LUMEL
The RP3 power controller is a contactless three-phase power energy electronic device which includes a thyristor connector and an electronic gate triggering system. (GTS)
This power controller allows the control of the power delivered from a three-phase voltage source to an electrical energy load in function of the control signal input. The RP3 power controller is destined for three-phase actuators with resistance or resistance-inductance loads in control systems and automatic temperature control.
The application area of RP3 power controllers comprises:
• electrical furnaces and drying constructions, particularly industrial tunnels and belt- type furnaces, furnaces for annealing and hard soldering, crucible furnaces and smelters, furnaces for hardening in salt baths
• devices of mechanical engineering, aggregates and extruding presses for plastics, devices, for winding and tempering of springs, spot welding and seam welders
• production of glass and glazing, installations and devices for drying in infrared and ultraviolet radiation, ladles for glass melt and heating of feeding devices, furnaces for glass forming• chemical and petroleum industries, facing heaters of tube installations, preheating installations
KINDS OF CONTROL
• On-off control
• Chopper control:
o fast cycle - fi,max » 1 Hz
o slow cycle - fi,max » 0.1 Hz
o Phase control
ADDITIONAL FUNCTIONS
• Load current limitation
• Delay of soft start tripping type
• Control of the initial gating angle value
• Control of the input line amplification
• Supervising and signalling of the current in the load circuit, output U= f(lo)
• Supervising of the radiator temperature
• Signalling of the fuse damage
• Signalling of the incorrect phase sequence
• Signalling of overload
• Relay outputs
Â
Dimensions | 212 x 318 x 177 mm |
---|---|
Output | Maximum output current 125A |
Temperature operational max | 40 °C |
Temperature operational min | 0 °C |
Weight | 8,5 kg |
The RP3 power controller is a contactless three-phase power energy electronic device which includes a thyristor connector and an electronic gate triggering system. (GTS)
This power controller allows the control of the power delivered from a three-phase voltage source to an electrical energy load in function of the control signal input. The RP3 power controller is destined for three-phase actuators with resistance or resistance-inductance loads in control systems and automatic temperature control.
The application area of RP3 power controllers comprises:
• electrical furnaces and drying constructions, particularly industrial tunnels and belt- type furnaces, furnaces for annealing and hard soldering, crucible furnaces and smelters, furnaces for hardening in salt baths
• devices of mechanical engineering, aggregates and extruding presses for plastics, devices, for winding and tempering of springs, spot welding and seam welders
• production of glass and glazing, installations and devices for drying in infrared and ultraviolet radiation, ladles for glass melt and heating of feeding devices, furnaces for glass forming• chemical and petroleum industries, facing heaters of tube installations, preheating installations
KINDS OF CONTROL
• On-off control
• Chopper control:
o fast cycle - fi,max » 1 Hz
o slow cycle - fi,max » 0.1 Hz
o Phase control
ADDITIONAL FUNCTIONS
• Load current limitation
• Delay of soft start tripping type
• Control of the initial gating angle value
• Control of the input line amplification
• Supervising and signalling of the current in the load circuit, output U= f(lo)
• Supervising of the radiator temperature
• Signalling of the fuse damage
• Signalling of the incorrect phase sequence
• Signalling of overload
• Relay outputs
Â
This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.
We are thrilled to announce the launch of IATECH, THe Industrial Automation Technology expo at Leicester Marriott Hotel on 23rd October. The ultimate platform for showcasing our extensive product range and broad business areas, featuring over 50 leading suppliers under one roof!
The specialist vehicle industry can include automotive and EV, heavy vehicles such as agriculture and rail, and marine. This email takes you through some of the various products we offer for specialist vehicle applications.
This blog post delves into the key components, current trends, and best practices in power distribution, illustrating the significant impact these systems have on our daily operations and long-term energy strategies.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Dimensions | Output | Price | ||
---|---|---|---|---|---|
LUMEL RP3 PWR CONT (3-PH) 125A 400VAC
Art:
RP338
Copied
|
212 x 318 x 177 mm
|
Maximum output current 125A
|
| ||
LUMEL RP3 PWR CONT (3-PH) 40A 400VAC
Art:
RP318
Copied
|
212 x 318 x 177 mm
|
Maximum output current 40A
|
| ||
LUMEL RP3 PWR CONT (3-PH) 450A 400VAC
Art:
RP368
Copied
|
383 x 433 x 281 mm
|
Maximum output current 450A
|
| ||
LUMEL RP3 PWR CONT (3-PH) 70A 400VAC
Art:
RP328
Copied
|
212 x 318 x 177 mm
|
Maximum output current 70A
|
|
Select a variant in the list