APLISENS
The SGE-25 hydrostatic level probe measures liquid levels in tanks, deep wells or piezometers. Â Its specialised design means it can measure water levels in very narrow conditions.
Â
Its operation is based on a simple relationship between the height of the liquid column and the resulting hydrostatic pressure. Â Applications include pumping stations, fermentation chambers, settling tanks, borehole levels and ponds.
Â
When the probe is lowered to the reference level it can either hang freely or lie on the bottom. Â If there is a possibility of turbulence in the tank (for example mixer operation or a turbulent inflow) then the probe should be installed inside a screening tube (e.g. made of PVC). Â Cleaning the probe diaphragm by mechanical means is strictly prohibited. Â The SGE-25 uses HART protocol and can be configured using the following metrological parameters:
Â
Â
Â
Through the data interchange with the probe you can also:
Â
Â
Options include Exia, thread on cable entry, titanium wetted parts, DNV approval, cable options and higher temperature rating.
Â
Cable length | 5 m |
---|---|
Deviation max | 0,1 % |
IP class | IP68 |
Material cable | PUR |
Material of body | Stainless steel 316L |
Material of wetted parts | Hastelloy C, Stainless Steel SIS2350 (316L) |
Pressure range max | 1 mH2O |
Pressure range min | 0 mH2O |
---|---|
Signal type | 4-20 mA / Hart |
Supply voltage dc max | 55 V DC |
Supply voltage dc min | 7,5 V DC |
Temperature of media from | -30 °C |
Temperature of media to | 40 °C |
The SGE-25 hydrostatic level probe measures liquid levels in tanks, deep wells or piezometers. Â Its specialised design means it can measure water levels in very narrow conditions.
Â
Its operation is based on a simple relationship between the height of the liquid column and the resulting hydrostatic pressure. Â Applications include pumping stations, fermentation chambers, settling tanks, borehole levels and ponds.
Â
When the probe is lowered to the reference level it can either hang freely or lie on the bottom. Â If there is a possibility of turbulence in the tank (for example mixer operation or a turbulent inflow) then the probe should be installed inside a screening tube (e.g. made of PVC). Â Cleaning the probe diaphragm by mechanical means is strictly prohibited. Â The SGE-25 uses HART protocol and can be configured using the following metrological parameters:
Â
Â
Â
Through the data interchange with the probe you can also:
Â
Â
Options include Exia, thread on cable entry, titanium wetted parts, DNV approval, cable options and higher temperature rating.
Â
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Cable length | Material cable | Pressure range max | Price | ||
---|---|---|---|---|---|---|
0..1mH2O, 4-20mA/Hart, 5m PU cable
Art:
SGE25S0001.001
Copied
|
5 m
|
PUR
|
1 mH2O
|
| ||
0..1mH2O, 4-20mA/Hart, 10m PU cable
Art:
SGE25S0001.000
Copied
|
10 m
|
PUR
|
1 mH2O
|
| ||
0..1,6mH2O, 4-20mA/Hart, 10m PU cable
Art:
SGE25S01.6.000
Copied
|
10 m
|
PUR
|
1,6 mH2O
|
| ||
0..2mH2O, 4-20mA/Hart, 10m PU cable
Art:
SGE25S0002.000
Copied
|
10 m
|
PUR
|
2 mH2O
|
| ||
0..2,5mH2O, 4-20mA/Hart, 10m PU cable
Art:
SGE25S02.5.000
Copied
|
10 m
|
PUR
|
2,5 mH2O
|
| ||
0..4mH2O, 4-20mA/Hart, 10m PU cable
Art:
SGE25S0004.000
Copied
|
10 m
|
PUR
|
4 mH2O
|
| ||
0..4mH2O, 4-20mA/Hart, 7m PU cable
Art:
SGE25S0004.001
Copied
|
7 m
|
PUR
|
4 mH2O
|
| ||
0..6mH2O, 4-20mA/Hart, 10m PU cable
Art:
SGE25S0006.000
Copied
|
10 m
|
PUR
|
6 mH2O
|
| ||
0..10mH2O, 4-20mA/Hart, 10m PU cable
Art:
SGE25S0010.000
Copied
|
10 m
|
PUR
|
10 mH2O
|
| ||
Art:
SGE25S0010.001
Copied
|
15 m
|
PUR/halogen free
|
10 mH2O
|
| ||
0..10mH2O, 4-20mA/Hart, 20m PU cable
Art:
SGE25S0010.002
Copied
|
20 m
|
PUR
|
10 mH2O
|
|
Select a variant in the list
Contact us