The MGL range of Non Contact RFID Coded switches has been developed in order to provide and maintain a high level of functional safety whilst providing a reliable magnetic door interlock.
Flexibility for holding force is provided by the provision of 2 different switch sizes - Heavy Duty (1100N (F1Max) Stainless Steel and Medium Duty (600N (F1Max) Stainless Steel to cover all applications.
Coding is achieved by using magnetic and RFID techniques and both principles need to be satisfied for the switch to operate safely.
The MGL range will connect to the majority of popular standard safety relays to achieve up to PLe/Category 4 to ISO13849-1.
The Stainless Steel 316 version has been designed with a Stainless Steel magnet and IP69K rating making it suitable for CIP and SIP processes.
RFID coding options
The RFID coding is offered in two types and can be either coded by series or uniquely coded.
Type 1: Master Code - by series (any actuator will operate any switch) this is used when unique door activation is not required, but the benefit of RFID makes it virtually impossible to be overridden or by-passed by simple means.
Type 2: 32,000,000 Unique Codes - the switch is factory set and used when unique activation is required in areas where there are many interlocked doors and security of individual areas is required.
The MGL combines magnetic sensing and RFID technology to provide non contact operation and high anti-tamper coding. In addition an electromagnet is used to lock machine guards.
Only when the actuator is in the correct position can the lock be achieved and the safety outputs closed.
The switch provides two safe switching outputs for use with popular safety relays as well as a semi conductor auxiliary signal to indicate the door position.
There are 2 LEDs that offer 5 diagnostic functions to the user.
The switch is “Power to Lock” and therefore consideration must be given in the event of a power failure to machines where a run down time is present before the hazard is removed.
Approvals | ISO 14119, EN60204-1, ISO 13849-1, EN62061, UL 508, EN60947-5-3 |
---|---|
Cable length | 5 m |
Cable type | PVC 6 or 8 core 6mm OD |
Coding | Uniquely coded |
Contact type | 2NC safety outputs overload protected, 1NO auxiliary output for indication of door open |
Contacts | 2NC 1NO |
Holding force (F1Max) | 1100 N |
Housing material | Stainless steel 316 |
Integrated LED indication | Yes |
IP class | IP67, IP69K |
Mechanical reliability B10d | No mechanical parts implemented |
Mounting | 2 x M5 |
MTTFd | 1100a |
---|---|
Operating temperature | -25°C...+40°C |
PL | up to PLe |
Safety category | 4 |
SIL | up to SIL3 |
Solenoid Voltage | 24V dc |
Switching current min | 10V dc 1mA |
Switching distance | Sao 1mm close Sar 10mm open |
Switching frequency max | 1.0 Hz maximum |
Weight | 2600 g |
The MGL range of Non Contact RFID Coded switches has been developed in order to provide and maintain a high level of functional safety whilst providing a reliable magnetic door interlock.
Flexibility for holding force is provided by the provision of 2 different switch sizes - Heavy Duty (1100N (F1Max) Stainless Steel and Medium Duty (600N (F1Max) Stainless Steel to cover all applications.
Coding is achieved by using magnetic and RFID techniques and both principles need to be satisfied for the switch to operate safely.
The MGL range will connect to the majority of popular standard safety relays to achieve up to PLe/Category 4 to ISO13849-1.
The Stainless Steel 316 version has been designed with a Stainless Steel magnet and IP69K rating making it suitable for CIP and SIP processes.
RFID coding options
The RFID coding is offered in two types and can be either coded by series or uniquely coded.
Type 1: Master Code - by series (any actuator will operate any switch) this is used when unique door activation is not required, but the benefit of RFID makes it virtually impossible to be overridden or by-passed by simple means.
Type 2: 32,000,000 Unique Codes - the switch is factory set and used when unique activation is required in areas where there are many interlocked doors and security of individual areas is required.
The MGL combines magnetic sensing and RFID technology to provide non contact operation and high anti-tamper coding. In addition an electromagnet is used to lock machine guards.
Only when the actuator is in the correct position can the lock be achieved and the safety outputs closed.
The switch provides two safe switching outputs for use with popular safety relays as well as a semi conductor auxiliary signal to indicate the door position.
There are 2 LEDs that offer 5 diagnostic functions to the user.
The switch is “Power to Lock” and therefore consideration must be given in the event of a power failure to machines where a run down time is present before the hazard is removed.
We’re thrilled to welcome Tony Maton, our new Sales Engineer at OEM Automatic! Tony brings a wealth of knowledge and expertise in industrial automation and machine safety
Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.
We are thrilled to announce the launch of IATECH, THe Industrial Automation Technology expo at Leicester Marriott Hotel on 23rd October. The ultimate platform for showcasing our extensive product range and broad business areas, featuring over 50 leading suppliers under one roof!
The specialist vehicle industry can include automotive and EV, heavy vehicles such as agriculture and rail, and marine. This email takes you through some of the various products we offer for specialist vehicle applications.
If you're looking for more speed and accuracy, this new contrast sensor will work for you.
Do you need help with the safety of your industrial doors, gates, or high-speed doors? Whether you require safety edges, light curtains, safety bumpers, or complete control systems, we can help.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Cable length | Coding | Holding force (F1Max) | Weight | Price | ||
---|---|---|---|---|---|---|---|
MGL-1SS-U 5m
Art:
462001
Copied
|
5 m
|
Uniquely coded
|
1100 N
|
2600 g
|
| ||
MGL-1SS-U 10m
Art:
462002
Copied
|
10 m
|
Uniquely coded
|
1100 N
|
|
| ||
MGL-1SS-U QC-M12
Art:
462003
Copied
|
0,25 m
|
Uniquely coded
|
1100 N
|
2600 g
|
| ||
MGL-1SS-M 5m
Art:
462004
Copied
|
5 m
|
Master coded
|
1100 N
|
|
| ||
MGL-1SS-M 10m
Art:
462005
Copied
|
10 m
|
Master coded
|
1100 N
|
|
| ||
MGL-1SS-M QC-M12
Art:
462006
Copied
|
0,25 m
|
Master coded
|
1100 N
|
|
| ||
MGL-2SS-U 5m
Art:
460001
Copied
|
5 m
|
Uniquely coded
|
600 N
|
1740 g
|
| ||
MGL-2SS-U 10m
Art:
460002
Copied
|
10 m
|
Uniquely coded
|
600 N
|
|
| ||
MGL-2SS-U QC-M12
Art:
460003
Copied
|
0,25 m
|
Uniquely coded
|
600 N
|
1500 g
|
| ||
MGL-2SS-M 5m
Art:
460004
Copied
|
5 m
|
Master coded
|
600 N
|
|
| ||
MGL-2SS-M 10m
Art:
460005
Copied
|
10 m
|
Master coded
|
600 N
|
|
| ||
MGL-2SS-M QC-M12
Art:
460006
Copied
|
0,25 m
|
Master coded
|
600 N
|
|
|
Select a variant in the list