TEKNOMEGA

2-4 POLE DISTRIBUTION BLOCKS

RPB & RPQ

The 2-4 pole Ω electrical distribution blocks from Teknomega are suitable for applications which range from 40 A to 160 A.

 

Technical Features include:

  • Brass conductors
  • Self-extinguishing insulating structure UL 94-V0
  • Insulation between phases
  • Easy fit on DIN rails
  • Galvanized steel screws included
  • Front removable protection screen (except RPQ1025)

 

Certifications

  • Compliant with Standards IEC 947-1 : Low voltage devices Part 1: general rules
  • Compliant with Standards IEC 947-7-1 : Low voltage devices Part 7: Auxiliary equipment Section One - Terminal boards for copper conductors

 

Read more
  • 40 A to 160 A.
  • Self-extinguishing insulating structure UL 94-V0
  • Insulation between phases
  • Brass conductors
Teknomega 2-4 pole distribution blocks RPG & RPQ

Eplan Logo, data portal for 3D drawings

To view Teknomega Products via ePlan see the link under 'downloadable resources' further down the page

Selected variant

Available in several variants

Selected variant

Technical data

General Data

Rated current 125 A
IP class IP20
Nominal insulation voltage 500 V
Short-circuit current resistance IPK (peak value) 20 kA
Short-circuit current resistance ICW over 1s 4,2 kA

Connection Data

Connections 15
Number of inputs A 1
Input A: diameter 9 mm
Input A: wire cross-section stranded, min. 10 mm²
Input A: wire cross-section stranded, max. 35 mm²
Input A: wire cross-section with wire-end ferrules, min. 10 mm²
Input A: wire cross-section with wire-end ferrules, max. 25 mm²
Input A: torque, min. 2 Nm
Input A: torque, max. 3 Nm
Number of outputs A 1
Output A: diameter 9 mm
Output A: wire cross-section stranded, min. 10 mm²
Output A: wire cross-section stranded, max. 35 mm²
Output A: wire cross-section stranded with wire-end ferrules, min. 10 mm²
Output A: wire cross-section stranded with wire-end ferrules, max. 25 mm²
Output A: torque, min. 2 Nm
Output A: torque, max. 3 Nm
Number of outputs B 11

*Invisible Heading*

Output B: diameter 5,5 mm
Output B: wire cross-section stranded, min. 2,5 mm²
Output B: wire cross-section stranded, max. 6 mm²
Output B: wire cross-section stranded with wire-end ferrules, min. 1,5 mm²
Output B: wire cross-section stranded with wire-end ferrules, max. 6 mm²
Output B: torque, min. 2 Nm
Output B: torque, max. 3 Nm
Number of outputs C 2
Output C: diameter 7,5 mm
Output C: wire cross-section stranded, min. 10 mm²
Output C: wire cross-section stranded, max. 25 mm²
Output C: wire cross-section stranded with wire-end ferrules, min. 6 mm²
Output C: wire cross-section stranded with wire-end ferrules, max. 16 mm²
Output C: torque, min. 2 Nm
Output C: torque, max. 3 Nm
Screw type Galvanized steel screws

Dimensions

Fix. Hole space 112 mm
Length (L) 132 mm
Height (H) 46 mm
Width (P) 51 mm

Additional Data

Pack size 1

Product description

The 2-4 pole Ω electrical distribution blocks from Teknomega are suitable for applications which range from 40 A to 160 A.

 

Technical Features include:

  • Brass conductors
  • Self-extinguishing insulating structure UL 94-V0
  • Insulation between phases
  • Easy fit on DIN rails
  • Galvanized steel screws included
  • Front removable protection screen (except RPQ1025)

 

Certifications

  • Compliant with Standards IEC 947-1 : Low voltage devices Part 1: general rules
  • Compliant with Standards IEC 947-7-1 : Low voltage devices Part 7: Auxiliary equipment Section One - Terminal boards for copper conductors

 

Accessories

Related

crouzet millenium slim on limited time discount
Product news

The smallest logic controller ever on limited time discount

The smallest logic controller by Crouzet is now 20% off for a limited time only! A powerhouse packed into just 17.5mm! Efficiency, adaptability, and seamless integration with free software.

11 questions to get the right signalling device with Auer Signal & OEM Automatic
Blog

11 questions to get the right signalling device – a whitepaper

Do you require signalling devices and beacons in your production process? Download our latest whitepaper!

bespoke solutions electricity meter control boxes
Case studies

Control Box Assembly for Industrial Electricity Metering - A case study

Here, our customer requires control boxes for electricity metering systems. We leveraged our expertise to deliver easy-to-install, ready-to-use assemblies. We look forward to creating more of these bespoke control boxes for our customer.

DC circuit protection PISA M and circuit breakers
Blog

Safeguard systems with DC circuit protection

This blog talks all things DC circuit protection including the key components: electronic circuit breakers, fuses and current monitoring devices. As well as how to choose the right protection.

IATECH, the industrial automation technology exhibition OEM automatic
Company news

Recap of IATECH

Did you get a chance to visit IATECH at The Leicester Marriott Hotel? We had over 33 exhibitors and 8 fantastic Tech Talks throughout the day, Read all about the day, here.

zoller and frohlich cable preparation machines
Product news Blog

Book your Cable Preparation Machinery Demo at OEM

To help experience the capabilities of Z+F machines first-hand, we provide an in-depth demonstration and workshop. These sessions will show the machines in action and allow you to understand their features and gain valuable insight into their operation and benefits.

Parts Rated current Nominal insulation voltage Short-circuit current resistance IPK (peak value) Short-circuit current resistance ICW over 1s Connections Input A: diameter Input A: wire cross-section stranded, min. Input A: wire cross-section stranded, max. Input A: wire cross-section with wire-end ferrules, min. Input A: wire cross-section with wire-end ferrules, max. Input A: torque, min. Input A: torque, max. Number of outputs A Output A: diameter Output A: wire cross-section stranded, min. Output A: wire cross-section stranded, max. Output A: wire cross-section stranded with wire-end ferrules, min. Output A: wire cross-section stranded with wire-end ferrules, max. Output A: torque, min. Output A: torque, max. Number of outputs B Output B: diameter Output B: wire cross-section stranded, min. Output B: wire cross-section stranded, max. Output B: wire cross-section stranded with wire-end ferrules, min. Output B: wire cross-section stranded with wire-end ferrules, max. Output B: torque, min. Output B: torque, max. Number of outputs C Output C: diameter Output C: wire cross-section stranded, min. Output C: wire cross-section stranded, max. Output C: wire cross-section stranded with wire-end ferrules, min. Output C: wire cross-section stranded with wire-end ferrules, max. Output C: torque, min. Output C: torque, max. Number of outputs D Output D: wire coss-section stranded, min Output D: wire cross-section stranded, max Output D: wire cross-section stranded with wire-end ferrules, min Output D: wire cross-section stranded with wire-end ferrules, max Output D: torque, min. Output D: torque, max Output D: diameter Fix. Hole space Length (L) Height (H) Width (P) Price
125 A
500 V
20 kA
4,2 kA
15
9 mm
10 mm²
35 mm²
10 mm²
25 mm²
2 Nm
3 Nm
1
9 mm
10 mm²
35 mm²
10 mm²
25 mm²
2 Nm
3 Nm
11
5,5 mm
2,5 mm²
6 mm²
1,5 mm²
6 mm²
2 Nm
3 Nm
2
7,5 mm
10 mm²
25 mm²
6 mm²
16 mm²
2 Nm
3 Nm
112 mm
132 mm
46 mm
51 mm
40 A
500 V
20 kA
4,2 kA
9
5,5 mm
2,5 mm²
6 mm²
1,5 mm²
6 mm²
2 Nm
3 Nm
1
5,5 mm
2,5 mm²
6 mm²
1,5 mm²
6 mm²
2 Nm
3 Nm
4
4 mm
1,5 mm²
4 mm²
1,5 mm²
4 mm²
2 Nm
3 Nm
3
3 mm
1,4 mm²
2,5 mm²
1,5 mm²
2,5 mm²
2 Nm
3 Nm
45 mm
66 mm
46 mm
51 mm
80 A
500 V
20 kA
4,5 kA
8
7,5 mm
10 mm²
25 mm²
6 mm²
16 mm²
2 Nm
3 Nm
5
4,5 mm
1,5 mm²
4 mm²
1,5 mm²
4 mm²
2 Nm
3 Nm
2
5 mm
1,5 mm²
4 mm²
1,5 mm²
4 mm²
2 Nm
3 Nm
45 mm
66 mm
46 mm
51 mm
125 A
500 V
20 kA
4,2 kA
7
9 mm
10 mm²
35 mm²
10 mm²
25 mm²
2 Nm
3 Nm
5
5,5 mm
2,5 mm²
6 mm²
1,5 mm²
6 mm²
2 Nm
3 Nm
1
7,5 mm
10 mm²
25 mm²
6 mm²
16 mm²
2 Nm
3 Nm
45 mm
66 mm
46 mm
51 mm
40 A
500 V
20 kA
4,5 kA
9
5,5 mm
2,5 mm²
6 mm²
1,5 mm²
6 mm²
2 Nm
3 Nm
1
5,5 mm
2,5 mm²
6 mm²
1,5 mm²
6 mm²
2 Nm
3 Nm
4
4 mm
1,5 mm²
4 mm²
1,5 mm²
4 mm²
2 Nm
3 Nm
3
3 mm
1,5 mm²
2,5 mm²
1,5 mm²
2,5 mm²
2 Nm
3 Nm
45 mm
66 mm
84 mm
50 mm
40 A
500 V
20 kA
4,5 kA
15
5,5 mm
2,5 mm²
6 mm²
1,5 mm²
6 mm²
2 Nm
3 Nm
1
5,5 mm
2,5 mm²
6 mm²
1,5 mm²
6 mm²
2 Nm
3 Nm
7
4 mm
1,5 mm²
4 mm²
1,5 mm²
4 mm²
2 Nm
3 Nm
6
3 mm
1,5 mm²
2,5 mm²
1,5 mm²
2,5 mm²
2 Nm
3 Nm
80 mm
100 mm
84 mm
50 mm
80 A
500 V
20 kA
4,2 kA
8
7,5 mm
10 mm²
25 mm²
6 mm²
16 mm²
2 Nm
3 Nm
5
4,5 mm
1,5 mm²
4 mm²
1,5 mm²
4 mm²
2 Nm
3 Nm
2
5 mm
1,5 mm²
4 mm²
1,5 mm²
4 mm²
2 Nm
3 Nm
45 mm
66 mm
84 mm
50 mm
80 A
500 V
20 kA
4,2 kA
13
7,5 mm
10 mm²
25 mm²
6 mm²
16 mm²
2 Nm
3 Nm
1
7,5 mm
10 mm²
25 mm²
6 mm²
16 mm²
2 Nm
3 Nm
8
4,5 mm
1,5 mm²
4 mm²
1,5 mm²
4 mm²
2 Nm
3 Nm
2
5 mm
1,5 mm²
4 mm²
1,5 mm²
4 mm²
2 Nm
3 Nm
1
4 mm²
10 mm²
2,5 mm²
6 mm²
2 Nm
3 Nm
6 mm
80 mm
100 mm
84 mm
50 mm
125 A
500 V
20 kA
4,2 kA
7
9 mm
10 mm²
35 mm²
10 mm²
25 mm²
2 Nm
3 Nm
5
5,5 mm
2,5 mm²
6 mm²
1,5 mm²
6 mm²
2 Nm
3 Nm
1
7,5 mm
10 mm²
25 mm²
6 mm²
16 mm²
2 Nm
3 Nm
45 mm
66 mm
84 mm
50 mm
125 A
500 V
20 kA
4,2 kA
11
9 mm
10 mm²
35 mm²
10 mm²
25 mm²
2 Nm
3 Nm
1
9 mm
10 mm²
35 mm²
10 mm²
25 mm²
2 Nm
3 Nm
2
7,5 mm
10 mm²
25 mm²
6 mm²
16 mm²
2 Nm
3 Nm
7
5,5 mm
2,5 mm²
6 mm²
1,5 mm²
6 mm²
2 Nm
3 Nm
80 mm
100 mm
84 mm
50 mm
125 A
500 V
20 kA
4,2 kA
15
9 mm
10 mm²
35 mm²
10 mm²
25 mm²
2 Nm
3 Nm
1
9 mm
10 mm²
35 mm²
10 mm²
25 mm²
2 Nm
3 Nm
2
7,5 mm
10 mm²
25 mm²
6 mm²
16 mm²
2 Nm
3 Nm
11
5,5 mm
2,5 mm²
6 mm²
1,5 mm²
6 mm²
2 Nm
3 Nm
112 mm
132 mm
84 mm
50 mm
100 A
690 V
24 kA
4,2 kA
8
8,5 mm
6 mm²
35 mm²
6 mm²
25 mm²
1,5 Nm
5
5,5 mm
1,5 mm²
6 mm²
1,5 mm²
6 mm²
0,8 Nm
2
6 mm
1,5 mm²
16 mm²
1,5 mm²
10 mm²
1,5 Nm
55 mm
98 mm
75 mm
49 mm

Selected variant

Select a variant in the list

Contact us
If you need any help, you can contact us in one of the following ways:
0116 284 9900
Send e-mail
Use live chat
Do you need help?
Logo

Cookie settings for OEM.CO.UK

Cookies help us improve your experience with us, so in order to be able to handle login information, offer you personalised content and for basic functionality of this website, we use some cookies.

We will never sell on any information about you. 

You can accept all cookies or personalise your cookies preferences, you can also change your cookie preferences at any time by visiting our contact page.

Necessary Cookies

These cookies are necessary for the website to work and can not be turned off in our systems. They are usually used only in response to actions you have taken in connection with a service request, for example when setting personal preferences, logging in or filling out a form.

Analysis and measurement cookies

These cookies allow us to count the number of visits and traffic sources so that we can measure and improve our website performance. They help us know which pages are more or less popular and how visitors navigate around the site. The information that these cookies collect is aggregated and therefore completely anonymous. If you do not allow these cookies, we do not know when you have visited our website.

Marketing cookies

These cookies can be added by our partners. They can use them to create a profile of you, based on your interests, to show you more relevant information. They do not store any personal information - only information about your browser and device. If you do not accept these cookies, you will have a more general and less customized user experience.