COMATRELECO

Relay and Push-In Socket Sets

The most common relays bought by the majority of customers are now available as a relay and socket set, simplifying procurement with only 1 part number for the set. Relays available in 24V DC and 230V AC. The sets save time during assembly and wiring and use the latest push-in sockets from ComatReleco saving 25% more space in your panel.

Read more
  • Includes the slimmest sockets on the market
  • One part number including the relay and socket
  • Saves time during assembly and wiring
  • The most common relays available as a set

Selected variant

Selected variant

Technical data

Approvals CE, Gost R, RoHS, CCC, CSA, Lloyd´s, UL
Bounce time 3
Breaking capacity current 10 A
Breaking Voltage 250 V
Coil voltage dc 24 V DC
Contact material AgNI
Frequency 50 Hz
Insulation class EN60947 250 V Pollution 3, Group C
IP class IP40
Isolation contact/coil 2500 V
Isolation contact/contact 2500 V
Mechanical life expectancy AC: 10 Mill./DC: 20 Mill
Nominal power dc 1 W
Number of contacts 2
Optional coil DX (diode + LED)
Recommended max load 10 A/250 V AC-1; 0,5 A/110 V DC-1
Recommended min load 10 mA/10 V
Release time 8 ms
Release time + contact debounce 9 ms
Resistive load 110 V dc max 55 W
Resistive load 24 V dc max 240 W
Response time 16 ms
Storage temperature max 80 °C
Storage temperature min -40 °C
Surge current (20 ms) 30 A
Temperature operational max 60 °C
Temperature operational min -40 °C
Tripping voltage max UN 0,2
Weight 43 g
Working Un 0,8-1,10

Product description

The most common relays bought by the majority of customers are now available as a relay and socket set, simplifying procurement with only 1 part number for the set. Relays available in 24V DC and 230V AC. The sets save time during assembly and wiring and use the latest push-in sockets from ComatReleco saving 25% more space in your panel.

Accessories

Related

IATECH, the industrial automation technology exhibition OEM automatic
Company news

Recap of IATECH

Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.

zoller and frohlich cable preparation machines
Product news Blog

Book your Cable Preparation Machinery Demo at OEM

To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.

IATECH industrial automation components exhibition in at leicester marriott hotel by OEM Automatic
Company news

OEM introduces IATECH - The Industrial Automation Technology Expo

We are thrilled to announce the launch of IATECH, THe Industrial Automation Technology expo at Leicester Marriott Hotel on 23rd October. The ultimate platform for showcasing our extensive product range and broad business areas, featuring over 50 leading suppliers under one roof!

automation components for specialist vehicles
Blog

Automation Components for Specialist Vehicles

The specialist vehicle industry can include automotive and EV, heavy vehicles such as agriculture and rail, and marine.  This email takes you through some of the various products we offer for specialist vehicle applications.

Wohner power distribution
Product news Blog

Modern Power Distribution

This blog post delves into the key components, current trends, and best practices in power distribution, illustrating the significant impact these systems have on our daily operations and long-term energy strategies.

Dehn lightning and surge protection
Product news Blog

Lightning and surge protection to safeguard equipment

We shine a spotlight on surge protection devices (SPDs), a crucial yet often overlooked component in industrial settings. Every surge of electricity, every fluctuation in voltage, poses a potential threat to your machinery and systems.

Parts Approvals Bounce time Breaking capacity current Coil voltage ac Coil voltage dc Contact material Insulation class EN60947 Isolation contact/coil Isolation contact/contact Mechanical life expectancy Nominal power ac Nominal power dc Number of contacts Optional coil Overvoltage UNX max Recommended max load Recommended min load Release time Release time + contact debounce Resistive load 110 V dc max Resistive load 24 V dc max Response time Storage temperature max Storage temperature min Surge current (20 ms) Temperature operational max Temperature operational min Tripping voltage max UN Type of relay Weight Voltage min Working Un Price
CE, Gost R, RoHS, CCC, CSA, Lloyd´s, UL
3
10 A
24 V DC
AgNI
250 V Pollution 3, Group C
2500 V
2500 V
AC: 10 Mill./DC: 20 Mill
1 W
2
DX (diode + LED)
10 A/250 V AC-1; 0,5 A/110 V DC-1
10 mA/10 V
8 ms
9 ms
55 W
240 W
16 ms
80 °C
-40 °C
30 A
60 °C
-40 °C
0,2
43 g
0,8-1,10
CE, Gost R, RoHS, CCC, CSA, Lloyd´s, UL
3
10 A
230 V AC
AgNI
250 V Pollution 3, Group C
2500 V
2500 V
AC: 10 Mill./DC: 20 Mill
1,2 VA
2
X (LED)
10 A/250 V AC-1; 0,5 A/110 V DC-1
10 mA/10 V
8 ms
9 ms
55 W
240 W
16 ms
80 °C
-40 °C
30 A
60 °C
-40 °C
0,25
43 g
0,8-1,10
CE, Gost R, RoHS, CCC, CSA, Lloyd´s, UL
5 A
24 V DC
AgNi + 0,2 µ Au
2000 V
2500 V
AC: 10 Mill./DC: 20 Mill
1 W
4
DX (diode + LED)
5 A/250V AC-1; 5 A/30 V DC-1
10 mA/10 V
6 ms
7 ms
50 W
100 W
80 °C
-40 °C
15 A
60 °C
-40 °C
0,25
43 g
0,8-1,1
CE, Gost R, RoHS, CCC, CSA, Lloyd´s, UL
5 A
230 V AC
AgNi + 0,2 µ Au
2000 V
2500 V
AC: 10 Mill./DC: 20 Mill
1,2 VA
4
X (LED)
5 A/250V AC-1; 5 A/30 V DC-1
10 mA/10 V
6 ms
7 ms
50 W
100 W
80 °C
-40 °C
15 A
60 °C
-40 °C
0,25
43 g
0,8-1,1
CCC, CE, CSA, Gost R, RoHS, UL
10 A
230 V AC
AgNI
250 V (pollution 3, Group C)
AC:10 Mill./DC:20 Mill
1,1 VA
1
X (LED)
1,1
10 mA / 10 V
5 ms
8 ms
80 °C
-40 °C
30 A
70 °C
-40 °C
0,1
Industrial relay
CCC, CE, CSA, Gost R, RoHS, UL
10 A
24 V DC
AgNI
250 V (pollution 3, Group C)
AC:10 Mill./DC:20 Mill
0,7 W
1
X (LED)
1,1
10 mA / 10 V
5 ms
8 ms
80 °C
-40 °C
30 A
70 °C
-40 °C
0,1
Industrial relay
1
5 A
230 V AC
AgNi + 0,2 µ Au
5000 V
3000 V
AC: 10Mill/. DC: 20 Mill
1,1 VA
2
X (LED)
1,1
5 A/250 V AC 1; 0,5A/110 V DC-1
10 mA/10 V
5 ms
8 ms
10 ms
15 A
21 g
0,6 V
0,8-1,10
1
5 A
24 V DC
AgNi + 0,2 µ Au
5000 V
3000 V
AC: 10Mill/. DC: 20 Mill
0,7 W
2
X (LED)
1,1
5 A/250 V AC 1; 0,5A/110 V DC-1
10 mA/10 V
5 ms
8 ms
10 ms
15 A
21 g
0,35 V
0,8-1,10

Selected variant

Select a variant in the list

Contact us
If you need any help, you can contact us in one of the following ways:
0116 284 9900
Send e-mail
Use live chat
Do you need help?
Logo

Cookie settings for OEM.CO.UK

Cookies help us improve your experience with us, so in order to be able to handle login information, offer you personalised content and for basic functionality of this website, we use some cookies.

We will never sell on any information about you. 

You can accept all cookies or personalise your cookies preferences, you can also change your cookie preferences at any time by visiting our contact page.

Necessary Cookies

These cookies are necessary for the website to work and can not be turned off in our systems. They are usually used only in response to actions you have taken in connection with a service request, for example when setting personal preferences, logging in or filling out a form.

Analysis and measurement cookies

These cookies allow us to count the number of visits and traffic sources so that we can measure and improve our website performance. They help us know which pages are more or less popular and how visitors navigate around the site. The information that these cookies collect is aggregated and therefore completely anonymous. If you do not allow these cookies, we do not know when you have visited our website.

Marketing cookies

These cookies can be added by our partners. They can use them to create a profile of you, based on your interests, to show you more relevant information. They do not store any personal information - only information about your browser and device. If you do not accept these cookies, you will have a more general and less customized user experience.