DELCON
The relays are used as an interface between control systems and ac loads. The relays can handle inductive loads without load current reduction, which makes them very suitable for connection to, for example, solenoid valves and contactors. The relays have no mechanical parts, which means very reliable application. The integrated interference protection provides reliable operation even in very demanding electrical environments. Thanks to interference protection, signal cables can be run alongside power cables on, for example, cable racks for more than 1.5 km without capacitive cross-talk affecting relays. The SLOP models are especially designed for connection to 2-wire sensors that produce leakage current. The relays are blind to leakage currents up to 3.0 mA. For forward/reverse control of ac motors, the SLO24TRA is used. The relay has a higher operating voltage and withstands regenerated voltages from motors.
Input data |
|
---|---|
Input current at nominal voltage, typ | 15 mA |
Input current at nominal voltage, max | 17 mA |
Response time | 0,5 ms |
Release time | 11 ms |
Switching voltage | 2,7 V |
Turn-off voltage | 2,5 V |
Input impedance, typ | 0,3 kΩ |
Input voltage nom | 5 |
Output data |
|
Number of poles | 1 |
Load current ac max | 3 A |
Leakage current | 1,5 mA |
Peak current | 90 A (20ms) A |
*Invisible Heading* |
|
---|---|
Load voltage ac max | 265 V |
Voltage drop | 1 V |
General data |
|
Width | 12,5 mm |
Temperature operational min | -10 °C |
Temperature operational max | 70 °C |
Storage temperature min | -40 °C |
Storage temperature max | 70 °C |
Material | PBT |
Weight | 40 g |
Approvals | CE, UL |
The relays are used as an interface between control systems and ac loads. The relays can handle inductive loads without load current reduction, which makes them very suitable for connection to, for example, solenoid valves and contactors. The relays have no mechanical parts, which means very reliable application. The integrated interference protection provides reliable operation even in very demanding electrical environments. Thanks to interference protection, signal cables can be run alongside power cables on, for example, cable racks for more than 1.5 km without capacitive cross-talk affecting relays. The SLOP models are especially designed for connection to 2-wire sensors that produce leakage current. The relays are blind to leakage currents up to 3.0 mA. For forward/reverse control of ac motors, the SLO24TRA is used. The relay has a higher operating voltage and withstands regenerated voltages from motors.
Engineers and technicians are seeking solutions that streamline assembly whilst maintaining high levels of protection and flexibility. KDS-SR90 angled screw frames and inlays bring a new level of efficiency to cable routing with a unique 90° entry design.
The smallest logic controller by Crouzet is now 20% off for a limited time only! A powerhouse packed into just 17.5mm! Efficiency, adaptability, and seamless integration with free software.
Do you require signalling devices and beacons in your production process? Download our latest whitepaper!
Here, our customer requires control boxes for electricity metering systems. We leveraged our expertise to deliver easy-to-install, ready-to-use assemblies. We look forward to creating more of these bespoke control boxes for our customer.
This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Input current at nominal voltage, typ | Input current max | Input current at nominal voltage, max | Response time | Release time | Switching voltage | Turn-off voltage | Input impedance, typ | Input voltage nom | Load current ac max | Leakage current | Peak current | Load voltage ac max | Load voltage dc max | Voltage drop | Temperature operational min | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]()
O/P Plug-in Relay 5V dc / 0-240V ac 3A
Art:
SLO5TR
Copied
|
15 mA
|
|
17 mA
|
0,5 ms
|
11 ms
|
2,7 V
|
2,5 V
|
0,3 kΩ
|
5
|
3 A
|
1,5 mA
|
90 A (20ms) A
|
265 V
|
|
1 V
|
-10 °C
|
| ||
![]()
O/P Plug-in Relay 12V dc / 0-240V ac 3A
Art:
SLO12TR
Copied
|
12 mA
|
|
15 mA
|
0,5 ms
|
11 ms
|
8 V
|
7 V
|
1 kΩ
|
12
|
3 A
|
1,5 mA
|
90 A (20ms) A
|
265 V
|
|
1 V
|
-10 °C
|
| ||
![]()
O/P Plug-in Relay 24V dc / 0-240V ac 3A
Art:
SLO24TR
Copied
|
15 mA
|
|
17 mA
|
0,5 ms
|
11 ms
|
16 V
|
14 V
|
1,4 kΩ
|
24
|
3 A
|
50 µA
|
90 A (20ms) A
|
265 V
|
|
1 V
|
-10 °C
|
| ||
![]()
O/P Plug-in Relay 24V dc / 0-240V ac 2.5A Motor Loads
Art:
SLO24TRA
Copied
|
15 mA
|
|
17 mA
|
0,5 ms
|
11 ms
|
16 V
|
14 V
|
1,4 kΩ
|
24
|
2,5 A
|
50 µA
|
60 A (20ms) A
|
460 V
|
|
1 V
|
-10 °C
|
| ||
![]()
O/P Plug-in Relay 24V dc / 0-240/250V ac/dc 1.2A
Art:
SLO24IRA
Copied
|
15 mA
|
|
17 mA
|
0,5 ms
|
11 ms
|
16 V
|
14 V
|
1,4 kΩ
|
24
|
3 A
|
50 µA
|
90 A (20ms) A
|
265 V
|
300 V
|
1 V
|
-10 °C
|
| ||
![]()
O/P Plug-in Relay 120V ac / 0-240V ac 3A
Art:
SLOP120TR
Copied
|
5 mA
|
6 mA
|
|
10 ms
|
20 ms
|
80 V
|
65 V
|
24 kΩ
|
120
|
3 A
|
1,5 mA
|
90 A (20ms) A
|
265 V
|
|
1 V
|
-25 °C
|
| ||
![]()
O/P Plug-in Relay 230V ac / 0-240V ac 1 A
Art:
SLOA230TR
Copied
|
5 mA
|
6 mA
|
|
50 ms
|
50 ms
|
170 V
|
110 V
|
46 kΩ
|
230
|
1 A
|
1,5 mA
|
90 A (20ms) A
|
265 V
|
|
1,5 V
|
-25 °C
|
| ||
![]()
O/P Plug-in Relay 230V ac / 0-240V ac 1.5A
Art:
SLOP230TR
Copied
|
5 mA
|
6 mA
|
|
10 ms
|
20 ms
|
170 V
|
110 V
|
46 kΩ
|
230
|
1,5 A
|
1,5 mA
|
90 A (20ms) A
|
265 V
|
|
1,5 V
|
-25 °C
|
|
Select a variant in the list