KATKO
Katko 16-40A switch disconnectors are available with either DIN-rail or screw mounting (KU) and door mounting (RT).
3-pole and 4-pole KU-switches as standard. Other configurations on request.
Â
Switch technology by means of silver contacts ensures safe and durable operation.
Compatible (KU & RT) with handles LKX50, LKX50YR, LK10 and LK10YR.
Compatible (KU) with LXXXAD11 shafts (XXX is length of the shaft in millimetres)
Â
Door mounted versions come with integrated 42mm aluminium shaft with AD11 adapter. Handle is required for door mounting installation. When using any other handle than LKX50, LKX50YR, LK10RT or LK10RTYR you will also need a special counter nut for the handle (RT COUNTER NUT).
KU switch will be delivered with black direct handle. KU switches can also be used with external shaft and handle.
Â
Tested according to IEC 60947-3.
General Data |
|
---|---|
Number of poles | 3 |
Rated insulation voltage Ui | 800 V |
Rated thermal current, Ith | 25 A |
Type | Screw-mounted |
Terminals / Bolt size Cu | 1.5-16 |
Nominal values with cable size | 4 |
Weight | 0,12 kg |
Rated operational current, Ie |
|
Operational current - AC-21A - 400/415V | 25 A |
Operational current - AC-21A - 500V | 25 A |
Operational current - AC-21A - 690V | 25 A |
Operational current - AC-22A - 400/415V | 16 A |
Operational current - AC-22A - 500V | 16 A |
Operational current - AC-22A - 690V | 16 A |
Operational current - AC-23A - 400/415V | 16 A |
Operational current - AC-23A - 500V | 16 A |
Operational current - AC-23A - 690V | 16 A |
Rated operational power for 3-phase (1500 r.p.m.) squirrel cage induction motors (kW) |
|
Operational power - AC-23A - 400/415V | 7,5 kW |
*Invisible Heading* |
|
---|---|
Operational power - AC-23A - 500V | 7,5 kW |
Operational power - AC-23A - 690V | 11 kW |
Rated fused short circuit current |
|
Back-up fuse | 25 A |
R.M.S value, IK | 50 kA |
Peak value | 3,8 kA |
Rated impulse withstand voltage Uimp | 8 kV |
Rated short circuit making capacity at 690V, lcm | 1 kA |
Rated short time withstand current at 690V (1 s), lcw | 0.7 kA |
Rated breaking capacity, Icn |
|
Breaking capacity - AC-23A - 400/415V | 128 A |
Breaking capacity - AC-23A - 500V | 128 A |
Breaking capacity - AC-23A - 690V | 128 A |
Additional Details |
|
Electrical endurance | 3000 operations |
Mechanical endurance | 50000 operations |
Max terminal torque | 1.8 Nm |
Tariff code | 85365080 |
Country of origin | FI |
Katko 16-40A switch disconnectors are available with either DIN-rail or screw mounting (KU) and door mounting (RT).
3-pole and 4-pole KU-switches as standard. Other configurations on request.
Â
Switch technology by means of silver contacts ensures safe and durable operation.
Compatible (KU & RT) with handles LKX50, LKX50YR, LK10 and LK10YR.
Compatible (KU) with LXXXAD11 shafts (XXX is length of the shaft in millimetres)
Â
Door mounted versions come with integrated 42mm aluminium shaft with AD11 adapter. Handle is required for door mounting installation. When using any other handle than LKX50, LKX50YR, LK10RT or LK10RTYR you will also need a special counter nut for the handle (RT COUNTER NUT).
KU switch will be delivered with black direct handle. KU switches can also be used with external shaft and handle.
Â
Tested according to IEC 60947-3.
This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.
We are thrilled to announce the launch of IATECH, THe Industrial Automation Technology expo at Leicester Marriott Hotel on 23rd October. The ultimate platform for showcasing our extensive product range and broad business areas, featuring over 50 leading suppliers under one roof!
The specialist vehicle industry can include automotive and EV, heavy vehicles such as agriculture and rail, and marine. This email takes you through some of the various products we offer for specialist vehicle applications.
This blog post delves into the key components, current trends, and best practices in power distribution, illustrating the significant impact these systems have on our daily operations and long-term energy strategies.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Number of poles | Rated thermal current, Ith | Type | Nominal values with cable size | Weight | Operational current - AC-21A - 400/415V | Operational current - AC-21A - 500V | Operational current - AC-21A - 690V | Operational current - AC-22A - 400/415V | Operational current - AC-22A - 500V | Operational current - AC-22A - 690V | Operational current - AC-23A - 400/415V | Operational current - AC-23A - 500V | Operational current - AC-23A - 690V | Operational power - AC-23A - 400/415V | Operational power - AC-23A - 500V | Operational power - AC-23A - 690V | Back-up fuse | R.M.S value, IK | Peak value | Rated impulse withstand voltage Uimp | Breaking capacity - AC-23A - 400/415V | Breaking capacity - AC-23A - 500V | Breaking capacity - AC-23A - 690V | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
KU 316, Screw Mounted, 3-pole, 16A
Art:
25769
Copied
|
3
|
25 A
|
Screw-mounted
|
4
|
0,12 kg
|
25 A
|
25 A
|
25 A
|
16 A
|
16 A
|
16 A
|
16 A
|
16 A
|
16 A
|
7,5 kW
|
7,5 kW
|
11 kW
|
25 A
|
50 kA
|
3,8 kA
|
8 kV
|
128 A
|
128 A
|
128 A
|
| ||
KU 325, Screw Mounted, 3-pole, 25A
Art:
25770
Copied
|
3
|
40 A
|
Screw-mounted
|
10
|
0,12 kg
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
11 kW
|
15 kW
|
22 kW
|
25 A
|
50 kA
|
3,8 kA
|
12 kV
|
200 A
|
200 A
|
200 A
|
| ||
KU 340, Screw Mounted, 3-pole, 40A
Art:
25771
Copied
|
3
|
63 A
|
Screw-mounted
|
16
|
0,12 kg
|
40 A
|
40 A
|
40 A
|
40 A
|
40 A
|
40 A
|
40 A
|
25 A
|
25 A
|
22 kW
|
15 kW
|
22 kW
|
40 A
|
25 kA
|
4,5 kA
|
8 kV
|
320 A
|
200 A
|
200 A
|
| ||
KU 416, Screw Mounted, 4-pole, 16A
Art:
25772
Copied
|
4
|
25 A
|
Screw-mounted
|
4
|
0,15 kg
|
25 A
|
25 A
|
25 A
|
16 A
|
16 A
|
16 A
|
16 A
|
16 A
|
16 A
|
7,5 kW
|
7,5 kW
|
11 kW
|
25 A
|
50 kA
|
3,8 kA
|
8 kV
|
128 A
|
128 A
|
128 A
|
| ||
KU 425, Screw Mounted, 4-pole, 25A
Art:
25773
Copied
|
4
|
40 A
|
Screw-mounted
|
10
|
0,15 kg
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
11 kW
|
15 kW
|
22 kW
|
25 A
|
50 kA
|
3,8 kA
|
8 kV
|
200 A
|
200 A
|
200 A
|
| ||
KU 440, Screw Mounted, 4-pole, 40A
Art:
25774
Copied
|
4
|
63 A
|
Screw-mounted
|
16
|
0,15 kg
|
40 A
|
40 A
|
40 A
|
40 A
|
40 A
|
40 A
|
40 A
|
25 A
|
25 A
|
22 kW
|
15 kW
|
22 kW
|
40 A
|
25 kA
|
4,5 kA
|
8 kV
|
320 A
|
200 A
|
200 A
|
| ||
RT 316 L42AD11, Door Mounted, 3-Pole, 16A
Art:
26128
Copied
|
3
|
25 A
|
Door-mounted
|
4
|
0,12 kg
|
25 A
|
25 A
|
25 A
|
16 A
|
16 A
|
16 A
|
16 A
|
16 A
|
16 A
|
7,5 kW
|
7,5 kW
|
11 kW
|
25 A
|
50 kA
|
3,8 kA
|
8 kV
|
128 A
|
128 A
|
128 A
|
| ||
RT 316 L42AD11LKX50, Door Mounted, 3-Pole, 16A with LKX50 handle
Art:
25775
Copied
|
3
|
25 A
|
Door-mounted
|
4
|
0,17 kg
|
25 A
|
25 A
|
25 A
|
16 A
|
16 A
|
16 A
|
16 A
|
16 A
|
16 A
|
7,5 kW
|
7,5 kW
|
11 kW
|
25 A
|
50 kA
|
3,8 kA
|
8 kV
|
128 A
|
128 A
|
128 A
|
| ||
RT 316 L42AD11LKX50YR, Door Mounted, 3-Pole, 16A with LKX50YR handle
Art:
25778
Copied
|
3
|
25 A
|
Door-mounted
|
4
|
0,17 kg
|
25 A
|
25 A
|
25 A
|
16 A
|
16 A
|
16 A
|
16 A
|
16 A
|
16 A
|
7,5 kW
|
7,5 kW
|
11 kW
|
25 A
|
50 kA
|
3,8 kA
|
8 kV
|
128 A
|
128 A
|
128 A
|
| ||
RT 325 L42AD11, Door Mounted, 3-Pole, 25A
Art:
26129
Copied
|
3
|
40 A
|
Door-mounted
|
10
|
0,12 kg
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
11 kW
|
15 kW
|
22 kW
|
25 A
|
50 kA
|
3,8 kA
|
8 kV
|
200 A
|
200 A
|
200 A
|
| ||
RT 325 L42AD11LKX50, Door Mounted, 3-Pole, 25A with LKX50 handle
Art:
25776
Copied
|
3
|
40 A
|
Door-mounted
|
10
|
0,17 kg
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
11 kW
|
15 kW
|
22 kW
|
25 A
|
50 kA
|
3,8 kA
|
8 kV
|
200 A
|
200 A
|
200 A
|
| ||
RT 325 L42AD11LKX50YR, Door Mounted, 3-Pole, 25A with LKX50YR handle
Art:
25779
Copied
|
3
|
40 A
|
Door-mounted
|
10
|
0,17 kg
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
25 A
|
11 kW
|
15 kW
|
22 kW
|
25 A
|
50 kA
|
3,8 kA
|
8 kV
|
200 A
|
200 A
|
200 A
|
| ||
RT 340 L42AD11, Door Mounted, 3-Pole, 40A
Art:
26130
Copied
|
3
|
63 A
|
Door-mounted
|
16
|
0,12 kg
|
40 A
|
40 A
|
40 A
|
40 A
|
40 A
|
40 A
|
40 A
|
25 A
|
25 A
|
22 kW
|
15 kW
|
22 kW
|
40 A
|
25 kA
|
4,5 kA
|
8 kV
|
320 A
|
200 A
|
200 A
|
| ||
RT 340 L42AD11LKX50, Door Mounted, 3-Pole, 40A with LKX50 handle
Art:
25777
Copied
|
3
|
63 A
|
Door-mounted
|
16
|
0,17 kg
|
40 A
|
40 A
|
40 A
|
40 A
|
40 A
|
40 A
|
40 A
|
25 A
|
25 A
|
22 kW
|
15 kW
|
22 kW
|
40 A
|
25 kA
|
4,5 kA
|
8 kV
|
320 A
|
200 A
|
200 A
|
| ||
RT 340 L42AD11LKX50YR, Door Mounted, 3-Pole, 40A with LKX50YR handle
Art:
25780
Copied
|
3
|
63 A
|
Door-mounted
|
16
|
0,17 kg
|
40 A
|
40 A
|
40 A
|
40 A
|
40 A
|
40 A
|
40 A
|
25 A
|
25 A
|
22 kW
|
15 kW
|
22 kW
|
40 A
|
25 kA
|
4,5 kA
|
8 kV
|
320 A
|
200 A
|
200 A
|
|
Select a variant in the list