IDEM
A coded magnetic switch made of stainless steel with a small size and high tolerance, which is ideally suited for applications in the food and pharmaceutical industries. The switch has a standard spacing of fixing holes - 22 mm and is resistant to pressure washing. Mounting screws from the bottom makes the switch ideal for demanding food applications.
Approvals | ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508 |
---|---|
Cable length | 2 m |
Cable type | PVC 6 or 8 core 6mm OD Conductors 0.25mm² |
Coding | Coded magnetic actuation |
Conductor size | 0,25 mm² |
Contact rating max | 24Vdc 0.2A |
Contacts | 2NC |
Housing material | Stainless steel 316 |
Integrated LED indication | Yes |
IP class | IP69K, IP67 |
Mounting | 2 x M4 |
MTTFd | 866 years |
---|---|
Operating temperature | -25..105°C |
PFHd | 8.71 X 10⁻¹¹ |
PL | e acc. ISO13849-1 |
Recommended mounting gap | 5 mm |
SIL | 3 acc. EN62061 |
Switching current min | 10Vdc 1mA |
Switching distance | Sao 10mm close, Sar 20mm open |
Switching frequency max | 1.0Hz maximum |
A coded magnetic switch made of stainless steel with a small size and high tolerance, which is ideally suited for applications in the food and pharmaceutical industries. The switch has a standard spacing of fixing holes - 22 mm and is resistant to pressure washing. Mounting screws from the bottom makes the switch ideal for demanding food applications.
We’re thrilled to welcome Tony Maton, our new Sales Engineer at OEM Automatic! Tony brings a wealth of knowledge and expertise in industrial automation and machine safety
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
We are thrilled to announce the launch of IATECH, THe Industrial Automation Technology expo at Leicester Marriott Hotel on 23rd October. The ultimate platform for showcasing our extensive product range and broad business areas, featuring over 50 leading suppliers under one roof!
The specialist vehicle industry can include automotive and EV, heavy vehicles such as agriculture and rail, and marine. This email takes you through some of the various products we offer for specialist vehicle applications.
If you're looking for more speed and accuracy, this new contrast sensor will work for you.
Do you need help with the safety of your industrial doors, gates, or high-speed doors? Whether you require safety edges, light curtains, safety bumpers, or complete control systems, we can help.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Approvals | Cable length | Contacts | Operating temperature | PL | SIL | Switching distance | Price | ||
---|---|---|---|---|---|---|---|---|---|---|
SMC-F 2M '2NC' with LED
Art:
137001
Copied
|
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
|
2 m
|
2NC
|
-25..105°C
|
e acc. ISO13849-1
|
3 acc. EN62061
|
|
| ||
SMC-F 5M '2NC' with LED
Art:
137002
Copied
|
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
|
5 m
|
2NC
|
-25..105°C
|
e acc. ISO13849-1
|
3 acc. EN62061
|
|
| ||
SMC-F 10M '2NC' with LED
Art:
137003
Copied
|
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
|
10 m
|
2NC
|
-25..105°C
|
e acc. ISO13849-1
|
3 acc. EN62061
|
|
| ||
SMC-F QC M12 8way '2NC' with LED
Art:
137004
Copied
|
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
|
0,25 m
|
2NC
|
-25..105°C
|
e acc. ISO13849-1
|
3 acc. EN62061
|
|
| ||
SMC-F 2M '2NC 1NO' with LED
Art:
137005
Copied
|
ISO 13849-1, ISO 14119, EN60204-1, EN62061, EN60947-5-1, CE, cULus, TÜV, UL 508
|
2 m
|
2NC 1NO
|
-25°C - 105°C
|
up to PLe acc. ISO13849-1
|
|
14 mm
|
| ||
SMC-F 5M '2NC 1NO' with LED
Art:
137006
Copied
|
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
|
5 m
|
2NC 1NO
|
-25..105°C
|
e acc. ISO13849-1
|
3 acc. EN62061
|
|
| ||
SMC-F 10M '2NC 1NO' with LED
Art:
137007
Copied
|
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
|
10 m
|
2NC 1NO
|
-25..105°C
|
e acc. ISO13849-1
|
3 acc. EN62061
|
|
| ||
SMC-F QC M12 8way '2NC 1NO' with LED
Art:
137008
Copied
|
ISO 13849-1, ISO 14119, EN60204-1, EN62061, EN60947-5-1, CE, cULus, TÜV, UL 508
|
0,25 m
|
2NC 1NO
|
-25°C - 105°C
|
up to PLe acc. ISO13849-1
|
|
14 mm
|
| ||
SMC-F 2M '3NC' with LED
Art:
137105
Copied
|
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
|
2 m
|
3NC
|
-25..105°C
|
e acc. ISO13849-1
|
3 acc. EN62061
|
|
| ||
SMC-F 5M '3NC' with LED
Art:
137106
Copied
|
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
|
5 m
|
3NC
|
-25..105°C
|
e acc. ISO13849-1
|
3 acc. EN62061
|
|
| ||
SMC-F 10M '3NC' with LED
Art:
137107
Copied
|
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
|
10 m
|
3NC
|
-25..105°C
|
e acc. ISO13849-1
|
3 acc. EN62061
|
|
| ||
SMC-F QC M12 8way '3NC' with LED
Art:
137108
Copied
|
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
|
0,25 m
|
3NC
|
-25..105°C
|
e acc. ISO13849-1
|
3 acc. EN62061
|
|
|