CONTA-CLIP

Relay modules only

  • Narrow 5 mm width
  • Sensitice DC coil, 170 mW
  • Secure isolation, VDE 0160/EN 50178
  • 6 mm clearance and creepage distance
  • Protection class II, VDE 0631/EN 60730

Selected variant

Available in several variants

Selected variant

Technical data

Input Data

Holding voltage 0,4 Un dc
Operating voltage 3,5-7,5 V dc
Input power rating 0,17
Coil voltage 5 V dc
Coil resistance 147 Ω
Release voltage 0,05 Un
Overvoltage category III

Output Data

Contact configuration 1 CO
Response / release time 12 / 5 ms
Bounce time at close of the NO/NC contact 3/8 ms
Rated V ac / switching V ac max 250 / 400 V ac
Continuous current max / Inrush current max 6 / 10 A
Contact material AgNi
Contact load min 500 mW
Switching capacity max 1500 VA

General Data

Electrical life in hours (AC1) 60x10³
Operating temperature from -40 °C
Operating temperature to 85 °C
Mechanical life hours 10x10⁶
Approvals CE

Dimensions & Materials

Length 28 mm
Width 5 mm
Protection RTIII (wash tight)
Height 15 mm

Additional Data

Pack size 10  
Country of origin IT
Tariff code 85364900
Weight 5 g

Accessories

Related

contaclip kds sr90
Product news

Every angle covered with 90 degree cable entry system

Engineers and technicians are seeking solutions that streamline assembly whilst maintaining high levels of protection and flexibility. KDS-SR90 angled screw frames and inlays bring a new level of efficiency to cable routing with a unique 90° entry design.

crouzet millenium slim on limited time discount
Product news

The smallest logic controller ever on limited time discount

The smallest logic controller by Crouzet is now 20% off for a limited time only! A powerhouse packed into just 17.5mm! Efficiency, adaptability, and seamless integration with free software.

11 questions to get the right signalling device with Auer Signal & OEM Automatic
Blog

11 questions to get the right signalling device – a whitepaper

Do you require signalling devices and beacons in your production process? Download our latest whitepaper!

bespoke solutions electricity meter control boxes
Case studies

Control Box Assembly for Industrial Electricity Metering - A case study

Here, our customer requires control boxes for electricity metering systems. We leveraged our expertise to deliver easy-to-install, ready-to-use assemblies. We look forward to creating more of these bespoke control boxes for our customer.

DC circuit protection PISA M and circuit breakers
Blog

Safeguard systems with DC circuit protection

This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.

IATECH, the industrial automation technology exhibition OEM automatic
Company news

Recap of IATECH

Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.

Parts Holding voltage Operating voltage Input power rating Output voltage range Coil voltage Control current Coil resistance Number of channels Operating range Release voltage Overvoltage category Input voltage Contact configuration Response / release time Bounce time at close of the NO/NC contact Rated V ac / switching V ac max Continuous current max / Inrush current max Contact material Contact load min Switching capacity max Switching current min Voltage drop at 20 °C and rated current max Residual current at 55 °C max Electrical life in hours (AC1) Operating temperature from Operating temperature to Mechanical life hours Approvals Test voltage eff Protection Country of origin Tariff code Weight Price
0,4 Un dc
3,5-7,5 V dc
0,17
5 V dc
147 Ω
0,05 Un
III
1 CO
12 / 5 ms
3/8 ms
250 / 400 V ac
6 / 10 A
AgNi
500 mW
1500 VA
60x10³
-40 °C
85 °C
10x10⁶
CE
RTIII (wash tight)
IT
85364900
5 g
0,4 Un dc
8,4-18 V dc
0,17
12 V dc
848 Ω
0,05 Un
III
1 CO
12 / 5 ms
3/8 ms
250 / 400 V ac
6 / 10 A
AgNi
500 mW
1500 VA
60x10³
-40 °C
85 °C
10x10⁶
CE
RTIII (wash tight)
IT
85364900
4,9 g
0,4 Un dc
16,8-36 V dc
0,17
24 V dc
3390 Ω
0,05 Un
III
1 CO
12 / 5 ms
3/8 ms
250 / 400 V ac
6 / 10 A
AgNi
500 mW
1500 VA
60x10³
-40 °C
85 °C
10x10⁶
CE
RTIII (wash tight)
EEC
85364900
5 g
0,4 Un dc
42-90 V dc
0,176 W
60 V dc
20500 Ω
0,05 Un
III
1 CO
12 / 5 ms
3/8 ms
250 / 400 V ac
6 / 10 A
AgNi
500 mW
1500 VA
60x10³
-40 °C
85 °C
10x10⁶
CE
RTIII (wash tight)
IT
85364900
5 g
0,4 Un dc
3,5-7,5 V dc
0,17
5 V dc
147 Ω
0,05 Un dc
III
1 CO
12 / 5 ms
3/8 ms
250 / 400 V ac
6 / 10 A
AgNi + Au
50 mW
1500 VA
60x10³
-40 °C
85 °C
10x10⁶
CE
RTIII (wash tight)
IT
85364900
5,2 g
0,4 Un dc
8,4-18 V dc
0,17
12 V dc
848 Ω
0,05 Un dc
III
1 CO
12 / 5 ms
3/8 ms
250 / 400 V ac
6 / 10 A
AgNi + Au
50 mW
1500 VA
60x10³
-40 °C
85 °C
10x10⁶
CE
RTIII (wash tight)
IT
85364900
5,2 g
0,4 Un dc
16,8-36 V dc
0,17
24 V dc
3390 Ω
0,05 Un dc
III
1 CO
12 / 5 ms
3/8 ms
250 / 400 V ac
6 / 10 A
AgNi + Au
50 mW
1500 VA
60x10³
-40 °C
85 °C
10x10⁶
CE
RTIII (wash tight)
EEC
85364900
5,2 g
0,4 Un dc
33,6-72 V dc
0,217
48 V dc
10600 Ω
0,05 Un dc
III
1 CO
12 / 5 ms
3/8 ms
250 / 400 V ac
6 / 10 A
AgNi + Au
50 mW
1500 VA
60x10³
-40 °C
85 °C
10x10⁶
CE
RTIII (wash tight)
IT
85364900
5,2 g
0,4 Un dc
42-90 V dc
0,176 W
60 V dc
20500 Ω
0,05 Un dc
III
1 CO
12 / 5 ms
3/8 ms
250 / 400 V ac
6 / 10 A
AgNi + Au
50 mW
1500 VA
60x10³
-40 °C
85 °C
10x10⁶
CE
RTIII (wash tight)
IT
85364900
5,2 g
0.085
1,5…33V dc
7 mA
1
8-17 V dc
4 V dc
12 V dc
0,02 / 0,2 ms
6 / 50 A
0,001 A
0,4 V dc
0,001 mA
-20 °C
55 °C
4 kV
IT
85364190
3,6 g
0,17
12…240 V ac
7 mA
1
16-30 V dc
4 V dc
24 V dc
12 / 12 ms
2 / 40 A
0,022 A
1,6 V ac
1,5 mA
-20 °C
55 °C
2,5 kV
IT
85364900
3,6 g
0,17
1,5…24 V dc
7,2 mA
1
16-30 V dc
10 V dc
24 V dc
0,1 / 0,6 ms
2 / 40 A
0,001 A
0,12 V dc
0,001 mA
-20 °C
55 °C
2,5 kV
IT
85364900
3,6 g
0,18
12…240 V ac
3 mA
1
35-72 V dc
20 V dc
60 V dc
12 / 12 ms
2 / 40 A
0,022 A
1,6 V ac
1,5 mA
-20 °C
55 °C
2,5 kV
IT
85364900
3,8 g
0,18
1,5…24 V dc
3 mA
1
35-72 V dc
20 V dc
60 V dc
0,04 / 0,6 ms
2 / 40 A
0,001 A
0,12 V dc
0,001 mA
-20 °C
55 °C
2,5 kV
IT
85364900
3,6 g

Selected variant

Select a variant in the list

Contact us
If you need any help, you can contact us in one of the following ways:
0116 284 9900
Send e-mail
Use live chat
Do you need help?
Logo

Cookie settings for OEM.CO.UK

Cookies help us improve your experience with us, so in order to be able to handle login information, offer you personalised content and for basic functionality of this website, we use some cookies.

We will never sell on any information about you. 

You can accept all cookies or personalise your cookies preferences, you can also change your cookie preferences at any time by visiting our contact page.

Necessary Cookies

These cookies are necessary for the website to work and can not be turned off in our systems. They are usually used only in response to actions you have taken in connection with a service request, for example when setting personal preferences, logging in or filling out a form.

Analysis and measurement cookies

These cookies allow us to count the number of visits and traffic sources so that we can measure and improve our website performance. They help us know which pages are more or less popular and how visitors navigate around the site. The information that these cookies collect is aggregated and therefore completely anonymous. If you do not allow these cookies, we do not know when you have visited our website.

Marketing cookies

These cookies can be added by our partners. They can use them to create a profile of you, based on your interests, to show you more relevant information. They do not store any personal information - only information about your browser and device. If you do not accept these cookies, you will have a more general and less customized user experience.