CAL CONTROLS

CAL EDT2411,EDT2412, EDT2423 defrost thermostats

The EDT defrost thermostats have additional features to ensure optimum control and performance of a refrigeration system such as compressor protection, defrost control, real-time clock, communications and fast CAL-Key memory programming

 

  •  35 x 77mm
  •  On-Off control
  •  Relay output for cooling or heating control
  •  Single NTC probe input
  •  Offset value can be entered for NTC input
  •  Compressor protection parameters
  •  On probe failure, output status can be set to ON, OFF or periodic
  •  Upper and lower limits of the setpoint adjustment
  •  Defrost duration and interval can be adjusted
  •  6 different warning tones
  •  Deviation high and low alarm values
  •  Temperature unit can be selected °C or °F
  •  Digital input (Optional)
  •  External alarm
  •  Initiate defrost 

 

Read more
  • Compressor, defrost and fan control
  • Up to 2 NTC inputs
  • RS485 communications option
  • Real-time clock option

CAL Defrost thermostats

Selected variant

Selected variant

Technical data

Approvals CE, RoHS
Communication N/A
Control mode ON/OFF
Depth 61 mm
Digit height 12,5 mm
Frequency 50-60Hz
Input 1 x NTC
Input type 1 x NTC
IP class IP65
LED indication Red status LEDs
Number of digits 4
Output Relay
Output relay N/O
Outputs 20A, 277 Vac, resistive load
Panel size 35x77 mm
Power consumption 5 VA max
Storage temperature max 80 °C
Storage temperature min -25 °C
Supply voltage 115 V AC
Weight 190 g

Product description

The EDT defrost thermostats have additional features to ensure optimum control and performance of a refrigeration system such as compressor protection, defrost control, real-time clock, communications and fast CAL-Key memory programming

 

  •  35 x 77mm
  •  On-Off control
  •  Relay output for cooling or heating control
  •  Single NTC probe input
  •  Offset value can be entered for NTC input
  •  Compressor protection parameters
  •  On probe failure, output status can be set to ON, OFF or periodic
  •  Upper and lower limits of the setpoint adjustment
  •  Defrost duration and interval can be adjusted
  •  6 different warning tones
  •  Deviation high and low alarm values
  •  Temperature unit can be selected °C or °F
  •  Digital input (Optional)
  •  External alarm
  •  Initiate defrost 

 

Accessories

Related

automation components for specialist vehicles
Blog

Automation Components for Specialist Vehicles

The specialist vehicle industry can include automotive and EV, heavy vehicles such as agriculture and rail, and marine.  This email takes you through some of the various products we offer for specialist vehicle applications.

Wohner power distribution
Product news Blog

Modern Power Distribution

This blog post delves into the key components, current trends, and best practices in power distribution, illustrating the significant impact these systems have on our daily operations and long-term energy strategies.

Dehn lightning and surge protection
Product news Blog

Lightning and surge protection to safeguard equipment

We shine a spotlight on surge protection devices (SPDs), a crucial yet often overlooked component in industrial settings. Every surge of electricity, every fluctuation in voltage, poses a potential threat to your machinery and systems.

Klauke crimping stripping and punching tools
Product news

Efficient crimping, punching and stripping

Renowned for high-quality cable cutting and crimping tools, Klauke serves electrical contractors, cable jointers, and linemen across a spectrum of sectors

electro pneumatic control box customised bespoke solutions
Case studies

Case Study - Electro Pneumatic Control Box

At OEM Automatic, we can supply a series of components for your one project. All under one roof. This case study discusses how we supplied several components for our customer's new electro-pneumatic control box. 

Flexa e mobility cable protection, conduits and cable sleeves
Blog

Cable Protection For Emobility

To promote constant and reliable performance, as well as a longer life of parts in the vehicle, it is important to consider the right cable protector.

Parts Communication Input Input type Output Output relay Outputs Storage temperature max Supply voltage Price
N/A
1 x NTC
1 x NTC
Relay
N/O
20A, 277 Vac, resistive load
80 °C
115 V AC
RS-485
1 x NTC
1 x NTC
Relay
N/O
20A, 277 Vac, resistive load
80 °C
115 V AC
N/A
1 x NTC
1 x NTC
Relay
C/O
8A, 250 Vac, resistive load
80 °C
115 V AC
RS-485
1 x NTC
1 x NTC
Relay
C/O
8A, 250 Vac, resistive load
80 °C
115 V AC
N/A
1 x NTC
1 x NTC
Relay
C/O
8A, 250 Vac, resistive load
80 °C
115 V AC
RS-485
1 x NTC
1 x NTC
Relay
C/O
8A, 250 Vac, resistive load
80 °C
115 V AC
N/A
1 x NTC
1 x NTC
Relay
N/O
20A, 277 Vac, resistive load
80 °C
12 V AC/DC
RS-485
1 x NTC
1 x NTC
Relay
N/O
20A, 277 Vac, resistive load
80 °C
12 V AC/DC
N/A
1 x NTC
1 x NTC
Relay
C/O
8A, 250 Vac, resistive load
80 °C
12 V AC/DC
RS-485
1 x NTC
1 x NTC
Relay
C/O
8A, 250 Vac, resistive load
80 °C
12 V AC/DC
N/A
1 x NTC
1 x NTC
Relay
C/O
8A, 250 Vac, resistive load
80 °C
12 V AC/DC
RS-485
1 x NTC
1 x NTC
Relay
C/O
8A, 250 Vac, resistive load
80 °C
12 V AC/DC
N/A
1 x NTC
1 x NTC
Relay
N/O
20A, 277 Vac, resistive load
80 °C
230 V AC
RS-485
1 x NTC
1 x NTC
Relay
N/O
20A, 277 Vac, resistive load
80 °C
230 V AC
N/A
1 x NTC
1 x NTC
Relay
C/O
8A, 250 Vac, resistive load
80 °C
230 V AC
RS-485
1 x NTC
1 x NTC
Relay
C/O
8A, 250 Vac, resistive load
80 °C
230 V AC
N/A
1 x NTC
1 x NTC
Relay
C/O
8A, 250 Vac, resistive load
80 °C
230 V AC
RS-485
1 x NTC
1 x NTC
Relay
C/O
8A, 250 Vac, resistive load
80 °C
230 V AC
N/A
1 x NTC
1 x NTC
Relay
N/O
20A, 277 Vac, resistive load
80 °C
24 V AC/DC
RS-485
1 x NTC
1 x NTC
Relay
N/O
20A, 277 Vac, resistive load
80 °C
24 V AC/DC
N/A
1 x NTC
1 x NTC
Relay
C/O
8A, 250 Vac, resistive load
80 °C
24 V AC/DC
RS-485
1 x NTC
1 x NTC
Relay
C/O
8A, 250 Vac, resistive load
80 °C
24 V AC/DC
N/A
1 x NTC
1 x NTC
Relay
C/O
8A, 250 Vac, resistive load
80 °C
24 V AC/DC
RS-485
1 x NTC
1 x NTC
Relay
C/O
8A, 250 Vac, resistive load
80 °C
24 V AC/DC
N/A
1 x NTC
1 x NTC
2x Relay
1x C/O, 1x N/O
8A, 250 Vac, C/O; 20A, 277 Vac, N/O, resistive load
70 °C
115 V AC
RS-485
1 x NTC
1 x NTC
2x Relay
1x C/O, 1x N/O
8A, 250 Vac, C/O; 20A, 277 Vac, N/O, resistive load
70 °C
115 V AC
N/A
1 x NTC
1 x NTC
2x Relay
1x C/O, 1x N/O
2x 8A, 250 Vac, resistive load
70 °C
115 V AC
RS-485
1 x NTC
1 x NTC
2x Relay
1x C/O, 1x N/O
2x 8A, 250 Vac, resistive load
70 °C
115 V AC
N/A
1 x NTC
1 x NTC
2x Relay
1x C/O, 1x N/O
2x 8A, 250 Vac, resistive load
70 °C
115 V AC
RS-485
1 x NTC
1 x NTC
2x Relay
1x C/O, 1x N/O
2x 8A, 250 Vac, resistive load
70 °C
115 V AC
N/A
1 x NTC
1 x NTC
2x Relay
1x C/O, 1x N/O
8A, 250 Vac, C/O; 20A, 277 Vac, N/O, resistive load
70 °C
12 V AC/DC
RS-485
1 x NTC
1 x NTC
2x Relay
1x C/O, 1x N/O
8A, 250 Vac, C/O; 20A, 277 Vac, N/O, resistive load
70 °C
12 V AC/DC
N/A
1 x NTC
1 x NTC
2x Relay
1x C/O, 1x N/O
2x 8A, 250 Vac, resistive load
70 °C
12 V AC/DC
RS-485
1 x NTC
1 x NTC
2x Relay
1x C/O, 1x N/O
2x 8A, 250 Vac, resistive load
70 °C
12 V AC/DC
N/A
1 x NTC
1 x NTC
2x Relay
1x C/O, 1x N/O
2x 8A, 250 Vac, resistive load
70 °C
12 V AC/DC
RS-485
1 x NTC
1 x NTC
2x Relay
1x C/O, 1x N/O
2x 8A, 250 Vac, resistive load
70 °C
12 V AC/DC
N/A
1 x NTC
1 x NTC
2x Relay
1x C/O, 1x N/O
8A, 250 Vac, C/O; 20A, 277 Vac, N/O, resistive load
70 °C
230 V AC
RS-485
1 x NTC
1 x NTC
2x Relay
1x C/O, 1x N/O
8A, 250 Vac, C/O; 20A, 277 Vac, N/O, resistive load
70 °C
230 V AC
N/A
1 x NTC
1 x NTC
2x Relay
1x C/O, 1x N/O
2x 8A, 250 Vac, resistive load
70 °C
230 V AC
RS-485
1 x NTC
1 x NTC
2x Relay
1x C/O, 1x N/O
2x 8A, 250 Vac, resistive load
70 °C
230 V AC
N/A
1 x NTC
1 x NTC
2x Relay
1x C/O, 1x N/O
2x 8A, 250 Vac, resistive load
70 °C
230 V AC
RS-485
1 x NTC
1 x NTC
2x Relay
1x C/O, 1x N/O
2x 8A, 250 Vac, resistive load
70 °C
230 V AC
N/A
1 x NTC
1 x NTC
2x Relay
1x C/O, 1x N/O
8A, 250 Vac, C/O; 20A, 277 Vac, N/O, resistive load
70 °C
24 V AC/DC
RS-485
1 x NTC
1 x NTC
2x Relay
1x C/O, 1x N/O
8A, 250 Vac, C/O; 20A, 277 Vac, N/O, resistive load
70 °C
24 V AC/DC
N/A
1 x NTC
1 x NTC
2x Relay
1x C/O, 1x N/O
2x 8A, 250 Vac, resistive load
70 °C
24 V AC/DC
RS-485
1 x NTC
1 x NTC
2x Relay
1x C/O, 1x N/O
2x 8A, 250 Vac, resistive load
70 °C
24 V AC/DC
N/A
1 x NTC
1 x NTC
2x Relay
1x C/O, 1x N/O
2x 8A, 250 Vac, resistive load
70 °C
24 V AC/DC
RS-485
1 x NTC
1 x NTC
2x Relay
1x C/O, 1x N/O
2x 8A, 250 Vac, resistive load
70 °C
24 V AC/DC
N/A
2 x NTC
2 x NTC
3x Relay
1x C/O, 2x N/O
3x 8A, 250 Vac, resistive load
70 °C
115 V AC
RS-485
2 x NTC
2 x NTC
3x Relay
1x C/O, 2x N/O
3x 8A, 250 Vac, resistive load
70 °C
115 V AC
N/A
2 x NTC
2 x NTC
3x Relay
1x C/O, 2x N/O
3x 8A, 250 Vac, resistive load
70 °C
115 V AC
RS-485
2 x NTC
2 x NTC
3x Relay
1x C/O, 2x N/O
3x 8A, 250 Vac, resistive load
70 °C
115 V AC
N/A
2 x NTC
2 x NTC
3x Relay
1x C/O, 2x N/O
3x 8A, 250 Vac, resistive load
70 °C
12 V AC/DC
RS-485
2 x NTC
2 x NTC
3x Relay
1x C/O, 2x N/O
3x 8A, 250 Vac, resistive load
70 °C
12 V AC/DC
N/A
2 x NTC
2 x NTC
3x Relay
1x C/O, 2x N/O
3x 8A, 250 Vac, resistive load
70 °C
12 V AC/DC
RS-485
2 x NTC
2 x NTC
3x Relay
1x C/O, 2x N/O
3x 8A, 250 Vac, resistive load
70 °C
12 V AC/DC
N/A
2 x NTC
2 x NTC
3x Relay
1x C/O, 2x N/O
3x 8A, 250 Vac, resistive load
70 °C
230 V AC
RS-485
2 x NTC
2 x NTC
3x Relay
1x C/O, 2x N/O
3x 8A, 250 Vac, resistive load
70 °C
230 V AC
N/A
2 x NTC
2 x NTC
3x Relay
1x C/O, 2x N/O
3x 8A, 250 Vac, resistive load
70 °C
230 V AC
RS-485
2 x NTC
2 x NTC
3x Relay
1x C/O, 2x N/O
3x 8A, 250 Vac, resistive load
70 °C
230 V AC
N/A
2 x NTC
2 x NTC
3x Relay
1x C/O, 2x N/O
3x 8A, 250 Vac, resistive load
70 °C
24 V AC/DC
RS-485
2 x NTC
2 x NTC
3x Relay
1x C/O, 2x N/O
3x 8A, 250 Vac, resistive load
70 °C
24 V AC/DC
N/A
2 x NTC
2 x NTC
3x Relay
1x C/O, 2x N/O
3x 8A, 250 Vac, resistive load
70 °C
24 V AC/DC
RS-485
2 x NTC
2 x NTC
3x Relay
1x C/O, 2x N/O
3x 8A, 250 Vac, resistive load
70 °C
24 V AC/DC

Selected variant

Select a variant in the list

Contact us

If you need any help, you can contact us in one of the following ways:

phone 0116 284 9900

Send an e-mail Send an e-mail

comments Use live chat