Important notice - Our website is under going construction, therefore you may notice some issues. Please bare with us and contact or customer support team if you need any product information - 0116 284 9900
AVENTICS
The pressure regulator lowers the inlet pressure to the set outlet pressure.
This pressure is kept constant as long as the inlet pressure is higher than the set outlet pressure.
The adjustment is done by pulling the adjusting wheel upwards before it can be turned to set the desired working pressure. When the pressure is reached, the adjusting wheel is pressed down to lock it in position.
This ensures that the set pressure does not change accidentally.
Connection air | G1 |
---|---|
Control range max | 10 bar |
Control range min | 0,5 bar |
Function | Pressure regulator |
Manometer | No |
Material of seals | NBR |
Material protection | Polyamide |
Media | Air pressure |
Nominal flow | 14500 l/min |
---|---|
Operating pressure max | 16 bar |
Operating pressure min | 0,5 bar |
Temperature operational max | 50 °C |
Temperature operational min | -10 °C |
Weight | 0,905 kg |
The pressure regulator lowers the inlet pressure to the set outlet pressure.
This pressure is kept constant as long as the inlet pressure is higher than the set outlet pressure.
The adjustment is done by pulling the adjusting wheel upwards before it can be turned to set the desired working pressure. When the pressure is reached, the adjusting wheel is pressed down to lock it in position.
This ensures that the set pressure does not change accidentally.