CONTA-CLIP
Test-disconnect terminals are mostly used in the sectors of electricity generation and supply.They are tailored to the variety of switching
demands for current-converter secondary circuits that predominate in these sectors. Current transformers must always have a secondary
circuit when electricity meters and measuring instruments are being replaced, or when making comparative measurements.
CONTA-CLIP test-disconnect terminals are available in the following three basic versions, each with or without a pre-assembled socket plug.
All versions provide touch-safe protection according to DGUV-3.
A captive, screw-on sliding partition is used to separate the current and voltage paths.
The switch position is always easy to detect since the disconnect screw has a yellow insulating sleeve.
Â
In all versions, the STB 14/4 socket plugs can be used for a test pick-off for measuring values using the PS 4 test plug or the conventional (4 mm) insulated test plugs.
Â
The VH 19 connecting sleeves and the BS 25 screws or STB 14/4 socket plugs are required for fastening the QVS cross-switches above the terminal block. The cross-switches  are available from 2 to 4 poles.
The QSB internal cross-switches are positioned within the terminal block and make contact over the sliding contact on the LT- or QT-terminals. The cross-switches are available from 2 to 4 poles.
The BS 25 mounting screws are used together with the VH 19 connecting sleeves to establish contact with the QVS cross-switches.
Â
General data |
|
---|---|
Rated wire cross section | 10 mm² |
Colour | Beige |
Rated voltage IEC | 400 V |
Rated current IEC | 10 A |
Mounting | TS 35 and TS 32 |
Rated impulse voltage | 4 kV |
Overvoltage category | III |
Contamination degree | 3 |
Approvals | CSA, CSA US |
Dimensions |
|
Length | 72 mm |
Width | 8 mm |
Height TS 35/7.5 | 47 mm |
Height TS 32 | 51,5 mm |
Connection data |
|
Connections | 2 |
Number of levels | 1 |
Plug gauge acc. EN 60 947-1 | A5 |
Cross connect channels | 2 |
Cross section single wire from | 0,2 mm² |
Cross section single wire to | 10 mm² |
Cross section stranded wire from | 0,2 mm² |
Cross section stranded wire to | 10 mm² |
Cross section stranded with ferrule from | 0,2 mm² |
Cross section stranded with ferrule to | 10 mm² |
*Invisible Heading* |
|
---|---|
Rated wire cross section from (AWG) | 8 |
Rated wire cross section to (AWG) | 22 |
Stripping length | 12 mm |
Screw size | M 4 |
Screw type | Slotted |
Torque min | 1,2 Nm |
Torque max | 2 Nm |
Materials |
|
Insulation material | Polyamide 6.6 |
Flammability class | UL94-V2 |
Operating temperature from | -40 °C |
Operating temperature to | 105 °C |
Approvals |
|
Rated voltage CSA | 600 V |
Rated current CSA | 45 A |
CSA test standard | C22.2 No 158 |
Rated voltage CSAus | 600 V |
Rated current CSAus | 45 A |
CSAus test standard | UL 1059 |
Additional data |
|
Tariff code | 85369010 |
Country of origin | DE |
Weight | 24,66 g |
Pack size | 50 |
Test-disconnect terminals are mostly used in the sectors of electricity generation and supply.They are tailored to the variety of switching
demands for current-converter secondary circuits that predominate in these sectors. Current transformers must always have a secondary
circuit when electricity meters and measuring instruments are being replaced, or when making comparative measurements.
CONTA-CLIP test-disconnect terminals are available in the following three basic versions, each with or without a pre-assembled socket plug.
All versions provide touch-safe protection according to DGUV-3.
A captive, screw-on sliding partition is used to separate the current and voltage paths.
The switch position is always easy to detect since the disconnect screw has a yellow insulating sleeve.
Â
In all versions, the STB 14/4 socket plugs can be used for a test pick-off for measuring values using the PS 4 test plug or the conventional (4 mm) insulated test plugs.
Â
The VH 19 connecting sleeves and the BS 25 screws or STB 14/4 socket plugs are required for fastening the QVS cross-switches above the terminal block. The cross-switches  are available from 2 to 4 poles.
The QSB internal cross-switches are positioned within the terminal block and make contact over the sliding contact on the LT- or QT-terminals. The cross-switches are available from 2 to 4 poles.
The BS 25 mounting screws are used together with the VH 19 connecting sleeves to establish contact with the QVS cross-switches.
Â
This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.
We are thrilled to announce the launch of IATECH, THe Industrial Automation Technology expo at Leicester Marriott Hotel on 23rd October. The ultimate platform for showcasing our extensive product range and broad business areas, featuring over 50 leading suppliers under one roof!
The specialist vehicle industry can include automotive and EV, heavy vehicles such as agriculture and rail, and marine. This email takes you through some of the various products we offer for specialist vehicle applications.
This blog post delves into the key components, current trends, and best practices in power distribution, illustrating the significant impact these systems have on our daily operations and long-term energy strategies.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Approvals | Additional information | Width | Height TS 35/7.5 | Height TS 32 | Cross connect channels | Number of test pick off options | Rated voltage CSA | Rated current CSA | CSA test standard | Rated voltage CSAus | Rated current CSAus | CSAus test standard | Weight | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PTK 10/LT , Test-disconnect terminal
Art:
1130.2
Copied
|
CSA, CSA US
|
|
8 mm
|
47 mm
|
51,5 mm
|
2
|
|
600 V
|
45 A
|
C22.2 No 158
|
600 V
|
45 A
|
UL 1059
|
24,66 g
|
| ||
PTK 10/LT/STB, Test-disconnect terminal with sockets
Art:
1131.2
Copied
|
CSA, CSA US
|
with sockets
|
8 mm
|
47 mm
|
51,5 mm
|
|
2
|
600 V
|
45 A
|
C22.2 No 158
|
600 V
|
45 A
|
UL 1059
|
28,9 g
|
| ||
PTK 10/QT, Test-disconnect terminal, separated perpendicularly
Art:
1132.2
Copied
|
CSA, CSA US
|
|
8 mm
|
47 mm
|
51,5 mm
|
2
|
|
600 V
|
45 A
|
C22.2 No 158
|
600 V
|
45 A
|
UL 1059
|
25,14 g
|
| ||
PTK 10/QT, Test-disconnect terminal with sockets, separated perpendicularly
Art:
1133.2
Copied
|
CSA, CSA US
|
with sockets
|
8 mm
|
47 mm
|
51,5 mm
|
|
2
|
600 V
|
45 A
|
C22.2 No 158
|
600 V
|
45 A
|
UL 1059
|
29,74 g
|
| ||
PTK 10/DU, Test-disconnect feed through terminal
Art:
1134.2
Copied
|
CSA, CSA US
|
|
8 mm
|
47 mm
|
51,5 mm
|
2
|
|
600 V
|
45 A
|
C22.2 No 158
|
600 V
|
45 A
|
UL 1059
|
22,56 g
|
| ||
PTK 10/DU/STB,Test-disconnect feed through terminal with sockets
Art:
1135.2
Copied
|
CSA, CSA US
|
with sockets
|
8 mm
|
47 mm
|
51,5 mm
|
|
2
|
600 V
|
45 A
|
C22.2 No 158
|
600 V
|
45 A
|
UL 1059
|
22,56 g
|
| ||
PTK 10/LT/HB, Test-disconnect terminal, Finger screw operated
Art:
17366.2
Copied
|
|
hand lever
|
8 mm
|
63 mm
|
67,5 mm
|
2
|
|
|
|
|
|
|
|
31,66 g
|
| ||
PTK 10/LT/STB/HB, Test-disconnect terminal with sockets, Finger screw operated
Art:
17367.2
Copied
|
|
hand lever
|
8 mm
|
63 mm
|
67,5 mm
|
|
2
|
|
|
|
|
|
|
35,86 g
|
| ||
Eco CT- LINK Assembly Single Phase without test probe connections
Art:
87780.0
Copied
|
CSA, CSA US
|
|
18 mm
|
47 mm
|
51,5 mm
|
2
|
|
600 V
|
45 A
|
C22.2 No 158
|
600 V
|
45 A
|
UL 1059
|
60 g
|
| ||
CT- LINK Assembly Single Phase with test probe sockets
Art:
820100000008
Copied
|
CSA, CSA US
|
with sockets
|
18 mm
|
47 mm
|
51,5 mm
|
2
|
2
|
600 V
|
45 A
|
C22.2 No 158
|
600 V
|
45 A
|
UL 1059
|
64 g
|
| ||
CT - LINK 2 Assembly 3-Phase with voltage feed trough terminals and test probe sockets
Art:
820100000009
Copied
|
CSA, CSA US
|
with sockets
|
84 mm
|
47 mm
|
51,5 mm
|
2
|
14
|
600 V
|
45 A
|
C22.2 No 158
|
600 V
|
45 A
|
UL 1059
|
283 g
|
| ||
CT-LINK 3 Assembly 3-Phase with Voltage Disconnects and test probe sockets
Art:
820100000010
Copied
|
CSA, CSA US
|
with sockets
|
84 mm
|
47 mm
|
51,5 mm
|
2
|
14
|
600 V
|
45 A
|
C22.2 No 158
|
600 V
|
45 A
|
UL 1059
|
287 g
|
|
Select a variant in the list