SUCO
Initially developed for automotive purposes CAN is a serial bus protocol which allows components such as sensors to communicate over a single or dual wired network to a vehicles system. This vastly reduces the amount of cable used, wiring time and connections used in standard wiring looms whilst still communicating data at high speeds.
Â
Housed in a robust stainless steel case this sensor meets the high demands of harsh environments whilst still offering excellent accuracy and reliability. Pressure ranges start from 0..1 bar and go all the way up to 0..600 bar covering most application requirements.
Â
Wide range of applications such as agricultural, rail, off-highway and construction vehicles etc.
Accuracy | ±0.5% FS |
---|---|
Burst pressure | 9 bar |
Connection | G1/4-E |
Electrical connection | M12x1 |
IP class | IP67 |
Long term stability | <±0.1% of full scale per year |
Material of body | Stainless Steel 1.4301 |
Material of wetted parts | Stainless steel 1.4542 |
Mechanical life expectancy | 10 Million cycles |
Overpressure protection | 6 Bar |
Pressure range max | 1 bar |
Pressure range min | 0 bar |
Pressure reference | Gauge |
Pressure rise | ≤ 1 bar/ms |
Repeatability | ±0.1% FS |
---|---|
Response time | 1 ms |
Shock resistance | 1000g according to IEC68-2-32 |
Signal type | CANopen, CAN 2.0 A |
Supply voltage dc max | 32 V DC |
Supply voltage dc min | 10 V DC |
Temperature ambient from | -40 °C |
Temperature ambient to | 105 °C |
Temperature error | 1.5% FS |
Temperature of media from | -40 °C |
Temperature of media to | 100 °C |
Weight | 90 g |
Vibration resistance | 20g according to IEC 68-2-6 and IEC 68-2-36 |
Initially developed for automotive purposes CAN is a serial bus protocol which allows components such as sensors to communicate over a single or dual wired network to a vehicles system. This vastly reduces the amount of cable used, wiring time and connections used in standard wiring looms whilst still communicating data at high speeds.
Â
Housed in a robust stainless steel case this sensor meets the high demands of harsh environments whilst still offering excellent accuracy and reliability. Pressure ranges start from 0..1 bar and go all the way up to 0..600 bar covering most application requirements.
Â
Wide range of applications such as agricultural, rail, off-highway and construction vehicles etc.
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
Did you know that OEM Automatic has been successfully providing valve actuation solutions?
We are thrilled to announce the launch of IATECH, THe Industrial Automation Technology expo at Leicester Marriott Hotel on 23rd October. The ultimate platform for showcasing our extensive product range and broad business areas, featuring over 50 leading suppliers under one roof!
The specialist vehicle industry can include automotive and EV, heavy vehicles such as agriculture and rail, and marine. This email takes you through some of the various products we offer for specialist vehicle applications.
At OEM Automatic, we can supply a series of components for your one project. All under one roof. This case study discusses how we supplied several components for our customer's new electro-pneumatic control box.Â
OEM is pleased to announce a range of hydrogen-approved mechanical pressure switches, by Suco! Today, hydrogen plays a key role in climate-neutral energy generation and storage.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Burst pressure | Overpressure protection | Pressure range max | Signal type | Price | ||
---|---|---|---|---|---|---|---|
CANopen, 0..1Bar, G¼, M12
Art:
063010041B032
Copied
|
9 bar
|
6 Bar
|
1 bar
|
CANopen, CAN 2.0 A
|
| ||
CANopen, 0..10Bar, G¼, M12
Art:
063010141B032
Copied
|
30 bar
|
20 Bar
|
10 bar
|
CANopen, CAN 2.0 A
|
| ||
CANopen, 0..100Bar, G¼, M12
Art:
063010241B032
Copied
|
300 bar
|
200 Bar
|
100 bar
|
CANopen, CAN 2.0 A
|
| ||
CANopen, 0..16Bar, G¼, M12
Art:
063016141B032
Copied
|
60 bar
|
40 Bar
|
16 bar
|
CANopen, CAN 2.0 A
|
| ||
CANopen, 0..160Bar, G¼, M12
Art:
063016241B032
Copied
|
600 bar
|
400 Bar
|
160 bar
|
CANopen, CAN 2.0 A
|
| ||
CANopen, 0..250Bar, G¼, M12
Art:
063025041B032
Copied
|
9 bar
|
6 Bar
|
2,5 bar
|
CANopen, CAN 2.0 A
|
| ||
CANopen, 0..25Bar, G¼, M12
Art:
063025141B032
Copied
|
150 bar
|
100 Bar
|
25 bar
|
CANopen, CAN 2.0 A
|
| ||
CANopen, 0..250Bar, G¼, M12
Art:
063025241B032
Copied
|
1000 bar
|
750 Bar
|
250 bar
|
CANopen, CAN 2.0 A
|
| ||
CANopen, 0..4Bar, G¼, M12
Art:
063040041B032
Copied
|
15 bar
|
10 Bar
|
4 bar
|
CANopen, CAN 2.0 A
|
| ||
CANopen, 0..40Bar, G¼, M12
Art:
063040141B032
Copied
|
150 bar
|
100 Bar
|
40 bar
|
CANopen, CAN 2.0 A
|
| ||
CANopen, 0..400Bar, G¼, M12
Art:
063040241B032
Copied
|
1000 bar
|
750 Bar
|
400 bar
|
CANopen, CAN 2.0 A
|
| ||
CANopen, 0..6Bar, G¼, M12
Art:
063060041B032
Copied
|
30 bar
|
20 Bar
|
6 bar
|
CANopen, CAN 2.0 A
|
| ||
CANopen, 0..60Bar, G¼, M12
Art:
063060141B032
Copied
|
300 bar
|
200 Bar
|
60 bar
|
CANopen, CAN 2.0 A
|
| ||
CANopen, 0..600Bar, G¼, M12
Art:
063060241B032
Copied
|
1050 bar
|
840 Bar
|
600 bar
|
CANopen, CAN 2.0 A
|
| ||
CAN J1939, 0..1Bar, G¼, M12
Art:
063110041B032
Copied
|
9 bar
|
6 Bar
|
1 bar
|
CAN J1939, CAN 2.0 B
|
| ||
CAN J1939, 0..10Bar, G¼, M12
Art:
063110141B032
Copied
|
30 bar
|
20 Bar
|
10 bar
|
CAN J1939, CAN 2.0 B
|
| ||
CAN J1939, 0..100Bar, G¼, M12
Art:
063110241B032
Copied
|
300 bar
|
200 Bar
|
100 bar
|
CAN J1939, CAN 2.0 B
|
| ||
CAN J1939, 0..16Bar, G¼, M12
Art:
063116141B032
Copied
|
60 bar
|
40 Bar
|
16 bar
|
CAN J1939, CAN 2.0 B
|
| ||
CAN J1939, 0..160Bar, G¼, M12
Art:
063116241B032
Copied
|
600 bar
|
400 Bar
|
160 bar
|
CAN J1939, CAN 2.0 B
|
| ||
CAN J1939, 0..2,5Bar, G¼, M12
Art:
063125041B032
Copied
|
9 bar
|
6 Bar
|
2,5 bar
|
CAN J1939, CAN 2.0 B
|
| ||
CAN J1939, 0..25Bar, G¼, M12
Art:
063125141B032
Copied
|
150 bar
|
100 Bar
|
25 bar
|
CAN J1939, CAN 2.0 B
|
| ||
CAN J1939, 0..250Bar, G¼, M12
Art:
063125241B032
Copied
|
1000 bar
|
750 Bar
|
250 bar
|
CAN J1939, CAN 2.0 B
|
| ||
CAN J1939, 0..4Bar, G¼, M12
Art:
063140041B032
Copied
|
15 bar
|
10 Bar
|
4 bar
|
CAN J1939, CAN 2.0 B
|
| ||
CAN J1939, 0..40Bar, G¼, M12
Art:
063140141B032
Copied
|
150 bar
|
100 Bar
|
40 bar
|
CAN J1939, CAN 2.0 B
|
| ||
CAN J1939, 0..400Bar, G¼, M12
Art:
063140241B032
Copied
|
1000 bar
|
750 Bar
|
400 bar
|
CAN J1939, CAN 2.0 B
|
| ||
CAN J1939, 0..6Bar, G¼, M12
Art:
063160041B032
Copied
|
30 bar
|
20 Bar
|
6 bar
|
CAN J1939, CAN 2.0 B
|
| ||
CAN J1939, 0..60Bar, G¼, M12
Art:
063160141B032
Copied
|
300 bar
|
200 Bar
|
60 bar
|
CAN J1939, CAN 2.0 B
|
| ||
CAN J1939, 0..600Bar, G¼, M12
Art:
063160241B032
Copied
|
1050 bar
|
840 Bar
|
600 bar
|
CAN J1939, CAN 2.0 B
|
|
Select a variant in the list