity meter control boxes
Case studies

Control Box Assembly for Industrial Electricity Metering - A case study

Here, our customer requires control boxes for electricity metering systems. We leveraged our expertise to deliver easy-to-install, ready-to-use assemblies. We look forward to creating more of these bespoke control boxes for our customer.

DC circuit protection PISA M and circuit breakers
Blog

Safeguard systems with DC circuit protection

This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.

IATECH, the industrial automation technology exhibition OEM automatic
Company news

Recap of IATECH

Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.

Parts Holding voltage Release voltage Input power rating Power ac/dc Nominal frequency min Rated frequency max Contact material Switching voltage max Rated contact voltage Switching capacity max Contact load min Continuous current max / Inrush current max Stripping length Torque Connection type Recovery time Repeatability accuracy Tolerance Setting accuracy Electrical life in hours (AC1) Mechanical life hours Tariff code Weight Price
0,6 Un ac/dc
0,1 Un
0,2
12 V
50 Hz
60 Hz
AgNi
400 V ac
250V ac
1500 VA
500 mW
6 / 10 A
10 mm
0,5 Nm
Screw
<50 ms
± 1%
(0,8 - 1,1) Un
± 5%
60x10³
10x10⁶
85364900
43 g
0,6 Un ac/dc
0,1 Un
0,3
24 V
50 Hz
60 Hz
AgNi
400 V ac
250V ac
1500 VA
500 mW
6 / 10 A
10 mm
0,5 Nm
Screw
<50 ms
± 1%
(0,8 - 1,1) Un
± 5%
60x10³
10x10⁶
85364900
43 g
0,6 Un ac/dc
0,1 Un
0,2
12 V
50 Hz
60 Hz
AgNi
400 V ac
250V ac
1500 VA
500 mW
6 / 10 A
8 mm
Push-in
<50 ms
± 1%
(0,8 - 1,1) Un
± 5%
60x10³
10x10⁶
85364900
37,9 g
0,6 Un ac/dc
0,1 Un
0,3
24 V
50 Hz
60 Hz
AgNi
400 V ac
250V ac
1500 VA
500 mW
6 / 10 A
8 mm
Push-in
<50 ms
(0,8 - 1,1) Un
60x10³
10x10⁶
85364900
21,5 g
12 - 24 V
10 mm
0,5 Nm
Screw
± 1%
± 5%
85369010
38 g
12 - 24 V
8 mm
Push-in
± 1%
± 5%
85369010
33 g

Selected variant

Select a variant in the list

Contact us
If you need any help, you can contact us in one of the following ways:
0116 284 9900
Send e-mail
Use live chat
Do you need help?
Logo

Cookie settings for OEM.CO.UK

Cookies help us improve your experience with us, so in order to be able to handle login information, offer you personalised content and for basic functionality of this website, we use some cookies.

We will never sell on any information about you. 

You can accept all cookies or personalise your cookies preferences, you can also change your cookie preferences at any time by visiting our contact page.

Necessary Cookies

These cookies are necessary for the website to work and can not be turned off in our systems. They are usually used only in response to actions you have taken in connection with a service request, for example when setting personal preferences, logging in or filling out a form.

Analysis and measurement cookies

These cookies allow us to count the number of visits and traffic sources so that we can measure and improve our website performance. They help us know which pages are more or less popular and how visitors navigate around the site. The information that these cookies collect is aggregated and therefore completely anonymous. If you do not allow these cookies, we do not know when you have visited our website.

Marketing cookies

These cookies can be added by our partners. They can use them to create a profile of you, based on your interests, to show you more relevant information. They do not store any personal information - only information about your browser and device. If you do not accept these cookies, you will have a more general and less customized user experience.